R F
C o m p o n e n t s
May 2015
Multilayer Phase Shifter (Delay Line)
For 1710-1910MHz
DEA101910DT-6006B1
1.0x0.5mm [EIA 0402]*
* Dimensions Code JIS[EIA]
RF Components
Multilayer Phase Shifter (Delay Line)
For 1710-1910MHz
Conformity to RoHS Directive
DEA101910DT-6006B1
SHAPES AND DIMENSIONS
[Top view]
1.00±0.05
(4)
0.50±0.05
0.52max.
(1)
(3)
(2)
Marking
[Bottom view]
0.12±0.07
0.30±0.10
0.30±0.10
Terminal functions
1 IN
2 GND
3 OUT
4 GND
0.12±0.07
0.35±0.10
Dimensions in mm
RECOMMENDED LAND PATTERN
0.70
0.30
0.45
0.20
0.45
RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://product.tdk.com/en/environment/rohs/
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20150508 / rf_phase-shifter_dea101910dt-6006b1_en.fm
0.30
Dimensions in mm
RF Components
DEA101910DT-6006B1
ELECTRICAL CHARACTERISTICS
Item
Insertion Loss (dB)
Phase Shift (deg.)
VSWR
Characteristic Impedance (:)
・
Ta=25±5°C
Frequency Range
(MHz)
1710 to 1910
1710 to 1910
1710 to 1910
Min.
—
–105
—
Typ.
—
—
—
50 (Nominal)
Max.
0.75
–75
1.9
TEMPERATURE RANGE
Operating temperature
(°C)
–40 to +85
Storage temperature
(°C)
–40 to +85
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20150508 / rf_phase-shifter_dea101910dt-6006b1_en.fm
RF Components
DEA101910DT-6006B1
FREQUENCY CHARACTERISTICS
INSERTION LOSS
0.0
ATTENUATION
0
5
0.5
10
15
Attenuation(dB)
1000
1500
2000
Frequency (MHz)
2500
3000
20
25
30
35
40
45
Insertion Loss (dB)
1.0
1.5
2.0
2.5
3.0
500
50
3000
4000
5000
6000
Frequency (MHz)
7000
8000
VSWR
2.0
1.9
1.8
PHASE SHIFT
200
150
100
1.7
1.6
Phase Shift(deg.)
50
0
–50
–100
VSWR
1.5
1.4
1.3
1.2
1.1
1.0
500
1000
1500
2000
Frequency (MHz)
2500
3000
–150
–200
500
1000
1500
2000
Frequency (MHz)
2500
3000
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20150508 / rf_phase-shifter_dea101910dt-6006b1_en.fm
RF Components
DEA101910DT-6006B1
RECOMMENDED REFLOW PROFILE
Soaking
Working
Soldering
Peak
T4
T5
T4
T3
T:
Temperature
T3
T2
T1
t1
t3
t2
t:
Time
Soaking
Temp.
T1
150°C
T2
180°C
Time
t1
60 to 120s
Working
Temp.
T3
230°C
Time
t2
more than 30s
Soldering Peak
Temp.
T4
247 to 253°C
Time
t3
within 10s
Temp.
T5
260°C max.
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20150508 / rf_phase-shifter_dea101910dt-6006b1_en.fm