12W Single Output LED Power Supply
PLM-12
series
M
M
110
SELV
IP30
(for Blank type only)
18
S&E
(for E type only)
■
Features
230VAC only or Full range (up to 295VAC)
models available
Built-in active PFC function
Constant current design
Protections:Short circuit
Cooling by free air convection
Fully isolated plastic case
Class
Ⅱ
power unit, no FG
Class 2 power unit (Blank type only)
No load power consumption <0.5W
High reliability,low cost
2 years warranty
■
Applications
Indoor LED lighting
LED office lighting
LED commercial lighting
LED decorative lighting
■
Description
PLM-12 is a 12W economical AC/DC LED power supply series. Incorporating a built-in active PFC
design, PLM-12 provides a high Power Factor value greater than 0.9. In addition, with the low no load
power consumption below 0.5W, and the setup time less than 500ms, PLM-12 is complied with the ErP
regulation required by European Union for lighting fixtures.
PLM-12 is a class
Ⅱ
(without FG pin) power unit housed with the UL 94V-0 rated flame retardant
plastic case. The
I
/O terminals are designed with screw-less clamp style terminal block that greatly
simplifies the wiring installation. Two types of models with different input voltage range are offered:
PLM-12 series, which operates from 110~295VAC, and PLM-12E series, which operates from
180~295VAC.These two series are both constant current output design, supplying models with the
current of 350mA, 500mA, 700mA and 1050mA, respectively.
■
Model Encoding
PLM - 12 E - 350
{
E:AC input range 180~295VAC
Output wattage
Series name
Output current
Blank: AC input range 110~295VAC
File Name:PLM-12-SPEC 2018-01-10
12W Single Output LED Power Supply
SPECIFICATION
MODEL
PLM-12
CONSTANT CURRENT REGION
Note.5
22 ~ 36V
RATED CURRENT
RATED POWER
0.35A
12.6W
NO LOAD OUTPUT VOLTAGE
(max.)
42V
OUTPUT
RIPPLE & NOISE Blank type
3.6Vp-p
(max.)
Note.2
E type
5.5Vp-p
CURRENT ACCURACY
Note.3
±5.0%
SETUP TIME
VOLTAGE RANGE
Note.4
PLM-12
-500
PLM-12
11 ~ 18V
0.7A
22V
12.6W
2.4Vp-p
3.6Vp-p
-700
PLM-12
7 ~ 12V
1.05A
16V
12.6W
1.8Vp-p
2.7Vp-p
series
-350
PLM-12
15 ~ 24V
0.5A
30V
12W
2.4Vp-p
3.6Vp-p
-1050
Blank type: 500ms / 115VAC, 230VAC at full load;
Blank type: 110 ~ 295VAC
47 ~ 63Hz
E type: 500ms / 230VAC at full load
254~ 417VDC
156 ~ 417VDC; E type: 180 ~ 295VAC
FREQUENCY RANGE
POWER FACTOR
E type
Blank type
PF
≥
0.97/115VAC,PF
≥
0.95/230VAC,PF>0.9/277VAC(at full load)(Please refer to "Power Factor Characteristic" curve)
PF
≥
0.95/230VAC,PF
≥
0.9/277VAC (at full load)(Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC Blank type
THD< 20% when output loading
≧
60% at 115VAC/230VAC input and output loading
≧
75% at 277VAC input
DISTORTION
E type
THD< 20% when output loading
≧
60% at 230VAC input and output loading
≧
75% at 277VAC input
INPUT
EFFICIENCY
(Typ.)
AC CURRENT
INRUSH CURRENT(Typ.)
Blank type
85%
E type
84%
Blank type: 0.15A/115VAC
84%
83%
0.08A/230VAC
83%
82%
81%
78%
0.07A/277VAC; E type: 0.08A/230VAC 0.07A/277VAC
COLD START 15A(twidth=50
μ
s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
160 units (circuit breaker of type B) / 160 units (circuit breaker of type C) at 230VAC
CIRCUIT BREAKER
LEAKAGE CURRENT
PROTECTION
SHORT CIRCUIT
0.25mA / 240VAC
Hiccup mode, recovers automatically after fault condition is removed.
-30 ~ +50℃
20 ~ 90% RH non-condensing
±
0.06%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.13-12(for Blank type only); ENEC EN61347-1, EN61347-2-13, EN62384,
GB19510.14,GB19510.1(for E type only),EAC TP TC 004,IP30 approved
WORKING TEMP.
WORKING HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +80
℃
, 10 ~ 95% RH
I/P-O/P:3.75KVAC
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
I/P-O/P:100M Ohms/500VDC / 25
℃
/ 70%RH
EMC
Compliance to EN55015, GB17743, GB17625.1(for E type only),EN61000-3-2 Class C(
≥
60% load);EN61000-3-3,EAC TP TC 020
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61547, light industry level, criteria B(surge 2KV),EAC TP TC 020
808.162Khrs min.
MIL-HDBK-217F (25
℃
)
145*38*22mm (L*W*H)
0.126Kg;60pcs/8.6 Kg/0.48CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Please see
"
input voltage drop vs. output current characteristics
"
table.
AC
4. Derating may be needed under low input voltage, please check the static characteristic for more details.
5. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLM-12-SPEC 2018-01-10