760232603 | P-024-CN-RB-F12AQ/5Y/99E
Indoor Plenum All-Dielectric Central Tube Ribbon Cable
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber indoor cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
Cable Qualification Standards
ANSI/ICEA S-83-596 | Telcordia GR-409
Representative Image
General Specifications
Cable Type
Construction Type
Subunit Type
Ribbon central tube
Non-armored
Gel-free
Construction Materials
Fiber Type Solution
Total Fiber Count
Fiber Type
OM3, bend insensitive
24
OM3, bend insensitive
page 1 of 3
March 30, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
760232603 | P-024-CN-RB-F12AQ/5Y/99E
Fiber Type, quantity
Fibers per Ribbon, quantity
Jacket Color
24
12
Aqua
Dimensions
Buffer Tube/Subunit Diameter
Cable Weight
Diameter Over Jacket
6.00 mm | 0.24 in
57.0 lb/kft | 85.0 kg/km
9.20 mm | 0.36 in
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
182.9 mm | 7.2 in
91.4 mm | 3.6 in
Tensile Load, long term, maximum
75 lbf | 334 N
Tensile Load, short term, maximum
300 lbf | 1335 N
Flame Test Specifications
Flame Test Listing
Flame Test Method
NEC OFNP (UL) and c(UL)
NFPA 262
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Plenum
0 °C to +70 °C (+32 °F to +158 °F)
-20 °C to +70 °C (-4 °F to +158 °F)
-40 °C to +70 °C (-40 °F to +158 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
Impact Test Method
Strain
Strain Test Method
Twist
Twist Test Method
10 N/mm | 57 lb/in
FOTP-41 | IEC 60794-1 E3
25 cycles
FOTP-104 | IEC 60794-1 E6
2.17 ft lb | 2.94 N-m
FOTP-25 | IEC 60794-1 E4
See long and short term tensile loads
FOTP-33 | IEC 60794-1 E1
10 cycles
FOTP-85 | IEC 60794-1 E7
page 2 of 3
March 30, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
760232603 | P-024-CN-RB-F12AQ/5Y/99E
Environmental Test Specifications
Heat Age
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-20 °C to +85 °C (-4 °F to +185 °F)
IEC 60794-1 F9
0 °C to +70 °C (+32 °F to +158 °F)
FOTP-37 | IEC 60794-1 E11
-20 °C to +70 °C (-4 °F to +158 °F)
FOTP-3 | IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
Included Products
CS -5Y-RB (Product Component—not orderable)
—
50µm OM3 Bend-Insensitive Multimode Fiber
CS-5Y-
Component—
50µ
Bend-
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 30, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018