Product data sheet
Characteristics
SR3NET01BD
Ethernet communication interface - for SR3
24V DC smart relay
Product availability: Stock - Normally stocked in distribution facility
Main
Commercial Status
Range of product
Product or component
type
Commercialised
Zelio Logic
Ethernet communication module
Complementary
Product compatibility
Communication port protocol
Communication port support
Electrical connection
Programming language
Connections - terminals
All modules with 24 V supply SR3 B...BD
Ethernet
10/100BASE-T
1 connector RJ45
FBD
Screw terminals, 2 x 0.25...2 x 0.75 mm², 24...18, flexible cable with cable end
Screw terminals, 1 x 0.25...1 x 2.5 mm², 24...14, flexible cable with cable end
Screw terminals, 2 x 0.25...2 x 1.5 mm², 23...16, solid cable
Screw terminals, 1 x 0.25...1 x 2.5 mm², 24...14, solid cable
Screw terminals, 1 x 0.25...1 x 2.5 mm², 24...14, semi-solid cable
4.42 lbf.in (0.5 N.m)
1 LED for status (STS)
1 LED for communication (LK/ACT 10/100)
0.24 lb(US) (0.11 kg)
Tightening torque
Local signalling
Product weight
Environment
Product certifications
CSA
C-Tick
GOST
UL
EN/IEC 60068-2-27 Ea
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-5
IP40 (front panel) conforming to IEC 60529
IP20 (terminal block) conforming to IEC 60529
Low voltage directive conforming to EN/IEC 61131-2
EMC directive conforming to EN/IEC 61131-2 zone B
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-2
Class B conforming to EN 55022-11 group 1
2 conforming to EN/IEC 61131-2
-4...131 °F (-20...55 °C) conforming to IEC 60068-2-1 and IEC 60068-2-2
-4...104 °F (-20...40 °C) conforming to IEC 60068-2-1 and IEC 60068-2-2
-40...158 °F (-40...70 °C)
6561.68 ft (2000 m)
<= 10000 ft (3048 m)
95 % without condensation or dripping water
1
Standards
IP degree of protection
Environmental characteristic
Disturbance radiated/conducted
Pollution degree
Ambient air temperature for operation
Ambient air temperature for storage
Operating altitude
Altitude transport
Relative humidity
Feb 6, 2014
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.