8107 Paired - Low Capacitance Computer Cable for EIA RS-232/422 Applicatio
For more information please
call
1-800-Belden1
See Put-ups and Colors
Related Documents : No. 5 for
Paired Cables (Western
Electric Standard).pdf
Description:
24 AWG stranded (7x32) TC conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid shield (65%
coverage), 24 AWG stranded TC drain wire, PVC jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Pairs
Total Number of Conductors
AWG
Stranding
Conductor Material
INSULATION:
Insulation Material Trade Name
Insulation Material
Pair Color Code Chart :
Number
1
2
3
4
OUTER SHIELD:
Outer Shield Material Trade Name
Outer Shield Type
Outer Shield Material :
Layer Number
1
2
Outer Shield %Coverage
OUTER SHIELD DRAIN WIRE :
Page 1 of 3
7
14
24
7x32
TC - Tinned Copper
Datalene®
FPE - Foam Polyethylene
Color
White/Blue & Blue/White
White/Orange & Orange/White
White/Green & Green/White
White/Brown & Brown/White
Number
5
6
7
Color
White/Gray & Gray/White
Red/Blue & Blue/Red
Red/Orange & Orange/Red
Beldfoil®
Tape/Braid
Material Trade Name
Beldfoil®
Type
Tape
Braid
100 %
Material
Aluminum Foil-Polyester
Tape w/Shorting Fold
TC - Tinned Copper
% Coverage (%)
100
65
8107 Paired - Low Capacitance Computer Cable for EIA RS-232/422 Applicatio
Outer Shield Drain Wire AWG
Outer Shield Drain Wire Stranding
Outer Shield Drain Wire Conductor Material
OUTER JACKET:
Outer Jacket Material
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
UL Temperature Rating
Bulk Cable Weight
Max. Recommended Pulling Tension
Min. Bend Radius (Install)
24
7x32
TC - Tinned Copper
PVC - Polyvinyl Chloride
.341 in.
-30°C To +80°C
80°C (UL AWM Style 2919)
62.5 lbs/1000 ft.
82.5 lbs.
3.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CEC/C(UL) Specification
AWM Specification
EU CE Mark (Y/N)
EU RoHS Compliant (Y/N)
EU RoHS Compliance Date (mm/dd/yyyy):
FLAME TEST:
UL Flame Test
PLENUM/NON-PLENUM:
Plenum (Y/N)
Plenum Number
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance
Nom. Capacitance Conductor to Conductor @ 1 KHz
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz
Nominal Velocity of Propagation
Nom. Conductor DC Resistance @ 20 Deg. C
Nominal Outer Shield DC Resistance @ 20 Deg. C
Max. Operating Voltage - UL
Max. Recommended Current
NOTES:
Page 2 of 3
CM
CM
UL Style 2919 (30 V 80°C)
Yes
Yes
01/01/2004
UL1685 UL Loading
N
88107
100 Ohms
12.5 pF/ft
22 pF/ft
78 %
24 Ohms/1000 ft
3.5 Ohms/1000 ft
30 V RMS (UL AWM Style 2919), 300 V RMS
1.5 Amps per conductor @ 25°C
8107 Paired - Low Capacitance Computer Cable for EIA RS-232/422 Applicatio
Notes
Datalene® insulation features include low dielectric constant and a dissipation
factor for high-speed, low-distortion data handling. Physical properties include
good crush resistance and light weight.
PUT-UPS AND COLORS:
Item
Description
8107 060100
7 PR #24 FHDPE SH
PVC
8107 0601000
7 PR #24 FHDPE SH
PVC
8107 060500
7 PR #24 FHDPE SH
PVC
C = CRATE REEL PUT-UP.
Revision Number: 1
Put-Up (ft.)
100
1000
500
Ship Weight (lbs.)
6.8
63
33
Jacket Color
CHROME
CHROME
CHROME
Notes
C
C
Revision Date: 07-22-2005
© Copyright 2006 Belden, Inc
All Rights Reserved.
Although Belden ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment
For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-
2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU
ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-
2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the
Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information
provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product
itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory
information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations
based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3