CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTES:
1.
θ
JA
is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach” features. See
Tech Brief TB379.
2. For
θ
JC
, the “case temp” location is the center of the exposed metal pad on the package underside.
Operating Specifications
Over the recommended operating conditions unless otherwise specified. Parameters with MIN and/or MAX
limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested
PARAMETER
Operating Voltage
Power-Up Condition 1
Power-Up Condition 2 Threshold
SYMBOL
V
CC
V
PORVCC
V
CC
voltage (Note 3)
V
POR123
V
CELL1
- V
SS
and V
CELL2
- V
CELL1
and
V
CELL3
- V
CELL2
(rising) (Note 3)
V
PORhys
V
CELL1
- V
SS
and V
CELL2
- V
CELL1
and
V
CELL3
- V
CELL2
(falling) (Note 3)
V
RGO
I
RGC
I
VCC1
I
RGO1
I
VCC2
I
RGO2
I
VCC3
I
RGO3
I
VCELL1
0µA < I
RGC
< 350µA
(Control current at output of RGC.
Recommend NPN with gain of 70+)
Power-up defaults, WKUP pin = 0V.
Power-up defaults, WKUP pin = 0V.
LDMONEN bit = 1, WKPOL bit = 1,
VWKUP = 10V, [AO3:AO0] bits = 03H.
LDMONEN bit = 1, WKPOL bit = 1,
VWKUP = 10V, [AO3:AO0] bits = 03H.
Default register settings, except
SLEEP bit = 1. WKUP pin = VCELL1
Default register settings, except
SLEEP bit = 1. WKUP pin = VCELL1
AO3:AO0 bits = 0000H
3.0
0.35
1.1
TEST CONDITION
MIN
9.2
4
1.7
TYP
MAX
30.1
9.2
2.3
UNIT
V
V
V
Power-Up Condition 2 Hysteresis
70
mV
3.3V Regulated Voltage
3.3VDC Voltage Regulator Control
Current Limit
V
CC
Supply Current
RGO Supply Current
V
CC
Supply Current
RGO Supply Current
3.3
0.50
3.6
V
mA
400
300
500
510
410
700
µA
µA
µA
450
650
µA
V
CC
Supply Current
RGO Supply Current
10
µA
1
µA
VCELL Input Current (V
CELL1
)
VCELL Input Current (V
CELLN
)
14
10
µA
µA
I
VCELLN
AO3:AO0 bits = 0000H
3
FN6719.0
July 3, 2008
ISL94201
Operating Specifications
Over the recommended operating conditions unless otherwise specified. Parameters with MIN and/or MAX
limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested
(Continued)
PARAMETER
SYMBOL
TEST CONDITION
MIN
TYP
MAX
UNIT
OVER-TEMPERATURE PROTECTION SPECIFICATIONS
Internal Temperature Shutdown
Threshold
Internal Temperature Hysteresis
T
INTSD
T
HYS
Temperature drop needed to restore
operation after over-temperature
shutdown.
125
°C
20
°C
Internal Over-temperature Turn On
Delay Time
External Temperature Output Current
External Temperature Limit Threshold
t
ITD
I
XT
T
XTF
Current output capability at TEMP3V pin
Voltage at V
TEMPI
; Relative to falling
edge
V TEMP3V
-----------------------------
-
128
ms
1.2
-20
0
+20
mA
mV
13
External Temperature Limit Hysteresis
External Temperature Monitor Delay
T
XTH
t
XTD
Voltage at V
TEMPI
.
Delay between activating the external
sensor and the internal over-temperature
detection.
TEMP3V is ON (3.3V)
60
110
1
160
mV
ms
External Temperature Autoscan
On-Time
External Temperature Autoscan
Off-Time
ANALOG OUTPUT SPECIFICATIONS
Cell Monitor Analog Output Voltage
Accuracy
Cell Monitor Analog Output External
Temperature Accuracy
t
XTAON
5
ms
t
XTAOFF
TEMP3V output is off.
635
ms
V
AOC
V
AOXT
[V
CELLN
- (V
CELLN-1
)]/2 - AO
External temperature monitoring accuracy.
Voltage error at AO when monitoring
TEMPI voltage (measured with
TEMPI = 1V)
-15
4
30
mV
-10
10
mV
Internal Temperature Monitor Output
Voltage Slope
Internal Temperature Monitor Output
AO Output Stabilization Time
V
INTMON
Internal temperature monitor voltage
change
T
INT25
t
VSC
Output at +25°C
From SCL falling edge at data bit 0 of
command to AO output stable within 0.5%
of final value. AO voltage steps from 0V to
2V. (C
AO
= 10pF) (Note 7)
-3.5
mV/°C
1.31
0.1
V
ms
WAKE UP/SLEEP SPECIFICATIONS
Device WKUP Pin Voltage Threshold V
WKUP1
WKUP pin rising edge (WKPOL = 1)
Device wakes up and sets WKUP flag
(WKUP Pin Active High - Rising Edge)
HIGH.
Device Wkup Pin Hysteresis
(WKUP Pin Active High)
V
WKUP1H
WKUP pin falling edge hysteresis
(WKPOL = 1) sets WKUP flag LOW (does
not automatically enter sleep mode)
R
WKUP
Resistance from WKUP pin to VSS
(WKPOL = 1)
130
3.5
5.0
6.5
V
100
mV
Input Resistance On WKUP
230
330
kΩ
Device WKUP Pin Active Voltage
Threshold (WKUP Pin Active Low -
Falling Edge)
V
WKUP2
WKUP pin falling edge (WKPOL = 0)
Device wakes up and sets WKUP flag
HIGH.
V
CELL1
- 2.6
V
CELL1
- 2.0 V
CELL1
- 1.2
V
4
FN6719.0
July 3, 2008
ISL94201
Operating Specifications
Over the recommended operating conditions unless otherwise specified. Parameters with MIN and/or MAX
limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization