Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1505F Coax - RG-59/U Type
For more Information
please call
1-800-Belden1
Description:
22 AWG stranded (7x29) .031" bare compacted copper conductor, gas-injected foam HDPE insulation,
tinned copper double braid shield (98% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material
1
22
7x29
Dia. (mm)
BCC - Bare Compacted Copper 0.7874
Insulation
Insulation Material:
Insulation Material
Dia. (mm)
Gas-injected FHDPE - Foam High Density Polyethylene 3.683
Outer Shield
Outer Shield Material:
Layer # Type Outer Shield Material Coverage (%) Dia. (mm) Description
1
2
Braid TC - Tinned Copper
Braid TC - Tinned Copper
94
94
4.2418
4.8006
Layer 1
Layer 2
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter:
6.147 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-35°C To +75°C
75°C
61.016 Kg/Km
400.338 N
60.960 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
CM
CM
Yes
Yes
Yes
01/01/2005
Yes
Page 1 of 4
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1505F Coax - RG-59/U Type
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
RG Type:
Yes
Yes
Yes
59/U
Flame Test
UL Flame Test:
UL1685 UL Loading
Suitability
Suitability - Indoor:
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/m)
0.308414
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
55.777
Nominal Velocity of Propagation:
VP (%)
80
Nominal Delay:
Delay (ns/m)
4.2653
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
40.0282
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
7.8744
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1.000
3.600
5.000
6.000
7.000
10.000
12.000
25.000
67.500
71.500
88.500
100.000
135.000
143.000
180.000
270.000
360.000
540.000
720.000
0.656
1.641
1.969
2.198
2.395
2.953
3.215
4.725
7.874
8.203
9.187
9.843
11.484
11.812
13.452
16.733
19.686
24.279
28.545
Page 2 of 4
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1505F Coax - RG-59/U Type
1000.000
750.000
1500.000
2000.000
2250.000
3000.000
34.451
29.201
43.637
51.512
55.449
66.604
Max. Operating Voltage - UL:
Voltage
300 V RMS
Other Electrical Characteristic 1:
Other Electrical Characteristic 2:
Minimum Return Loss:
Start Freq. (MHz) Stop Freq. (MHz) Min. RL (dB)
5.000
851.000
850.000
4500.000
20.000
15.000
Impedance tested in accordance with ASTM D-4566 paragraph 43.2, option 2
using a 75 Ohm fixed bridge and termination.
Return Loss tested in accordance with ASTM D-4566 paragraph 45.3, using a
75 Ohm fixed bridge and termination.
Sweep Test
Sweep Testing:
100% Sweep tested 5 MHz to 4.5 GHz.
Notes (Overall)
Notes:
Compacted conductor combines impedance uniformity of solid conductors and "nick-resistance" of stranded conductor.
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
1505F B591000
1505F G7V1000
1505F G7W1000
1505F G7X1000
1505F G7Y1000
1505F G8L1000
1505F Z4B1000
1505F 0041000
Notes:
C = CRATE REEL PUT-UP.
Putup
305 MT
305 MT
305 MT
305 MT
305 MT
305 MT
305 MT
305 MT
Ship Weight
20.412 KG
20.412 KG
20.412 KG
20.412 KG
20.412 KG
20.412 KG
20.412 KG
20.412 KG
Color
BLACK, MATTE
RED, MATTE
GREEN, MATTE
BLUE, MATTE
WHITE, MATTE
ORANGE, MATTE
VIO Z4B
YELLOW
C
Notes
C
C
C
C
C
C
Item Desc
#21 GIFHDLDPE DBLB PVC
#21 GIFHDLDPE DBLB PVC
#21 GIFHDLDPE DBLB PVC
#21 GIFHDLDPE DBLB PVC
#21 GIFHDLDPE DBLB PVC
#21 GIFHDLDPE DBLB PVC
#21 GIFHDLDPE DBLB PVC
#21 GIFHDLDPE DBLB PVC
Revision Number: 9
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 09-30-2009
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 4
02-24-2012