Relay and Socket Usage Chart
Relay
CB
(8-pin octal)
CB
(11-pin octal)
CD
(8-pin octal)
CD
(11-pin octal)
CG
(8-pin octal)
CG
(11-pin octal)
CH
(8-pin octal)
CH
(11-pin octal)
CK
(8-pin octal)
CK
(11-pin octal)
CL-41 & CL-44
Socket
27E122
27E891
27E123
27E892
27E122
27E891
27E123
27E892
27E122
27E891
27E123
27E892
27E122
27E891
27E123
27E892
27E122
27E891
27E123
27E892
27E043
27E046
27E067
27E121
27E396
27E893
Terminal
Type
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
PC
QC & Solder
Screw
QC & Solder
Screw
Solder
PC
QC & Solder
Screw
QC & Solder
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Hold-Down
Spring
—
—
Notes
—
5
—
5
—
5
—
5
—
5
—
5
—
5
—
5
—
5
—
5
—
—
—
—
—
5
—
—
—
—
—
5
—
5
—
5
—
5
—
5
—
5
—
5
—
5
Socket
Page
109
109
109
109
109
109
109
109
109
109
109
109
109
109
109
109
109
109
109
109
101
101
101
102
101
102
101
101
101
102
101
102
109
109
109
109
109
109
109
109
109
109
109
109
109
109
Comments
—
—
—
—
—
—
—
—
20C228 or 20C254
20C228 or 20C254
20C228 or 20C254
20C314
20C254
20C318
20C247
20C247
20C247
20C314
20C318
—
—
—
—
—
—
—
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
Use 2 pieces 20C314 per socket.
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
20C247 held in place by socket hold down screw.
20C247 held in place by socket hold down screw.
20C247 held in place by socket hold down screw.
Use 2 pieces 20C314 per socket.
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
CL-51
27E043
27E046
27E067
27E121
27E396
27E893
27E122
27E891
27E123
27E892
27E122
27E891
27E123
27E892
27E123
27E892
27E122
27E891
27E122
27E891
CN1
(8-pin octal)
CNM5
(11-pin octal)
CNS
(8-pin octal)
CNS
(11-pin octal)
CNT
(11-pin octal)
CR
(8-pin octal)
CS
(8-pin octal)
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Flange mount sockets pre-assembled on steel mounting plates. Grounding is not recommended for currents of 5 amps AC & above.
Listed hold-down springs cannot be used for R10S.
On R10L series hold down spring fits to the side of light emitting diode.
Use 40G432 insulator or suitable insulator (2 per socket).
Snap-mount relay sockets snap onto 24A110 mounting rail without extra hardware.
27E893 cannot be used with KUIP and KUGP series relays.
Relay and Socket Usage Chart continued on next page.
Relay and Socket Usage Chart
Relay
CU-41 & CU-44
Socket
27E043
27E046
27E067
27E396
27E400
27E121
27E893
Terminal
Type
Solder
PC
QC & Solder
QC & Solder
Solder
Screw
Screw
Solder
PC
QC & Solder
Screw
QC & Solder
Screw
—
—
Screw
Solder
PC
Screw
Screw
Screw
Solder
PC
PC
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Solder
PC
QC & Solder
Screw
QC & Solder
Solder
Screw
Solder
PC
QC & Solder
Screw
QC & Solder
Screw
Hold-Down
Spring
20C228 or 20C254
20C228 or 20C254
20C228 or 20C254
20C254
20C254
20C314
20C318
20C247
20C247
20C247
20C314
20C318
—
—
20C297
20C217
20C217
20C297
—
20C217
20C217
20C217
20C297
20C297
—
20C318
—
20C318
—
20C318
—
20C318
—
20C318
20C228 or 20C254
20C228 or 20C254
20C228 or 20C254
20C314
20C254
20C254
20C318
20C247
20C247
20C247
20C314
20C318
Notes
—
—
—
—
—
—
5
—
—
—
—
—
5
—
—
—
—
—
5
—
5
—
—
—
—
5
—
5
—
5
—
5
—
5
—
5
—
—
—
—
—
—
5, 6
—
—
—
—
—
5
Socket
Page
101
101
101
101
101
102
102
101
101
101
102
101
102
—
—
94
94
94
94
109
109
91
91
91
91
91
109
109
109
109
109
109
109
109
109
109
101
101
101
102
101
101
102
101
101
101
102
101
102
Comments
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
Use 2 pieces 20C314 per socket.
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
20C247 held in place by socket hold down screw.
20C247 held in place by socket hold down screw.
20C247 held in place by socket hold down screw.
Use 2 pieces 20C314 per socket.
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
Refer to page 176 for I/O modules mounting board details.
Refer to page 184 for Slim Line I/O modules mounting board details.
CU-51
27E043
27E046
27E067
27E121
27E396
27E893
—
—
27E487
27E488
27E489
27E895
27E123
27E892
27E006
27E007
27E023
27E166
27E894
27E122
27E891
27E123
27E892
27E122
27E891
27E122
27E891
27E123
27E892
27E043
27E046
27E067
27E121
27E396
27E400
27E893
IAC & IDC
IACM & IDCM
K10
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
KBP
(11-pin octal)
KH & KHA
(type-P,S,U,X)
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
Use 2 pieces 20C314 per socket.
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
20C247 held in place by socket hold down screw.
20C247 held in place by socket hold down screw.
20C247 held in place by socket hold down screw.
Use 2 pieces 20C314 per socket.
Use 20C317 anchor clip hold down spring (2 supplied per socket).
KR Sealed
(8-pin octal)
KR Sealed
(11-pin octal)
KRP3-H
(8-pin octal)
KRP & KRPA
(8-pin octal)
KRP & KRPA
(11-pin octal)
KUEP,
KUGP, KUIP,
KUMP & KUP
[1-3 poles
with .187"
(4.75mm) QC]
KUL
with .187"
(4.75mm) QC]
27E043
27E046
27E067
27E121
27E396
27E893
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Flange mount sockets pre-assembled on steel mounting plates. Grounding is not recommended for currents of 5 amps AC & above.
Listed hold-down springs cannot be used for R10S.
On R10L series hold down spring fits to the side of light emitting diode.
Use 40G432 insulator or suitable insulator (2 per socket).
Snap-mount relay sockets snap onto 24A110 mounting rail without extra hardware.
27E893 cannot be used with KUIP and KUGP series relays.
Relay and Socket Usage Chart continued on next page.
Relay and Socket Usage Chart
Relay
KUP
[4 pole
with .110"
(2.79mm) QC]
OAC & ODC
OACM & ODCM
R10, R10L &
R10S (2 pole)
Socket
27E415
27E419
27E867
—
—
27E125
27E162
27E128
27E446
27E709
27E193
27E212
27E342
27E317
27E460
27E126
27E163
27E129
27E194
27E213
27E714
27E629
27E461
27E127
27E130
27E195
27E630
27E462
27E122
27E891
27E123
27E892
27E936
27E937
27E1038
27E1039
27E122
27E891
27E043
27E046
27E067
27E088
27E121
27E396
27E400
27E893
Terminal
Type
QC & Solder
PC
Screw
—
—
Solder
Solder
PC Stag.
Solder
PC Stag.
PC Stag.
PC Stag.
PC In-Line
Solder/Bkt. Mt.
Screw
Solder
Solder
PC Stag.
PC Stag.
PC Stag.
PC Stag.
PC In-Line
Screw
Solder
PC Stag.
PC Stag.
PC In-Line
Screw
Screw
Screw
Screw
Screw
PC
PC
Screw
Screw
Screw
Screw
Solder
PC
QC & Solder
Blank
Screw
QC & Solder
Solder
Screw
Hold-Down
Spring
20C228 or 20C254
20C228 or 20C254
20C254
—
—
20C249
20C249
20C249 or 20C259
20C249
20C249 or 20C259
20C249 or 20C259
20C249 or 20C259
20C249 or 20C259
20C249
20C249 or 20C259
20C250
20C250
20C250
20C250 or 20C259
20C250 or 20C259
20C250 or 20C259
20C250 or 20C259
20C250 or 20C259
20C251
20C251 or 20C259
20C251 or 20C259
20C251 or 20C259
20C251 or 20C259
—
20C318
—
20C318
20C330
20C330
20C330
20C330
—
Notes
—
—
4
—
—
2, 3
2, 3
2, 3
1, 2, 3
2, 3
2, 3
2, 3
2, 3
2, 3
2, 3, 4
2, 3
2, 3
2, 3
2, 3
2, 3
2, 3
2, 3
2, 3, 4
3
3
3
3
3, 4
—
5
—
5
—
—
5
5
—
5
—
—
—
—
—
—
—
5
Socket
Page
101
101
101
—
—
86
86
86
86
86
86
86
86
87
87
86
86
86
86
86
86
86
87
86
86
86
86
87
109
109
109
109
72
72
72
72
109
109
101
101
101
101
101
101
101
101
Comments
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
20C228 held in place by socket hold down screw whereas 20C254
snaps onto socket.
Refer to page 176 for I/O module mounting board details.
Refer to page 184 for Slim Line I/O modules mounting board details.
Tin plated terminals with grounding strip.
Tin plated terminals no grounding provision.
Tin plated terminals with grounding strip.
Tin plated terminals with grounding strip.
Gold flashed terminals with grounding strip.
Tin plated terminals with grounding terminals.
Tin plated terminals no grounding provision.
Tin plated terminals no grounding provision.
Tin plated terminals with grounding strip.
Tin plated terminals no grounding provision.
Tin plated terminals with grounding strip.
Tin plated terminals no grounding provision.
Tin plated terminals with grounding strip.
Tin plated terminals with grounding terminal.
Tin plated terminals no grounding provision.
Gold flashed terminals no grounding provision.
Tin plated terminals no grounding provision.
Tin plated terminals no grounding provision.
Tin plated terminals with grounding strip.
Tin plated terminals with grounding strip.
Tin plated terminals with grounding terminal.
Tin plated terminals no ground provision.
Tin plated terminals no grounding provision.
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
Use 20C317 anchor clip for hold down spring (2 supplied per socket).
Use with Code 1.
Use with Codes 2, 3 & 5.
Use with Code 1.
Use with Codes 2, 3 & 5.
R10, R10L &
R10S (4 pole)
R10 & R10L
(6 pole)
R10-T1
(8-pin octal)
R10-T2
(11-pin octal)
RKA/RKS
S89R11APP &
S89R11DPP
(8-pin octal)
SDAS-01
—
—
—
—
20C314
—
—
—
Use 2 pieces 20C314 per socket.
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Flange mount sockets pre-assembled on steel mounting plates. Grounding is not recommended for currents of 5 amps AC & above.
Listed hold-down springs cannot be used for R10S.
On R10L series hold down spring fits to the side of light emitting diode.
Use 40G432 insulator or suitable insulator (2 per socket).
Snap-mount relay sockets snap onto 24A110 mounting rail without extra hardware.
27E893 cannot be used with KUIP and KUGP series relays.
Tyco Electronics Corporation - P&B, Winston-Salem, NC 27102
Technical Support Center: 1-800-522-6752, www.pandbrelays.com
Specifications and availability subject to change without notice.
13CXXXX
Printed in U.S.A.
IH/3-00