POWERLINE - DC/DC-Converter
G-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
Features
●
40 Watts max. Output Power
●
2:1 Wide Input Voltage Range
●
International Safety Standard
Design
●
Six-Sided Continuous Shield
Selection Guide
24V and 48V Input Types
Part Number
Input
Voltage
VDC
RP40-243.3SG
RP40-2405SG
RP40-2412SG
RP40-2415SG
RP40-243.312TG
RP40-240512TG
RP40-243.315TG
RP40-240515TG
RP40-483.3SG
RP40-4805SG
RP40-4812SG
RP40-4815SG
RP40-483.312TG
RP40-480512TG
RP40-483.315TG
RP40-480515TG
18-36
18-36
18-36
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
36-75
36-75
36-75
Output
Voltage
VDC
3.3
5
12
15
3.3 / ± 12
5 / ± 12
3.3 / ± 15
5 / ± 15
3.3
5
12
15
3.3 / ± 12
5 / ± 12
3.3 / ± 15
5 / ± 15
●
●
●
●
High Efficiency up to 90%
Standard Package,
50.8 mm x 50.8 mm x 10.2 mm
Fixed Switching Frequency
UL 1950 Component Recognised
Output
Current
mA
8000
8000
3400
2700
6000 / ±400
6000 / ±400
6000 / ±300
6000 / ±300
8000
8000
3400
2700
6000 / ±400
6000 / ±400
6000 / ±300
6000 / ±300
Output
Ripple
& Noise
mVp-p
50
50
75
75
50 / 75
50 / 75
50 / 75
50 / 75
50
50
75
75
50 / 75
50 / 75
50 / 75
50 / 75
Input Current
(see note 4)
mA
1325
1961
2048
2008
1512
1989
1481
1958
655
969
1000
992
747
982
732
967
Efficiency
(see note 5)
%
87
89
88
88
85
87
85
87
88
90
89
89
86
88
86
88
Capacitive
Load
max.
µF
21000
13600
2360
1510
13000 / ±330
6800 / ±330
13000 / ±110
6800 / ±110
21000
13600
2360
1510
13000 / ±330
6800 / ±330
13000 / ±110
6800 / ±110
RP40-4805SG: Derating and Efficiency Curves, External Output Trimming
Derating Curve
125
100
75
Output Power (%)
Efficiency (%)
50
25
0
-40 -25 -10 0
50 60 70 80 90 100
Natural Convection
Efficiency vs Input Voltage
93
92
91
90
89
88
87
86
85
84
83
82
Efficiency vs Output Load
96
94
92
90
88
86
84
82
80
75
70
65
35
40
45
50
55
60
65
70
Efficiency (%)
1
2
3
4
5
6
7
8
Ambient Temperature Range (°C)
Input Voltage (V)
Output Load (A)
External Output Trimming
8
Trim
Up
9
Trim
Down
7
PO 68
August 2002
www.recom-international.com
POWERLINE - DC/DC-Converter
G-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
Specifications
(typical at nominal input and 25°C unless otherwise noted)
Output Power
Voltage Accuracy (full Load and nominal Vin)
Single / Dual
Triple Main
Auxilliary
40W max.
±1%
±1%
±5%
± 10%
Single & Triple
Dual (3.3V)
Single
Dual
Triple
10% of FL
800mA
±0.5%
±0.5%
±1%
±2%
±5%
See selection guide table
±0.02%/°C max.
400µsec
3.3V Output
5V Output
12V Output
15V Output
3.9V
6.2V
15V
18V
150% max.
Hiccup, Automatic Recovery
18-36VDC
36-75VDC
17.8VDC
16VDC
36VDC
34VDC
L-C Type
24V Input
48V Input
Nominal Vin and full load
50VDC
100VDC
40mAp-p
25ms typ.
DC-DC ON
DC-DC OFF
Nominal Vin
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
2.5 mA
1600VDC
10
9
Ω
1000pF
300kHz
UL 1950, EN60950
Nickel-Coated Copper
Non-conducted Black FR4
Epoxy (UL94-V0)
60g (2.11 oz)
50.8 x 50.8 x 10.2 mm
1.434 x 10
5
Hours
continued on next page
Voltage Adjustability (single output only)
Minimum Load Voltage (see note 1)
Line Regulation (LL-HL at FL)
Load Regulation (10% to 100% FL)
Main
Auxilliary
Ripple and Noise, 20MHz BW (measured with a 104pF/50V MLCC)
Temperature Coefficient
Transient Response Recovery Time (25% load step change)
Over Voltage Protection (zener diode clamp):
Over Load Protection (% of full load at nominal Vin)
Short Circuit Protection
Input Voltage Range
Under Voltage Lockout
24V types nominal input
48V types nominal input
24V Input
48V Input
Input Filter
Input Surge Voltage (100 ms max.)
Input Reflected Ripple (see note 2)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 3)
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
Remote off Input Current
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Approved to Safety Standards
Case Material
Base Material
Potting Material
Weight
Dimensions
MTBF (MIL-HDBK-217F, TA = 25°C full load)
www.recom-international.com
August 2002
PO 69
POWERLINE - DC/DC-Converter
G-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
Specifications continued
(typical at nominal input and 25°C unless otherwise noted)
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance
Thermal Shock
Vibration
Relative Humidity
Conducted Emissions
Radiated Emissions
Conducted Immunity
Radiated Immunity
Surge
Fast Transient
ESD Air
Notes:
1. The RP40 G-series requires a minimum of 10% loading on the output to maintain specified
regulation. Operation under no-load condition will not damage these devices, however
they may not meet all listed specification.
2. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
3. The ON/OFF control pin voltage is referenced to negative input.
4. Maximum value at nominal input voltage and full load.
5. Typical value at nominal input voltage and full load.
6. It will compensate for up to 0.5V line drop voltage between converter and load.
If remote sense is not being used, the +sense should be connected to its corresponding
+OUTPUT and likewise the –sense should be connected to its corresponding –OUTPUT.
-40°C to +85°C (with derating)
+100°C
-55°C to +105°C
Natural convection
9.2°C/Watt
MIL-STD-810D
10-55Hz, 2G, 3 Min. Period, 30 Min. along X, Y and Z
5% to 95% RH
EN55022
EN55022
EN61000-4-6
EN61000-4-3
EN61000-4-5
EN61000-4-4
EN61000-4-2
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Package Style and Pinning (mm)
50.80
29.20
10.20
3
2
1
5.10
10.20
Pin Connections
Pin #
Single
+Vin
-Vin
Ctrl
NC
-Sense
(see note 6)
+Sense
(see note 6)
+Vout
–Vout
Trim
Dual
+Vin
-Vin
Ctrl
3.3V
3.3V
RTN
NC
NC
5V
5V
RTN
Triple
+Vin
-Vin
Ctrl
+Aux
Common
–Aux
+Vout
–Vout
NC
dia.
1.0
Bottom
View
50.80
45.70
1
2
3
4
5
6
7
8
9
9
8
7
6
5
4
2.5
7.6
15.20
20.30
5.6
5.1
12.70
Pin Pitch Tolerance ±0.35 mm
PO 70
August 2002
www.recom-international.com