3
Power Supplies
GL Series: Single & Multi Output Switchers
The new GL series provides a broad range of AC/DC
power supply solutions that covers power ratings from 25
watts to 500 watts for use in various industrial and medical
applications requiring standard footprint size and very high
reliability.
These low-profile AC/DC switchers offer universal input
voltage with no switches or jumpers, ideal for higher volume
worldwide applications.
All models feature:
• Industry standard footprints
• Universal input
• Full power to 50°C
• High demonstrated MTBF
• Automatic overvoltage protection
• Overload protection
• Built-in EMI Filtering
• Extensive safety approvals
• Derated operation to 70°C
• ±2% regulation on main output
• 250 VA and higher VA size enclosed
• Two year limited warranty
Many models feature:
• EN61000-3-2 Compliance
• Supervisory outputs (5 V/12 V)
• Wide-adjustable floating 4
th
output
• Single wire current share
• Medical approvals
• Remote Sense
• Adjustable main output
• Power Fail and DC Good signals
• Wide-adjustable on single output models
Certifications and Compliances
•
- UL 60950-1
•
Certified, ITE
- CSA C22.2 CSA 60950-1
•
- IEC60950-1
Cover and Bracket Options
• Cover options can be ordered separately. They are
designed to simplify mechanical integration of the
power supplies into systems and add an extra measure
of electrical safety for service personnel.
• Bracket kits can be ordered separately for GL110 series
only. It is needed when the cover option is used.
148
UL 60950
E137632
CUL/CSA-C22.2
No. 234-M90
E137632
Cover and Bracket Options
Catalog Number
GLX40
GLX50
GLX60
GLX110-B
GLX110-C
GLX120
GLX140-C
GLX140-CF
GLX150-C
GLX17Q-C
GLX17S-C
GLX200
GLX250-CEF
GLX250-CF
Description
Enclosure kit for the GL20 and GL40
Enclosure kit for the GL50 and GL100-M
Enclosure kit for the GL60
Bracket kit for the GL110
Cover kit for the GL110
Enclosure kit for the GLS120 and GLQ120
Cover kit for the GLQ140
Cover with top fan kit for the GLQ140
Cover kit for the GL150
Cover kit for the quad output GL170
Cover kit for the single output GL170
Enclosure kit for the GL200-M
Cover end fan kit for the GL250
Cover with top fan kit for the GL250/350
Mating Connectors
• Can be ordered separately for units with Molex
connection
• Kits include mating housing and pins for input and output
connection
Mating Connectors
Catalog Number
70-841-008
70-841-007
70-841-008
70-841-020
70-841-012
70-841-017
70-841-009
70-841-010
70-841-015
70-841-016
70-841-005
70-841-011
70-841-024
Description
GLX40, GLX50 and GLX60 Mating Connector Kit
GLS110 Mating Connector Kit
GLQ110 Mating Connector Kit
GLS120 Mating Connector Kit
GLQ123 Mating Connector Kit
GLQ142 Mating Connector Kit
GLS150 Mating Connector Kit
GLQ150 Mating Connector Kit
GLQ170 Mating Connector Kit
GLS170 Mating Connector Kit
GLX250 Mating Connector Kit
GLS350 Mating Connector Kit
GLS500 Mating Connector Kit
Recognized Component, ITE
Contact
Technical Services
at
(800) 377-4384
with any questions.
Visit our website at www.solahd.com.
Power Supplies
Specifications
GL20, GL40
GL50
GL60, GL110
GLQ120,
GLS120
Input
Input
Voltage
1
Frequency
GL20: <15A peak
@ 115 Vac; <30A
peak @ 230 Vac,
cold start @ 25°C.
GL40: <18A peak
@ 115 Vac; <36A
peak @ 230 Vac,
cold start @ 25°C
85 - 264 Vac;
120 - 300 Vdc
90 - 264 Vac
127 - 300 Vdc
47-63 Hz , 400± 40 Hz
GLQ120:
38 A max., cold
start @ 25°C
38 A max, cold start @ 25°C
GLS120:
40A max., cold
start @ 25°C
GLQ120: 65%
typical at full
load. GLS120:
80% typical at
full load
85 - 264 Vac
120 - 300 Vdc
85 - 132 Vac
or 170 - 264 Vac
auto-selected.
220 - 300 Vdc
85 - 264 Vac; 120 - 300 Vdc
3
GL150
GL170
GL250,
GL350
GL500
GL140
85 - 264 Vac
47-63 Hz
GL250:
20 A max.,
cold start
@ 25°C.
GL350:
38 A max.,
cold start
@ 25°C.
Inrush
Current
<60A peak
@ 230 Vac,
cold start @ 25°C
<18A peak
@ 115 Vac,
<36 A peak
@ 230 Vac,
cold start @
25°C
50 A max.,
cold start
@ 25°C
Efficiency
70% typical
at full load
80% - 85%
typical
at full load
70% typical
at full load
75% typical at full load
85% typical
at full load,
nominal line
EMI/RFI
Non-medical:
<0.5mA
Medical: 275 µA
@ 50/60 Hz;
264 Vac input for
Class I; <0.25mA
@ 50/60 Hz;
264 Vac input for
Class II (for single
output only)
FCC Class B ; CISPR 22 Class B ; EN55022 Class B
GLQ120:
<1 mA
@ 50/60 Hz,
264 Vac input.
GLS120:
0.5mA
@ 50/60 Hz,
264 Vac input
Safety
Ground
Leakage
Current
Non-Medical:
<0.5 mA
Medical: < 75 µA
@ 50/60 Hz,
264 Vac input
Non-Medical:
<0.5 mA
Medical:
< 75µA
@ 50/60 Hz;
264 Vac input
1.0 mA
@ 50/60 Hz,
264 Vac input
<0.5 mA
@ 50/60 Hz,
264 Vac input
Non-Medical:
0.1 mA
Medical:
< 250 µA
1.0 mA
@ 50/60 Hz,
264 Vac input
<0.5 mA
@ 50/60 Hz,
264 Vac input
Non-Medical:
<0.5 mA
Medical:
<0.3mA
@ 50/60 Hz,
264 Vac input
Output
Power
Adjustment
Range on
Main Output
Hold-up
Time
Overload
5 V output; 5.7 to
6.7 Vdc. Other
outputs 10% to
25% above
nominal output
±20% minimum for
single output only
models
GL60: -5,
+10% minimum
GL110: ±5%
on main, 5-25 V
on 4
th
output
Refer to the selection table
3.3 - 5.5V on
main; -12 -
15V on 3rd
output 3.3 -
25 V on 4th
output
-5, +10%
minimum
±5% minimum
±5% minimum
on main, 5-25 V
on 4
th
output
2:1 wide
ratio
minimum
2:1 wide ratio
±5%
20 ms @ full load,
115 Vac nominal line
10/20 ms 115/230
Vac Input line
20 ms @ full load, 115 Vac nominal line
Short circuit protection on all outputs. Primary overload protection
5 V output; 5.7
- 6.7 Vdc. Other
outputs 10%
to 25% above
nominal output
3.3 V and 5 V
output: 20% to
35%
above nominal
output
5 V output: 5.7
to 6.7 Vdc.
Other out-
puts10% to 25%
above nominal
output
10% to 40%
above
nominal
output
5 V output: 5.7
to 6.7 Vdc.
Other outputs
10% to 25%
above
nominal output
20-35%
above
nominal
output
Overvoltage
Protection
30-50% above
nominal output
Tracks out-
puts 1, 3 & 4;
10 to 35%
Remote Sense
Compensates for 0.5 V lead drop minimum; Will operate without remote sense connected, Reverse connection protected
General
Temperature
2
Electro-
magnetic
Susceptibility
Humidity
Vibration
MTBF
Safety
Storage:
-40°C to +85°C;
Operating:
0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up.
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Operating; non-condensing up to 95% RH
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz
(2 G peak 8 Hz to 500 Hz for GL500)
>550,000 hours demonstrated at full load and 25°C ambient conditions
Non-Medical: EN60950, UL UL60950 E132002, CSA CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD)
Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-1
Notes:
1. Proper circuit protection required when operating with a DC input voltage. 2. Regulation and ripple may deviate from the spec at -20°C start up.
Contact
Technical Services
at
(800) 377-4384
with any questions.
Visit our website at www.solahd.com.
149
3
Selection Table
Catalog
Number
GLS22
GLS23
GL20
[40 W] 25 W
GLS24
GLT22
GLT23
GLT24
GLT25
GLS42
4
GLS43
4
GLS44
4
GL40
[55 W] 40 W
1
[40 W] 25 W
2
GLS45
4
GLT42
4
GLT43
GLT44
GLT45
4
GLT46
GL50
[50 W] 50 W
GLT52
4
GLT53
4
GLT54
4
GLS52
4
GLS53-I
5
GL50
[60 W] 60 W
GLS53
4
GLS54
4
GLS55
4
GLS58
4
GLS62
GLS63
4
GLS64
4
GL60
[80 W] 60 W
1
[60 W] 40 W
2
GLS65
4
GLT62
4
GLT63
4
GLT64
GLT65
GLS114
GL110
[110 W] 80 W
1
[90 W] 70 W
2
GLS115
GLQ112
GLQ113
GLQ114
Output 1
5 V @ 5 A [8 A]
6
12 V @ 2.1 A [3.3 A]
6
15 V @ 1.7 A [2.7]
6
5 V @ 3 A [4 A]
7
5 V @ 4 A [5 A]
7
5 V @ 3 A [4 A]
7
5 V @ 3 A [4 A]
7
5 V @ 8 A [11 A]
6
12 V @ 3.3 A [4.5]
6
15 V @ 2.6 A [3.6 A]
6
24 V @ 1.6 A [2.3 A]
6
5 V @ 4 A [5 A]
7
5 V @ 6 A [8 A]
7
5 V @ 4 A [5 A]
7
5 V @ 4 A [5 A]
7
5 V @ 4 A [5 A]
7
5V@8A
7
5V@8A
7
5V@8A
7
5 V @ 11 A
12 V @ 5A
12 V @ 5 A
6
15 V @ 4 A
6
24 V @ 2.5 A
6
48 V @ 1.25 A
6
5 V @12 A [16 A]
6
12 V @ 5 A [6.7 A]
6
15 V @ 4 A [5.3 A]
6
24 V @ 2.5 A [3.3 A]
6
5 V @ 7 A [8 A]
7
5 V @ 7 A [8 A]
7
5 V @ 7 A [8 A]
7
5 V @ 7 A [8 A]
7
15 V @ 5.3 A [7.3 A]
6
24 V @ 3.3 A [4.6 A]
6
5 V @ 9 A [11 A]
8
5 V @ 9 A [11 A]
8
5 V @ 9 A [11 A]
8
Power Supplies
Output 2
-
-
-
12 V @ 1.5 A [2 A]
7
12 V @ 0.5 A [0.7 A]
12 V @ 1.5 A [2 A]
7
15 V @ 1.5 A [2 A]
7
-
-
-
-
12 V @ 2 A [2.5 A]
7
12 V @ 0.5 A [0.7 A]
12 V @ 2 A [2.5 A]
7
15 V @ 2 A [2.5 A]
7
24 V @ 1 A [1.5 A]
7
12 V @ 3 A
7
15 V @ 2.4 A
7
24 V @ 1.5 A
7
-
-
-
-
-
-
-
-
-
-
12 V @ 3 A [3.5 A]
7
15 V @ 2.8 A [3.3 A]
7
12 V @ 3 A [3.5 A]
7
24 V @ 1.5 A [2 A]
7
-
-
12 V @ 4.5 A [5 A}
15 V @4.5 A [5 A]
12 V @ 4.5 A [5 A]
Output 3
-
-
-
-12 V @ 0.5 A [0.7 A]
-12 V @ 0.5 A [0.7 A]
-5 V @ 0.5 A [0.7 A]
-15 V @ 0.5 A [0.7 A]
-
-
-
-
-12 V @ 0.5 A [0.7 A]
-12 V @ 0.5 A [0.7 A]
-5 V @ 0.5 A [0.7 A]
-15 V @ 0.5 A [0.7 A]
+12 V @ 0.5 A [0.7 A]
-12 V @ 0.5 A
-15 V @ 0.5 A
12 V @ 0.5 A
-
-
-
-
-
-
-
-
-
-
-12 V @ 0.7 A [1 A]
-15 V @ 0.7 A [1 A]
-5 V @ 0.7 A [1 A]
+12 V @ 0.7 A [1 A]
-
-
-12 V @ 0.7 A [1 A]
-15 V @ 0.7 A [1 A]
-12 V @ 0.7 A [1 A]
Output 4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
±5-25 V @ 2.5 A [3 A]
6
±5-25 V @ 2.5 A [3 A]
6
24 V @ 3.5 A [4.5 A]
8
Case
3
Pin
Assignments
3
1A
Mating
Connectors
3
1
2A
1B
3A
1
1B
4A
2
5A
2B
3
6A
2B
7A
3B
4
8A
4B
9A
5
10A
5B
6B
Notes:
[ ] Rating with 30 CFM of air
1. Power rating when no cover option is used
2. Power rating when the cover/enclosure option is used
3. Refer to GL Series Dimensions and the sections that follow
4. Add “-M” suffix for the medical model numbers
5. Industrial version - Operating temperature -40°C to 80°C
6. Floating output
7. Approximate minimum loading: 10%
8. Approximate minimum loading: 23%
150
Contact
Technical Services
at
(800) 377-4384
with any questions.
Visit our website at www.solahd.com.
Power Supplies
Selection Table (continued)
Catalog
Number
GLQ120
[120 W] 70 W
GLS120
[130 W] 80 W
GL140
[145 W] 80 W
GLQ123
GLS122
GLS123
GLQ142
3
Output 4
-12 V @ 0.5 A [1 A]
-
7
12A
8B
-
±3.3-25 V @ 1.5 A
[4.5 A]
8 10
-
-
-
9
14A
10B
8
13A
9B
Output 1
3.3 V @ 14 A [25 A]
5 V @ 16 A [26 A]
8
12 V @ 6.6 A [10.8 A]
8
5 V @ 12 A [25 A]
(3.3 V - 5 V)
5 V @ 22 A [30 A]
8
12 V @ 9.1 A [12.5 A]
8
(12 V- 15 V)
24 V @ 4.5 A [6.2 A]
8
(24 V - 28 V)
5 V @ 15 A [22 A]
9
5 V @ 15 A [22 A]
9
5 V @ 15 A [22 A]
9
5 V @ 22 A [35 A]
8
(2.5 V - 6 V)
12 V @ 9.1 A [15 A]
8
(6 V- 12 V)
15 V @ 7.3 A [12 A]
8
(12 V - 24 V)
24 V @ 4.5 A [7.5]
8
(24 V - 54 V)
5 V @ 15 A [30 A]
(3.3 V - 5.5 V)
12 V (6-12 V) @ [21 A]
24 V (24-48) @ [10.4 A]
8
5 V @ [35 A]
11
5 V @ [35 A]
11
5 V (3-6 V) @ [70 A]
12 V (6-12 V)
@ [29.2 A]
8
15 V (12-24 V)
@ [23.3 A]
8
24 V (24-48 V)
@ [14.6 A]
8
24 V (24-48 V)
@ [14.6 A]
8
5 V @ [50 A]
11
5 V @ [50 A]
11
12 V @ 16.6 A [41.7 A]
24 V @ 8.3 A [20.8 A]
48 V @ 4.2 A [10.4 A]
Output 2
5 V @ 12.5 A [24 A]
9
-
-
12 V @ 5 A [6 A]
-
-
-
12 V @ 2.6 A [8 A]
11
15 V @ 4.8 A [6.4 A]
11
12 V @ 6 A [8 A]
11
-
-
-
-
12 V @ 6 A [8 A]
10
-
-
12 V @ [10 A]
15 V @ [10 A]
-
-
-
-
-
12 V @ [12 A]
12 V @ [12 A]
-
-
-
Output 3
+12 V @ 1 A [2 A]
-
-
-12 V @ 1 A [1.5 A]
(-12 V - 15 V)
-
-
-
-12 V @ 2 A [2.5 A]
11
-15 V @ 1.6 A [2 A]
11
-12 V @ 2 A [2.5 A]
11
-
-
-
-
-12 V @ 0.2 A [3 A]
(-12 V - 15 V)
-
-
-12 V @ [6 A]
-15 V @ [6A]
-
-
-
-
-
-12 V @ [6 A]
-12 V @ [6 A]
-
-
-
Case
5
6
Pin
Mating
Assignments
5
Connectors
5
11A
7B
GLS152
GLS153
GL150
[150 W] 110 W
1
[130 W] 75 W
2
GLS155
GLQ152
GLQ153
GLQ154
GLS172
6
GLS173
6
GL170
[175 W] 110 W
1
[130 W] 75 W
2
GLS174
6
GLS175
6
GLQ172
GLS253-C
GL250
[250 W]
3 4
GLS255-C
GLQ252-C
GLQ253-C
GLS352-C
GLS353-C
GLS354-C
GL350
[350 W]
3 4
GLS355-C
GLS355-CEF
GLQ352-C
GLQ352-CEF
GLS503-CF
7
GL500
[500 W] 200 W
Notes:
[ ] Rating with 30 CFM of air
GLS505-CF
7
GLS508-CF
7
±5-25 V @ 2.5 A [3 A]
8
±5-25 V @ 2.5 A [3 A]
8
24 V @ 3.5 A [4.5 A]
9
-
-
11
-
-
±3.3-25 V @ 2 A [5 A]
8
-
13
-
±5-25 V @ [6 A]
8
±5-25 V @ [6 A]
8
-
-
-
-
-
±3.3-24 V @ [6 A]
8
±3.3-24 V @ [6 A]
8
-
-
-
17
22A
17B
16
21A
16B
14
19A
18A
14B
12
17A
13B
16A
12B
10
15A
11B
15
20A
15B
6. Add “-M” suffix for the medical models numbers.
7. Insert (-M) as in GLS 50x-M-CF for medical model numbers
8. Floating output
9. Approximate minimum loading: 16%
10. Approximate minimum loading: 30%
11. Approximate minimum loading: 10%
1. Power rating when no cover option is used
2. Power rating when the cover/enclosure option is used
3. Optional fan cover, See Table 1
4. Optional end fan cover, See Table 1
5. Refer to GL Series Dimensions and the sections that follow
Contact
Technical Services
at
(800) 377-4384
with any questions.
Visit our website at www.solahd.com.
151
3
GL Series Dimensions
Power Supplies
(Weight: 0.5 lbs/0.23 kg approx.)
Case 1
(Weight: 0.45 lbs/0.20 kg approx.)
Case 2
(Weight: 0.41 lbs/0.18 kg approx.)
Case 3
(Weight: 0.75 lbs/0.34 kg approx.)
Case 4
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5 mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 Vac input, 25°C unless otherwise stated.
152
Contact
Technical Services
at
(800) 377-4384
with any questions.
Visit our website at www.solahd.com.