Radial Aluminum Electrolytic Capacitors
ESS, +105°C
Overview
Applications
Typical applications include portable micro computers, disk
drives, calculators, and audio equipment.
The KEMET ESS radial aluminum electrolytic capacitors
are designed for applications requiring a low profile
miniature solution.
Benefits
•
•
•
•
1,000 hour operating life
Operating temperature of up to 105°C
7 – 9 mm case height
Safety vent on the capacitor base
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
Part Number System
ESS
Series
Radial
Aluminum
Electrolytic
336
Capacitance
Code (pF)
First two digits
represent
significant
figures for
capacitance
values. Last
digit specifies
the number
of zeros to be
added.
M
Tolerance
M = ±20%
004 = 4
6R3 = 6.3
010 = 10
016 = 16
004
Rated Voltage
(VDC)
025 = 25
035 = 35
050 = 50
063 = 63
A
Electrical
Parameters
A = Standard
B2
Size Code
See Dimension
Table
AA
Packaging
See Ordering
Options Table
Built Into Tomorrow
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
A4057_ESS • 11/17/2020
1
Radial Aluminum Electrolytic Capacitors – ESS, +105°C
Ordering Options Table
Diameter
4 – 22
4–5
4–8
4–8
10
4–8
4–8
4–5
10 – 13
16
18
Length
Packaging Type
Lead Type
Lead Length
(mm)
20/15 Minimum
H
0
= 16 ±0.75
H
0
= 18.5 ±0.75
H
0
= 16 ±0.75
H
0
= 18.5 ±0.75
H
0
= 16 ±0.75
H
0
= 18.5 ±0.75
H
0
= 16 ±0.75
H
0
= 18.5 ±0.75
H
0
= 18.5 ±0.75
H
0
= 18.5 ±0.75
Lead and
Packaging Code
AA
LA
KA
JA
KA
DA
EA
FA
EA
EA
EA
Standard Bulk Packaging Options
All
All
All
All
≤ 20
All
All
All
All
All
≤ 25
Bulk (bag)
Tape & Reel
Tape & Reel
Tape & Reel
Tape & Reel
Ammo
Ammo
Ammo
Ammo
Ammo
Ammo
Straight
Tape & Reel
Formed to 2.5 mm
2.5 mm lead spacing
Formed to 5 mm
Straight
Ammo Pack
Formed to 5 mm
Straight
Formed to 2.5 mm
5 mm lead spacing
7.5 mm lead spacing
7.5 mm lead spacing
Contact KEMET for other lead and packaging options
Environmental Compliance
As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental
effects of both our capacitors and their production. In Europe (RoHS Directive) and in some other geographical areas like
China, legislation has been put in place to prevent the use of some hazardous materials, such as lead (Pb), in electronic
equipment. All products in this catalog are produced to help our customers’ obligations to guarantee their products and fulfill
these legislative requirements. The only material of concern in our products has been lead (Pb), which has been removed
from all designs to fulfill the requirement of containing less than 0.1% of lead in any homogeneous material. KEMET will
closely follow any changes in legislation world wide and make any necessary changes in its products, whenever needed.
Some customer segments such as medical, military and automotive electronics may still require the use of lead in electrode
coatings. To clarify the situation and distinguish products from each other, a special symbol is used on the packaging labels
for RoHS compatible capacitors.
Due to customer requirements, there may appear additional markings such as lead free (LF) or lead-free wires (LFW) on the
label.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
A4057_ESS • 11/17/2020
2
Radial Aluminum Electrolytic Capacitors – ESS, +105°C
Dimensions – Millimeters
SIDE VIEW
L
LL+
D
LL−
d
TERMINAL END VIEW
P
Size Code
B2
C2
E2
G1
G2
D
Nominal
4.0
5.0
6.3
8.0
8.0
Tolerance
±0.5
±0.5
±0.5
±0.5
±0.5
Nominal
7
7
7
7
9
L
Tolerance
+1.5/−0
+1.5/−0
+1.5/−0
+1.5/−0
+1.5/−0
Nominal
1.5
2.0
2.5
3.5
3.5
P
Tolerance
±0.5
±0.5
±0.5
±0.5
±0.5
Nominal
0.45
0.45
0.45
0.50
0.50
d
Tolerance
Nominal
Nominal
Nominal
Nominal
Nominal
LL+/LL−
Mininimum
20/15
20/15
20/15
20/15
20/15
Performance Characteristics
Item
Capacitance Range
Capacitance Tolerance
Rated Voltage
Life Test
Operating Temperature
Leakage Current
Performance Characteristics
1 – 470 µF
±20% at 120 Hz/20°C
4 – 63 VDC
1,000 hours (see conditions in Test Method & Performance)
−40°C to +105°C
I ≤ 0.01 CV or 3 µA, whichever is greater
C = rated capacitance (µF), V = rated voltage (VDC). Voltage applied for 2 minutes at 20°C.
Impedance Z Characteristics at 120 Hz
Rated Voltage (VDC)
Z (−25°C)/Z (20°C)
Z (−40°C)/Z (20°C)
4
6
12
6
4
8
10
3
6
16
2
4
25
2
4
35
2
3
50
2
3
63
2
3
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
A4057_ESS • 11/17/2020
3
Radial Aluminum Electrolytic Capacitors – ESS, +105°C
Compensation Factor of Ripple Current (RC) vs. Frequency
Capacitance Range (µF)
1 – 47
100 – 330
120 Hz
1.00
1.00
300 Hz
1.20
1.10
1 kHz
1.30
1.15
10 kHz
1.50
1.20
Test Method & Performance
Conditions
Temperature
Test Duration
Ripple Current
Voltage
Load Life Test
105°C
1,000 hours
Maximum ripple current specified at 120 Hz 105°C
The sum of DC voltage and the peak AC voltage
must not exceed the rated voltage of the capacitor
Shelf Life Test
105°C
1,000 hours
No ripple current applied
No voltage applied
Performance
Capacitance Change
Dissipation Factor
Leakage Current
The following specifications will be satisfied when the capacitor is restored to 20°C:
Within ±20% of the initial value
Does not exceed 200% of the specified value
Does not exceed specified value
Shelf Life
The capacitance, ESR and impedance of a capacitor will not change significantly after extended storage periods, however,
the leakage current will very slowly increase.
KEMET's E aluminum electrolytic capacitors should not be stored in high temperatures or where there is a high level of
humidity. The suitable storage condition for KEMET's E aluminum electrolytic capacitors is +5 to +35°C and less than 75%
in relative humidity. KEMET's E aluminum electrolytic capacitors should not be stored in damp conditions such as water,
saltwater spray or oil spray. KEMET's E aluminum electrolytic capacitors should not be stored in an environment full of
hazardous gas (hydrogen sulphide, sulphurous acid gas, nitrous acid, chlorine gas, ammonium, etc.) KEMET's E aluminum
electrolytic capacitors should not be stored under exposure to ozone, ultraviolet rays or radiation.
If a capacitor has been stored for more than 18 months under these conditions and it shows increased leakage current,
then a treatment by voltage application is recommended.
Re-Age (Reforming) Procedure
Apply the rated voltage to the capacitor at room temperature for a period of one hour, or until the leakage current has fallen
to a steady value below the specified limit. During re-aging a maximum charging current of twice the specified leakage
current or 5 mA, whichever is greater, is suggested.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
A4057_ESS • 11/17/2020
4
Radial Aluminum Electrolytic Capacitors – ESS, +105°C
Table 1 – Ratings & Part Number Reference
VDC
4
4
4
4
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
10
10
10
10
10
10
10
10
10
10
10
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
25
25
25
25
25
25
25
25
25
25
25
25
25
35
35
35
35
Rated
VDC Surge
Case Size
Capacitance
Voltage
D x L (mm)
120 Hz 20°C (µF)
5
5
5
5
8
8
8
8
8
8
8
8
13
13
13
13
13
13
13
13
13
13
13
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
30
30
30
30
30
30
30
30
30
30
30
30
30
44
44
44
44
33
47
100
220
22
33
47
47
100
100
220
330
22
22
33
33
47
47
47
100
100
220
470
2.2
3.3
4.7
10
22
22
33
33
47
47
68
100
100
150
220
220
330
470
4.7
10
10
10
22
22
22
33
33
47
47
100
100
4.7
4.7
10
10
4x7
4x7
5x7
6.3 x 7
4x7
5x7
4x7
5x7
5x7
6.3 x 7
6.3 x 7
8x7
4x7
5x7
4x7
5x7
4x7
5x7
6.3 x 7
5x7
6.3 x 7
6.3 x 7
8x9
4x7
4x7
4x7
4x7
4x7
5x7
4x7
5x7
5x7
6.3 x 7
5x7
5x7
6.3 x 7
6.3 x 7
8x7
8x9
8x9
8x9
4x7
4x7
5x7
6.3 x 7
4x7
5x7
6.3 x 7
5x7
6.3 x 7
5x7
6.3 x 7
6.3 x 7
8x7
4x7
5x7
4x7
5x7
DF
120 Hz
20°C
(tan δ %)
35
35
35
35
24
24
24
24
24
24
24
24
20
20
20
20
20
20
20
20
20
20
20
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
15
15
15
15
15
15
15
15
15
15
15
15
15
12
12
12
12
RC
120 Hz
105°C
(mA)
30
35
55
95
37
42
46
55
75
90
130
140
31
38
39
47
50
60
60
85
100
135
165
7
13
19
29
36
44
50
57
75
77
84
94
110
120
140
140
155
165
24
33
35
35
43
51
53
55
65
67
79
120
120
24
24
34
36
LC
20°C
2 minutes
(µA)
3.0
3.0
4.0
8.8
3.0
3.0
3.0
3.0
6.3
6.3
13.9
20.8
3.0
3.0
3.3
3.3
4.7
4.7
4.7
10.0
10.0
22.0
47.0
3.0
3.0
3.0
3.0
3.5
3.5
5.3
5.3
7.5
7.5
10.9
16.0
16.0
24.0
35.2
35.2
52.8
75.2
3.0
3.0
3.0
3.0
5.5
5.5
5.5
8.3
8.3
11.8
11.8
25.0
25.0
3.0
3.0
3.5
3.5
Part Number
ESS336M004AB2(1)
ESS476M004AB2(1)
ESS107M004AC2(1)
ESS227M004AE2(1)
ESS226M6R3AB2(1)
ESS336M6R3AC2(1)
ESS476M6R3AB2(1)
ESS476M6R3AC2(1)
ESS107M6R3AC2(1)
ESS107M6R3AE2(1)
ESS227M6R3AE2(1)
ESS337M6R3AG1(1)
ESS226M010AB2(1)
ESS226M010AC2(1)
ESS336M010AB2(1)
ESS336M010AC2(1)
ESS476M010AB2(1)
ESS476M010AC2(1)
ESS476M010AE2(1)
ESS107M010AC2(1)
ESS107M010AE2(1)
ESS227M010AE2(1)
ESS477M010AG2(1)
ESS225M016AB2(1)
ESS335M016AB2(1)
ESS475M016AB2(1)
ESS106M016AB2(1)
ESS226M016AB2(1)
ESS226M016AC2(1)
ESS336M016AB2(1)
ESS336M016AC2(1)
ESS476M016AC2(1)
ESS476M016AE2(1)
ESS686M016AC2(1)
ESS107M016AC2(1)
ESS107M016AE2(1)
ESS157M016AE2(1)
ESS227M016AG1(1)
ESS227M016AG2(1)
ESS337M016AG2(1)
ESS477M016AG2(1)
ESS475M025AB2(1)
ESS106M025AB2(1)
ESS106M025AC2(1)
ESS106M025AE2(1)
ESS226M025AB2(1)
ESS226M025AC2(1)
ESS226M025AE2(1)
ESS336M025AC2(1)
ESS336M025AE2(1)
ESS476M025AC2(1)
ESS476M025AE2(1)
ESS107M025AE2(1)
ESS107M025AG1(1)
ESS475M035AB2(1)
ESS475M035AC2(1)
ESS106M035AB2(1)
ESS106M035AC2(1)
VDC
VDC Surge
Rated Capacitance
Case Size
DF
RC
LC
Part Number
(1) Insert packaging code. See Ordering Options Table for available options.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
A4057_ESS • 11/17/2020
5