Switched and Fused Filtered
Power Entry Modules
Dual Fuse for European Applications
Switched and Fused Filtered
Power Entry Modules
68-BSF Series
Features
Dual fuse for European applications
s
Fuse holder and double pole power ON/OFF switch
provides a convenient/compact package
s
Suitable for products that must conform
to FCC and FTZ requirements
s
Meets over voltage category II of IEC 664
and complies with IEC 950
s
Metal case provides effective EMI shielding
s
IEC connector meets the safety standards of most
certifying agencies
s
Easy access fuse drawer
s
Flange-mounted
s
UL, CSA, and SEMKO approved
s
Designed to be in accordance with VDE 0565, part 3
s
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 51)
s
Circuit Diagram
FUSE
L
L
1
C
X1
E
R
1
L
2
N
SW
C
Y2
N
C
X2
E
C
Y1
L
Applications
Computers and peripheral equipment
s
Electronic equipment
s
Digital equipment
s
Measuring and testing instruments
s
Telecommunications equipment
s
Specifications
Model
68-BSF-020-3-01
68-BSF-020-3-04
68-BSF-040-3-01
68-BSF-040-3-04
68-BSF-060-3-01
68-BSF-060-3-04
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in terminals)
6A
250VAC
4A
0.35mA
2200pF
2200pF
Rated Voltage
(@ 50/60Hz)
Rated
Current
2A
Leakage Current
(Max.)
C
Y1
Capacitance
C
Y2
C
X1
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
C
X2
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
1.6mH
4.2mH
45°C
Inductance
(L
1
)
10.5mH
Temperature
Rise (Max.)
50
SPECTRUM CONTROL INC.
• 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Switched and Fused Filtered
Power Entry Modules
Dual Fuse for European Applications
68-BSF Series
Temperature Characteristics
120
100
80
60
1.573
(40±0.2)
2.273
(57.8)
2 - .142
(3.6)
Hole
R .059
(1.5)
Panel cutout
dimension
mount from
back side
2.399
(61)
2.556
(65)
1.947
(49.5)
1.101
(28)
.248
(6.3)
1.526
(38.8)
Current (%)
2.348
(59.7)
Ø.142
(3.6)
2.340
(59.5)
40
20
0
1.133
(28.8)
Fast-on Tab #250
t= .031
(0.8)
1.573
1.16
+.02
-0
(40.±0.2) (29.5
+0.5
)
-0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Dimensions in inches
(mm)
Common Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
50Ω
Level
Meter
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
50Ω
50Ω
Level
Meter
90
80
70
Insertion Loss (dB)
60
50
40
30
20
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
6 Amp
4 Amp
2 Amp
Insertion Loss (dB)
100
90
80
70
60
50
40
30
20
0
0.1
0.2
6 Amp
2 Amp
4 Amp
0.5
1
2
5
Frequency (MHz)
10
20
50
SPECTRUM CONTROL INC.
• 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Switched and Fused Filtered
Power Entry Modules
51