Medline PMP03 Series
3.3W 2:1 & 4:1 SINGLE OUTPUT MEDICAL DC/DC CONVERTER
Specifications
INPUT
Voltage range
5Vin(nom)
4.5-9VDC
12Vin(nom)
9-18VDC
24Vin(nom)
18-36VDC
48Vin(nom)
36-75VDC
4:1 (W) 24V(nom)
9-36VDC
48V(nom)
18-75VDC
2:1
5Vin(nom)
4.5VDC
12Vin(nom)
9VDC
24Vin(nom)
18VDC
48Vin(nom)
36VDC
4:1 (W) 24V(nom)
9VDC
48V(nom)
18VDC
2:1
5Vin(nom)
4VDC
12Vin(nom)
8VDC
24Vin(nom)
16VDC
48Vin(nom)
33VDC
4:1 (W) 24V(nom)
8VDC
48V(nom)
16VDC
3 seconds max.
2:1
5Vin(nom)
16VDC
12Vin(nom)
25VDC
24Vin(nom)
50VDC
48Vin(nom)
100VDC
4:1 (W) 24V(nom)
50VDC
48V(nom)
100VDC
Pi type.
Referenced to -INPUT pin
(only for B-type pin connection option)
DC-DC ON
Open or 0~1.2VDC
DC-DC OFF
2.2~12VDC
Input current of CTRL pin -0.5 min, 1mA max
Remote off input current 2.5mA
2:1
Start-up voltage
Features
• Reinforced insulation for 300VAC working voltage
• Clearance and creepage distance: 6.6mm/2MOOP
• 3000VAC input to output 2MOOP isolation
• Built-in EMI Class A filter
• 2μA patient leakage current
• Safety meets ANSI/AAMI ES60601-1, EN60601-1
and IEC60601-1
• CE mark meets 2006/95/EC, 2011/95/EC
and 2004/108/EC
• Compliant to RoHs EU Directive 2011/65/EU
ENVIRONMENTAL
Operating ambient temp. –40°C to +94°C without derating.
+94°C to +105°C with derating.
Storage temperature
–55°C to +125°C.
Thermal impedance
18°C/W natrual convection (20LFM).
Thermal shock
MIL-STD-810F.
Vibration
MIL-STD-810F.
Relative humidity
5-95% RH.
GENERAL
Isolation voltage
Isolation capacitance
Leakage current
Switching frequency
Clearance/creepage
Case material
Base material
Potting material
Dimensions
Weight
MTBF
STANDARDS
Safety standards
EMC performance
EMI
1
ESD
Radiated immunity
Fast transient
2
Surge
2
Conducted immunity
Input to output 3000VAC, 1 minute.
12pF typ.
2mA max at 240VAC, 60Hz.
100KHz typ.
6.6mm.
Non-conductive black plastic.
Non-conductive black plastic.
Silicon (UL94-V0).
31.8 x 20.3 x 10.2 mm.
14g.
1.303 x 10
6
hrs, MIL-HDBK-217F, 25°C, full load.
ANSI/AAMI ES60601-1, IEC60601-1, EN60601-1.
EN55011, EN55022 and FCC Part 18.
EN61000-4-2 Air ±8kV Contact ±6kV Criteria A
EN61000-4-3 10V/m
Criteria A
EN61000-4-4 ±2KV
Criteria A
EN61000-4-5 ±2KV
Criteria A
EN61000-4-6 10Vrms
Criteria A
20130521
Shutdown voltage
Input surge voltage
Input filter
Remote On/Off
OUTPUT
Voltage accuracy
Line regulation
Load regulation
Cross regulation (dual)
Voltage adjustability
±1%.
±0.2%, low line to high line at full load.
±0.5%, no load to full load.
±5.0%, assymetrical load 25%/100% FL.
(only for B-type pin connection option)
Single: 3.3, 5, 12Vout
–10/+10%
15, 24Vout
–10/+20%
Dual: ±5, ±12, ±15Vout –10/+10%
Ripple and noise
Measured by 20MHz bandwidth with a
10mF/25V X7R MLCC:
3.3, 5Vout
30mV p-p
12, 15Vout
40mV p-p
Measured by 20MHz bandwidth with a
47mF/50V X7R MLCC:
24Vout
50mV p-p
Temperature coefficient ±0.02%/ °C.
Transient response
250ms recovery time at 25% load step change.
Over voltage protection 3.3Vout
3.7~5.4 VDC
5Vout
5.6~7.0 VDC
12Vout
13.5~19.6 VDC
15Vout
18.3~22.0 VDC
24Vout
29.1~32.5 VDC
Over load protection
150% of Iout rated; hiccip mode.
Short circuit protection Continuous, automatics recovery.
MEDLINE
www.powerbox.info
Medline PMP03 Series
3.3W 2:1 & 4:1 SINGLE OUTPUT MEDICAL DC/DC CONVERTER
MODEL
NUMBER
INPUT
RANGE
4.5 ~9 VDC
4.5 ~9 VDC
4.5 ~9 VDC
4.5 ~9 VDC
4.5 ~9 VDC
4.5 ~9 VDC
4.5 ~9 VDC
4.5 ~9 VDC
9 ~ 18 VDC
9 ~ 18 VDC
9 ~ 18 VDC
9 ~ 18 VDC
9 ~ 18 VDC
9 ~ 18 VDC
9 ~ 18 VDC
9 ~ 18 VDC
18 ~ 36 VDC
18 ~ 36 VDC
18 ~ 36 VDC
18 ~ 36 VDC
18 ~ 36 VDC
18 ~ 36 VDC
18 ~ 36 VDC
18 ~ 36 VDC
36 ~ 75 VDC
36 ~ 75 VDC
36 ~ 75 VDC
36 ~ 75 VDC
36 ~ 75 VDC
36 ~ 75 VDC
36 ~ 75 VDC
36 ~ 75 VDC
OUTPUT
VOLTAGE
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±12 VDC
±15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±12 VDC
±15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±12 VDC
±15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±12 VDC
±15 VDC
OUPUT CURRENT
@ FULL LOAD
1000 mA
600 mA
250 mA
200 mA
125 mA
±300 mA
±125 mA
±100 mA
1000 mA
600 mA
250 mA
200 mA
125 mA
±300 mA
±125 mA
±100 mA
1000 mA
600 mA
250 mA
200 mA
125 mA
±300 mA
±125 mA
±100 mA
1000 mA
600 mA
250 mA
200 mA
125 mA
±300 mA
±125 mA
±100 mA
INPUT CURRENT
@ NO LOAD
10 mA
10 mA
15 mA
15 mA
20 mA
25 mA
25 mA
25 mA
10 mA
10 mA
10 mA
10 mA
10 mA
10 mA
10 mA
10 mA
6 mA
6 mA
6 mA
6 mA
6 mA
6 mA
6 mA
6 mA
4 mA
4 mA
4 mA
4 mA
4 mA
4 mA
4 mA
4 mA
EFFICIENCY
MAX
PMP03
CAPACITOR LOAD
81%
84.5%
85%
85%
85.5%
83%
86%
86%
82%
84.5%
86%
87%
87%
82%
87%
86%
82%
84.5%
87%
87%
87%
83%
86.5%
86%
81%
83%
86.5%
87%
86%
83%
86%
86%
1050
mF
750
mF
130
mF
100
mF
39
mF
± 430
mF
± 75
mF
± 56
mF
1050
mF
750
mF
130
mF
100
mF
39
mF
± 430
mF
± 75
mF
± 56
mF
1050
mF
750
mF
130
mF
100
mF
39
mF
± 430
mF
± 75
mF
± 56
mF
1050
mF
750
mF
130
mF
100
mF
39
mF
± 430
mF
± 75
mF
± 56
mF
PMP03-05S3P3A/B
PMP03-05S05A/B
PMP03-05S12A/B
PMP03-05S15A/B
PMP03-05S24A/B
PMP03-05D05A/B
PMP03-05D12A/B
PMP03-05D15A/B
PMP03-12S3P3A/B
PMP03-12S05A/B
PMP03-12S12A/B
PMP03-12S15A/B
PMP03-12S24A/B
PMP03-12D05A/B
PMP03-12D12A/B
PMP03-12D15A/B
PMP03-24S3P3A/B
PMP03-24S05A/B
PMP03-24S12A/B
PMP03-24S15A/B
PMP03-24S24A/B
PMP03-24D05A/B
PMP03-24D12A/B
PMP03-24D15A/B
PMP03-48S3P3A/B
PMP03-48S05A/B
PMP03-48S12A/B
PMP03-48S15A/B
PMP03-48S24A/B
PMP03-48D05A/B
PMP03-48D12A/B
PMP03-48D15A/B
PMP03(W)
PMP03-24S3P3WA/B
PMP03-24S05WA/B
PMP03-24S12WA/B
PMP03-24S15WA/B
PMP03-24S24WA/B
PMP03-24D05WA/B
PMP03-24D12WA/B
PMP03-24D15WA/B
PMP03-48S3P3WA/B
PMP03-48S05WA/B
PMP03-48S12WA/B
PMP03-48S15WA/B
PMP03-48S24WA/B
PMP03-48D05WA/B
PMP03-48D12WA/B
PMP03-48D15WA/B
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±12 VDC
±15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±12 VDC
±15 VDC
1000 mA
600 mA
250 mA
200 mA
125 mA
±300 mA
±125 mA
±100 mA
1000 mA
600 mA
250 mA
200 mA
125 mA
±300 mA
±125 mA
±100 mA
6 mA
6 mA
6 mA
6 mA
6 mA
6 mA
6 mA
6 mA
4 mA
4 mA
4 mA
4 mA
4 mA
4 mA
4 mA
4 mA
82%
84.5%
87%
87%
87%
83%
86.5%
86%
81%
83%
86.5%
87%
86%
83%
86%
86%
1050
mF
750
mF
130
mF
100
mF
39
mF
± 430
mF
± 75
mF
± 56
mF
1050
mF
750
mF
130
mF
100
mF
39
mF
± 430
mF
± 75
mF
± 56
mF
Notes:
1. The PMP03 (W) series can meet EMI Class A with no external filter. And Class B only with
external components. For more detail information, please contact Powerbox.
2. An external input filter capacitor is required if the module has to meet EN61000-4-4,
EN61000-4-5.
The PMP03-05SXXXXXrecommended an aluminum electrolytic capacitor (Nippon Chemi-
con KY series, 1000μF/25V).
And a reverse diode (Vishay V10P45) to connect in parallel.
The PMP03-12&24SXXXXX recommended an aluminum electrolytic capacitor (Nippon
Chemi-con KY series, 470μF/50V).
The PMP03-48SXXXXX recommended an aluminum electrolytic capacitor (Nippon Chemi-
con KY series, 330μF/100V).
CAUTION: This power module is not internally fused. An input line fuse must always be used.
MEDLINE
www.powerbox.info
Medline PMP03 Series
3.3W 2:1 & 4:1 SINGLE OUTPUT MEDICAL DC/DC CONVERTER
Part Number Structure
PMP03 - 48
Series Name
Input
Voltage (VDC)
05:
4.5-9
12:
9-18
24:
18-36
48:
36-75
W:
24:
9-36
48:
18-75
S
Output
Quantity
S:
Single
05
Output
Voltage (VDC)
3P3:
3.3
05:
5
12:
12
15:
15
24:
24
05:
±5
12:
±12
15:
±15
W
Input
Range
£
2:1
W:
4:1
A
-
P
Remote On/Off
Option
£
No On/Off control
P:
Remote On/Off
(Only for B type
Pin connection)
T
Trim
Option
£:
No Trim
T:
Trim
(Only for B type
Pin connection)
Pin Connection
Option
A:
A type (standard)
B:
B type
D:
Dual
Derating Curve
Mechanical
A TYPE PIN CONNECTION (STNDARD)
B TYPE PIN CONNECTION
DIP PIN CONNECTION
PIN
SINGLE
1
+ INPUT
11
NO PIN
12
-OUTPUT
13
+OUTPUT
15
NO PIN
23
- INPUT
24
- INPUT
DUAL
+ INPUT
COMMON
NO PIN
-OUTPUT
+OUTPUT
- INPUT
- INPUT
1. All dimensions in Inch (mm)
Tolerance: X.XX±0.02 (X.X±0.5), X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance ±0.01 (0.25)
3. Pin dimension tolerance ±0.004 (0.1)
DIP PIN CONNECTION
PIN
SINGLE
1
CTRL (Option)
2
- INPUT
10
TRIM (Option)
11
NO PIN / NC (**)
14
+OUTPUT
16
-OUTPUT
22
+INPUT
23
+INPUT
DUAL
CTRL (Option)
- INPUT
TRIM (Option)
-OUTPUT
+OUTPUT
COMMON
+INPUT
+INPUT
** The Pin 11 is ”NO PIN” when single output with Trim option (Suffix: -T).
The Pin 11 is ”NC” when single output without TRIM pin.
1. All dimensions in Inch (mm)
Tolerance: X.XX±0.02 (X.X±0.5), X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance ±0.01 (0.25)
3. Pin dimension tolerance ±0.004 (0.1)
MEDLINE
www.powerbox.info