Absolute Maximum Ratings (Ambient Temperature 25°C):
Properties
Power Dissipation
Test conditions
P
Diss
duty/ 10 @ 1 kHz
I
F Peak
I
F
V
REV
V
ESD HBM
Value
140
700
70
5
2000
Unit
mW
mA
mA
V
V
Polarity Mark
(Anode)
2
0,45
typ.
0,87
typ.
1
0,45
typ.
0,8 0,65
0,9
0,65 0,8
2
1
1,4
Peak Forward Current
Continuous Forward Current
Reverse Voltage
ESD Threshold/ Human Body
Model
0,6
Optical Properties:
Chip Technology
AlGaAs
Infrared
Waterclear
Emitting Color
Lens Type
1,04 typ.
2,0 ±0,1
Scale - 10:1
Schematic:
3,0 ±0,1
General Information:
Operating Temperature
-40 °C up to +85 °C
-40 °C up to +85 °C; 60% RH max.
MSL
3
2
1
1,0 ±0,1
-
1
+
2
Storage Temperature (in original
packaging)
Moisture Sensitive Level
Scale - 10:1
LEDs emit high intensity IR light.
not look directly into the LED during operation.
This
can be harmful to your eyes.
Wear protective eyewear.
lease follow safety precautions given in
P
IEC 60825-1 and IEC 62471.
Keep out of reach of children.
Avoid direct eye and skin exposure to LED!
Do
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
CAUTION – IR
IR
CHECKED
GENERAL TOLERANCE
PROJECTION
METHOD
KaS
DESCRIPTION
ZAn
DIN ISO 2768-1m
WL-SISW SMD Infrared Sideview
LED Waterclear
SIZE
REVISION
STATUS
ORDER CODE
15411485AA370
DATE (YYYY-MM-DD)
BUSINESS UNIT
PAGE
1104
001.001
Valid
2018-04-11
eiPal
1/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Electrical & Optical Properties:
Properties
Peak Wavelength
Centroid Wavelength
Radiant Intensity
Forward Voltage
Spectral Bandwidth
Reverse Current
Viewing Angle Phi 0°
Test conditions
20 mA
20 mA
20 mA
20 mA
20 mA
5V
20 mA
λ
Peak
λ
Centroid
I
e
V
F
Δλ
I
REV
2θ
50%
1
Value
min.
typ.
850
845
2
1.4
30
10
130
10
2
max.
Unit
nm
nm
mW/sr
V
nm
µA
°
Viewing Angle:
-65°
100
90
0°
10°
20°
30°
40°
45°
Relative Luminous Intensity (%)
80
70
50°
60
50
40
70°
30
20
10
80°
60°
65°
90°
-90
-45
0
10
20
30
40
50
60
70
80
90
100
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
CHECKED
GENERAL TOLERANCE
PROJECTION
METHOD
KaS
DESCRIPTION
ZAn
DIN ISO 2768-1m
WL-SISW SMD Infrared Sideview
LED Waterclear
SIZE
REVISION
STATUS
ORDER CODE
15411485AA370
DATE (YYYY-MM-DD)
BUSINESS UNIT
PAGE
1104
001.001
Valid
2018-04-11
eiPal
2/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Spectral:
Forward Current vs. Forward Voltage:
250
200
100
80
Forward Current [mA]
400
500
600
700
800
900
1000
1100
150
Relative Intensity [%]
60
40
100
20
0
50
Wavelength [nm]
0
0.0
0.5
1.0
1.5
2.0
Forward Voltage [V]
2.5
3.0
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
CHECKED
GENERAL TOLERANCE
PROJECTION
METHOD
KaS
DESCRIPTION
ZAn
DIN ISO 2768-1m
WL-SISW SMD Infrared Sideview
LED Waterclear
SIZE
REVISION
STATUS
ORDER CODE
15411485AA370
DATE (YYYY-MM-DD)
BUSINESS UNIT
PAGE
1104
001.001
Valid
2018-04-11
eiPal
3/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Relative Radiant Intensity vs. Forward Current:
16.00
Derating Curve:
90
14.00
80
70
12.00
Relative Radiant Intensity
10.00
Forward Currennt (mA)
60
50
8.00
40
6.00
30
4.00
20
2.00
10
0.00
0
50
100
150
Forward Current [mA]
200
250
0
0
10
20
30
40
50
60
70
Ambient Temperature (℃)
80
90
100
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
CHECKED
GENERAL TOLERANCE
PROJECTION
METHOD
KaS
DESCRIPTION
ZAn
DIN ISO 2768-1m
WL-SISW SMD Infrared Sideview
LED Waterclear
SIZE
REVISION
STATUS
ORDER CODE
15411485AA370
DATE (YYYY-MM-DD)
BUSINESS UNIT
PAGE
1104
001.001
Valid
2018-04-11
eiPal
4/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Packaging Specification - Tape and Reel: [mm]
P0
K0
T
E1
B
W1
close to center
D
W3
A
D0
P2
F
W
C
B0
E2
Top Cover
Tape
W2
A
End
D1
A0
P1
T2
Feeding direction
T1
Start
Carrier Tape
Cover Tape
detail A
A
Cover Tape
Chip Cavity
Sprocket Hole
No Component
min.160mm
Anode Mark
Components
No Component
min.100mm
Cover Tape
min. 400mm
Tolerance
Tape width
8 mm
Embossment
packaging is reffered to the international standard IEC 60286-3:2013
tolerance
value
A0
typ.
B0
typ.
W
+0,3/ -0,1
8,0
T
ref.
T1
T2
K0
max. typ. typ.
0,1
1,37
P0
±0,1
4,0
P1
±0,1
4,0
P2
±0,05
2,0
D0
+0,1/ -0,0
1,5
D1
min.
0,3
E1
±0,1
1,75
E2
F
min. ±0,05
6,25 3,5
Tape Type 2a
Polystyrene
VPE / packaging unit
pcs.
A
± 2,0
178
B
min.
1.5
C
min.
12.8
D
min.
20.2
N
N
min.
50
A
W1
+1,5
8.4
W2
max.
14.4
W3
min.
7.9
W3
max.
10.9
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
CREATED
CHECKED
GENERAL TOLERANCE
PROJECTION
METHOD
KaS
DESCRIPTION
ZAn
DIN ISO 2768-1m
165° - 180°
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
WL-SISW SMD Infrared Sideview
LED Waterclear
SIZE
REVISION
STATUS
ORDER CODE
15411485AA370
DATE (YYYY-MM-DD)
BUSINESS UNIT
PAGE
Pull-of force
Tape width
8 mm
0,1 N - 1,0 N
1104
001.001
Valid
2018-04-11
eiPal
5/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.