VRA_(X)D-10WR2 & VRB_(X)D-10WR2 series products are of 10W output power, extremely wide range of voltage input of 9-18VDC,
18-36VDC,
36-75VDC
isolation voltage of 1500VDC, output over-voltage protection and output short circuit protection with the bare
component in compliance with CISPR22/EN55022 CLASS A; these products are widely used in fields such as industrial control, electric power,
instruments and communication.
Selection Guide
Input Voltage(VDC)
Part No.
①
Output
②
Nominal
(Range)
Max.
Output Voltage
(VDC)
±5
±12
±15
±24
Output Current
(mA)
(Max./Min.)
±1000/±50
±416/±21
±333/±16
±208/±10
2400/120
2000/100
833/42
667/33
416/21
±1000/±50
±416/±21
±333/±16
±208/±10
2400/120
2000/100
833/42
667/33
416/21
±1000/±50
±416/±21
±333/±16
±208/±10
2400/120
2000/100
833/42
Efficiency
③
(%,Typ.)
@ Full Load
82
86
87
87
77
82
86
87
88
83
86
88
87
77
84
88
90
87
83
88
89
88
78
82
88
Max.
Capacitive
④
Load
(μF)
680
220
100
47
2200
2200
470
220
100
680
330
220
100
2200
2200
680
330
100
680
470
220
100
2200
2200
820
certification
VRA1205(X)D-10WR2
VRA1212(X)D-10WR2
VRA1215(X)D-10WR2
VRA1224(X)D-10WR2
VRB1203(X)D-10WR2
VRB1205(X)D-10WR2
VRB1212(X)D-10WR2
VRB1215(X)D-10WR2
VRB1224(X)D-10WR2
VRA2405(X)D-10WR2
VRA2412(X)D-10WR2
VRA2415(X)D-10WR2
VRA2424(X)D-10WR2
VRB2403(X)D-10WR2
VRB2405(X)D-10WR2
VRB2412(X)D-10WR2
VRB2415(X)D-10WR2
VRB2424(X)D-10WR2
VRA4805(X)D-10WR2
VRA4812(X)D-10WR2
VRA4815(X)D-10WR2
VRA4824(X)D-10WR2
VRB4803(X)D-10WR2
VRB4805(X)D-10WR2
VRB4812(X)D-10WR2
48V
( 36-75)
80
24V
(18-36)
40
12V
(9-18)
20
3.3
5
12
15
24
±5
±12
±15
±24
3.3
5
12
15
24
±5
±12
±15
±24
3.3
5
12
CE
CE
CE
CE
CE
CE
CE
CE
CE
CE
CE
CE
2014.03.27-B/0
Page 1 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
VRA_(X)D-10WR2 & VRB_(X)D-10WR2 Series
Selection Guide
Input Voltage(VDC)
Part No.
①
Output
②
Nominal
(Range)
48V
( 36-75)
Max.
80
Output Voltage
(VDC)
15
24
Output Current
(mA)
(Max./Min.)
667/33
416/21
Efficiency
③
(%,Typ.)
@ Full Load
89
88
Max.
Capacitive
④
Load
(μF)
470
220
certification
VRB4815(X)D-10WR2
VRB4824(X)D-10WR2
CE
Note:
①."X"
means the model without Ctrl pin, series with suffix "A2S" are chassis mounting, with suffix "A4S" are DIN-Rail mounting, for example VRB2405XD-10WR2A2S is
chassis mounting without Ctrl pin,VRB2405D-10WR2A4S is DIN-Rail mounting with Ctrl pin.
②.Absolute
maximum rating without damage on the converter, but it isn't recommended.
③.The
efficiency of "A2S" and "A4S" is approx. 2% lower for the protection of inverse polarity.
④.For
dual output converter, the given value is the same for each output.
Input Specifications
Item
Input Current (full load / no-load)
Operating Conditions
12VDC input
24VDC input
48VDC input
12VDC input
Min.
--
--
--
--
--
--
-0.7
-0.7
-0.7
--
--
--
Typ.
25/1016
12/496
6/254
20
20
20
--
--
--
--
--
--
Pi filter
Max.
--
--
--
--
--
--
25
50
100
9
18
36
Unit
mA
Reflected Ripple Current
24VDC input
48VDC input
12VDC input
Input impulse Voltage (1sec. max.)
24VDC input
48VDC input
12VDC input
VDC
Starting Voltage
Input Filter
24VDC input
48VDC input
Module switch on
Ctrl suspended or connected to TTL high level (3.5-12VDC)
Ctrl pin connected to GND or low level (0-1.2VDC)
--
1
3
mA
Ctrl*
Module switch off
Input current when switched off
Note: * the voltage of Ctrl pin is relative to input pin GND.
Output Specifications
Item
Output Voltage Accuracy
Balance of Output Voltage
Line Regulation
Load Regulation
Cross Regulation
Transient Recovery Time
Transient Response Deviation
Temperature Drift Coefficient
Ripple*
Noise*
Output Over-voltage Protection
Short circuit Protection
Dual output, balanced load
Full load, the input voltage is from low voltage to
high voltage
5%-100% load
Dual output, main circuit with 50% load,
auxiliary circuit with 10%-100% load
25% load step change
Full load
20MHz bandwidth
Input voltage range
Operating Conditions
Min.
--
--
--
--
--
--
--
--
--
--
110
Typ.
±1
±0.5
±0.2
±0.5
--
300
±3
--
15
40
120
Max.
±2
±1.5
±0.5
±1
±5
500
±5
±0.03
35
80
140
Unit
%
μs
%
%/
°
C
mV p-p
%Vo
Continuous, self-recovery
Note: * Ripple and noise tested with “parallel cable” method, please see
DC-DC Converter Application Notes
for specific operation methods.
2014.03.27-B/0
Page 2 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
VRA_(X)D-10WR2 & VRB_(X)D-10WR2 Series
General Specifications
Item
Insulation Voltage
Insulation Resistance
Isolation Capacitance
Operating Temperature
Storage Humidity
Storage Temperature
Max. Operating Temperature
for Casing
Pin Welding Resistance
Temperature
Vibration
Switching Frequency
MTBF
PWM mode
MIL-HDBK-217F@25°C
--
1000
Within the operating temperature curve
Welding spot is 1.5mm away from the casing, 10
seconds
Operating Conditions
Input-output, with the test time of 1 minute and the
leak current lower than 1mA
Input-output, insulation voltage 500VDC
Input-output, 100KHz/0.1V
Derating if the temperature is
≥71°C
(see Fig. 1)*
Non-condensing
Min.
1500
1000
--
-40
5
-55
--
--
Typ.
--
--
1000
--
--
--
--
--
Max.
--
--
--
85
95
125
105
300
°C
Unit
VDC
MΩ
pF
%
10-55Hz, 10G, 30 Min. along X, Y and Z
350
--
--
--
KHz
K hours
Note: * VRB1205 (X) D-10WR2 temperature derating to 65