Click on Series name for product info on aimtec.com
Series AM2LS-NZ
2 Watt | DC-DC Converter
FEATURES:
•
•
•
•
SMD Package
Efficiency up to 86%
Unregulated
Industry Standard Pinout
•
Single Output Models
o
o
•
Operating temperature -40 C to +105 C
•
Input / Output Isolation 1500 & 3000 VDC
•
Continuous Short Circuit Protection for 1500VDC
models only
Models
Single output
Model
AM2LS-0503S-NZ
AM2LS-0505S-NZ
AM2LS-0509S-NZ
AM2LS-0512S-NZ
AM2LS-0515S-NZ
AM2LS-1205S-NZ
AM2LS-1209S-NZ
AM2LS-1212S-NZ
AM2LS-1215S-NZ
AM2LS-1224S-NZ
AM2LS-1515S-NZ
AM2LS-2405S-NZ
AM2LS-2409S-NZ
AM2LS-2412S-NZ
AM2LS-2415S-NZ
AM2LS-2424S-NZ
Input Voltage
(V)
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
13.5-16.5
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
Output
Voltage
(V)
3.3
5
9
12
15
5
9
12
15
24
15
5
9
12
15
24
Output
Current Max
(mA)
400
400
222
167
133
400
222
167
133
83
133
400
222
167
133
83
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Max
Capacitive
Load(uF)
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
Efficiency
(%)
71
79
82
82
83
79
82
82
83
84
83
79
82
82
83
86
AM2LS-0505SH30-NZ
4.5-5.5
5
400
3000
220
79
AM2LS-0509SH30-NZ
4.5-5.5
9
222
3000
220
82
AM2LS-0512SH30-NZ
4.5-5.5
12
167
3000
220
82
AM2LS-0515SH30-NZ
4.5-5.5
15
133
3000
220
83
AM2LS-1205SH30-NZ
10.8-13.2
5
400
3000
220
79
AM2LS-1212SH30-NZ
10.8-13.2
12
167
3000
220
82
AM2LS-1215SH30-NZ
10.8-13.2
15
133
3000
220
83
AM2LS-1224SH30-NZ
10.8-13.2
24
83
3000
220
84
AM2LS-1515SH30-NZ
13.5-16.5
15
133
3000
220
83
AM2LS-2405SH30-NZ
21.6-26.4
5
400
3000
220
79
AM2LS-2412SH30-NZ
21.6-26.4
12
167
3000
220
82
AM2LS-2415SH30-NZ
21.6-26.4
15
133
3000
220
83
AM2LS-2424SH30-NZ
21.6-26.4
24
83
3000
220
84
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
5
12
15
24
5
12
15
24
5 Vin
12 Vin
15 Vin
24 Vin
Typical
4.5-5.5
10.8-13.2
13.5-16.5
21.6-26.4
30
25
18
15
15
9
18
21
30
Capacitor
Tel: +1 514 620 2722
1 of 4
Maximum
Units
VDC
Quiescent Current
Reflected Input Ripple Current
Absolute Max Input (1sec max)
Filter
www.aimtec.com
F 051e R12.H
mA
mA
VDC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2LS-NZ
2 Watt | DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
60 sec
500VDC
1500 & 3000
>1000
20
Typical
Maximum
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Line voltage regulation
Conditions
100% load (see tolerance chart)
12 & 15 VDC input models 1500VDC models only
5 & 24 VDC Input models & 3000VDC models
For ±1% of Vin
3.3V models only
3.3V
5V
9V
12 V
15 V
24 V
100% load
At 20 MHz Bandwidth
Typical
±2.5
Continuous
Auto Recovery
Maximum
Units
%
1
±1.5
±1.2
18
12
9
8
7
6
±0.03
150
Sec
% of Vin
Load voltage regulation
(10% - 100% load)
%
Temperature coefficient
Ripple & Noise
%/ C
mV p-p
o
* Products with 5Vdc and 24Vdc input voltage; the supply voltage must be discontinued at the end of short circuit duration.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Cooling
Storage Humidity
Case material
Weight
Dimensions
(L x W x H)
MTBF
Maximum soldering temperature
Maximum case temperature
Conditions
100% load
With derating
3.3V & 5V above +71C
Others +85C
Typical
100
Maximum
300
-40 to +105
Units
KHz
o
C
C
-55 to +125
Free air convection
95
Epoxy resin (UL94-V0)
1500VDC models
1.4
3000VDC models
1.6
0.50 x 0.44 x 0.28 inches
12.70 x 11.20 x 7.25 mm
o
>3,500,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 C)
1.5mm from case for 10 sec
300
105
Non Condensing
o
% RH
g
o
o
C
C
Safety Specifications
Parameters
Standards
EN 55022, Class B, with external filter
IEC 61000-4-2, Contact ±8KV, Criteria B
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2LS-NZ
2 Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
3
4
5
6
7
8
Dimensions
Single Output Models
Front View
Side View
5.00
(0.19)
2.0
(0.08)
0º~10º angle
8.3
(0.32)
Single
Output
- V Input
+ V Input
No Pin
.-V Output
+V Output
No Pin
No Pin
N.C.
0.25
(0.01)
Top View
12.70
(0.50)
7.62
(0.30)
1.45
(0.06)
0.88
(0.04)
11.20 8.30
(0.44) (0.32)
1
2.54
(0.10)
0.60
(0.02)
Recommended Circuits (EMI Class B)
Capacitor selection Table
Vout
C3
3.3 V
10 µF
5V
10 µF
9V
4.7 µF
12 V
2.2 µF
15 V
1 µF
24V
0.47 µF
LDM
6.8µH
+V output
DC/DC
Converter
C1
4.7µF/
50V
C2
4.7µF/
50V
+V input
C3
Load
-V input
-V output
CY
24V input only
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2LS-NZ
2 Watt | DC-DC Converter
Load Accuracy Tolerance Graph
10 %
5%
Rated
Output
Voltage
Derating
Free Air Convection
71 ºC
Typic
al loa
d
line
100
+2.5 %
-2.5 %
-7.5 %
85 ºC
3.3V & 5V
Output Power %
80
60
50%
Output Voltage
Accuracy%
Safe Operating Area
Others
40
20
0
-50
-30
0
40
71C
85C
105C
70 %
10
%
50
%
Output Current % (Nominal Input)
100
%
80
100
120
Ambient Temperature
º C
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4
. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this
datasheet
.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.