16-2-15
High speed response: 2.5 ms
or less
With anti-chattering function
Stable switch output is possible even with sudden
Anti-chattering function
Devices such as large bore cylinders and high-flow vacuum
ejectors consume a large volume of air when they operate, and
this may cause a momentary drop in the primary pressure. This
function prevents such momentary pressure drops from being
detected as abnormal pressures by allowing the response time
selection to be changed.
[Selectable response times: t]
2.5 ms (normal), 24 ms, 192 ms or 768 ms
The normal setting is selected when shipped from the factory.
(Operating principle)
The pressure values measured within the user-selected response
time are averaged, and switch output (ON/OFF) is determined by
comparing this averaged pressure value with the set pressure.
Pressure
→
Momentary change
Set value P1
P2
Time
→
t (ms)
(Averaging)
Switch output ON
operation
when normal OFF
Time
→
Switch output
operation when ON
anti-chattering
OFF
function is used
Time
→
t (ms)
(Averaging)
With auto shift function
Allows switch output unaffected by variations in
primary pressure.
Auto shift function
Erroneous operation may occur if there is fluctuation in the
primary pressure.
The auto shift function compensates for pressure changes to
ensure proper ON/OFF switch response during such fluctuations.
(Operating principle)
At the point when the primary pressure fluctuates, the set
pressure value is compensated by setting the auto shift input
(external input) to low (no-voltage) input, using the pressure
measured at that point as a standard.
Without using auto shift
When the primary pressure fluctuates, a correct determination becomes impossible.
Pressure
→
Primary pressure normal Primary pressure drop
Primary pressure increase
P1
Set value
P2
Time
→
Switch output ON
1, 2
OFF
Does not turn ON
Does not turn OFF
Time
→
When using auto shift
Set value compensation Set value compensation
Pressure
→
P1
P2
Time
→
Switch output ON
1, 2
OFF
Time
→
Switch output response time
when auto shift is input.
Compound pressure (ZSE40F)
Able to detect suction pressure (vacuum
pressure) and release pressure (positive
pressure) with a single pressure switch.
Set value
Primary pressure normal Primary pressure drop Primary pressure increase
5 ms or more
Auto shift
input
Hi
Lo
10 ms
or less
[
]
3 types of piping
Different piping methods are
possible to accommodate the
installation location.
Time
→
Repeatability
±0.2%
F.S.
±1
digit or less
IP65 compatible
Dusttight/Splash proof type
16-2-16
High Precision,
Digital Pressure Switch
Series
ZSE40/ISE40
How to Order
Set pressure range
Nil
–0.100 to 1.000 MPa
For positive pressure
For positive pressure
For vacuum/compound pressure
ISE40
ZSE40
01
01
22
22
ZSE
ISE
PSE
Z
I
SE3
Set pressure range
Nil
F
10.0 to –101.3 kPa For vacuum pressure
–100.0 to 100.0 kPa For compound pressure
Option
Nil
None
Bracket A
(ZS-24-A)
PS
Z
I
SE
1
2
A
ZSP
ISA2
Bracket B
(ZS-24-B)
Piping specifications
01:
R 1/8 (With M5 female threads)
W1:
Rc 1/8
T1:
NPT 1/8 (With M5 female threads)
R 1/8, NPT 1/8
IS
ZSM
PF2
Reverse pressure
two directions
B
Rc 1/8
M5 x 0.8 female threads
Rc 1/8
Panel mount
(ZS-22-A)
IF
Data
E
∗
C4:
With ø4 One-touch fitting
∗
C6:
With ø6 One-touch fitting
Wall mount
∗
M5:
M5 x 0.8 (Female threads)
Wall mount
Panel mount
(ZS-24-C)
+ Front protective cover
M5 x 0.8
ø4, ø6
One-touch fitting
F
∗
Option
∗
When optional parts only are
required, order with the part
numbers inside ( ).
Input/Output specifications
22
30
∗
62
∗
70
∗
∗
Option
NPN open collector 2 outputs + analog output
NPN open collector 2 outputs + auto shift input
PNP open collector 2 outputs + analog output
PNP open collector 2 outputs + auto shift input
Unit specifications
With unit switching function
Note1)
SI unit only
Note 2)
M
Note 1) This will no longer be sold for use in
Japan after the new Weight and
Measure Act is implemented
(October,1999).
Note 2) Fixed unit
For vacuum/compound pressure: kPa
For positive pressure: MPa
Nil
Note
When equipped with auto shift function, the following ranges can be set.
Set pressure range
–100.0 to 100.0 kPa
10.0 to –101.3 kPa
–0.1 to 1.000 MPa
Setting range
–100.0 to 100.0 kPa
–101.3 to 101.3 kPa
–1.000 to 1.000 MPa
Lead wire length
Nil
L
0.6 m
3m
16-2-17
Series
ZSE40/ISE40
ZSE40F
(Compound pressure)
–100.0 to 100.0 kPa
–100.0 to 100.0 kPa
500 kPa
0.1
—
0.001
0.001
0.02
ZSE40
(Vacuum pressure)
0.0 to –101.3 kPa
10.0 to –101.3 kPa
ISE40
(Positive pressure)
0.000 to 1.000 MPa
–0.100 to 1.000 MPa
1.5 MPa
—
0.001
0.01
0.01
0.1
—
—
Specifications
Rated pressure range
Operating pressure range/Set pressure range
Withstand pressure
kPa
MPa
kgf/cm
2
bar
psi
mmHg
InHg
Set pressure
resolution
Note 1)
Applicable fluid
Power supply voltage
Current consumption
Switch output
Repeatability
Hysteresis mode
Hysteresis
Window comparator mode
Response time (With anti-chattering function)
Output short circuit protection
Display
Display accuracy
0.01
1
0.1
Air, Non-corrosive/Non-flammable gas
12 to 24 VDC
±10%,
Ripple (p-p) 10% or less
55 mA or less
NPN or PNP 2 outputs Max. load current : 80 mA
Max. applied voltage: 30 VDC (With NPN output)
Residual voltage
: 1 V or less (With 80 mA load current)
±0.2%
F.S.
±1digit
or less
Variable
Fixed (3 digits)
Note4)
2.5 ms or less (With anti-chattering function: 24 ms, 192 ms and 768 ms selections)
Yes
3 1/2 digit LED display (Sampling cycle: 5 times/sec.)
±2%
F.S.
±1
digit or less (at ambient temperature of 25
±3°C)
Indicator light
Green LED (OUT1: Lights when ON), Red LED (OUT2: Lights when ON)
Output voltage: 1 to 5 V
Output voltage: 1 to 5 V
±2.5%
F.S. or less (in rated pressure range)
±5%
F.S. or less (in rated pressure range)
Analog output
Note 2)
Linearity:
±1%
F.S. or less
Linearity:
±1%
F.S. or less
Output impedance: Approx. 1 kΩ
Output impedance: Approx. 1 kΩ
Note 3)
No-voltage input (Reed or solid state), input 5 ms or more
Auto shift input
IP65
Enclosure
Ambient temperature range
Operating: 0 to 50˚C, Stored: –10 to 60˚C (No condensation or freezing)
Ambient humidity range
Operating/Stored: 35 to 85% RH (No condensation)
Environmental
Withstand voltage
1000 VAC for 1 min. between lead wires and body
resistance
Insulation resistance
50 MΩ or more (at 500 VDC) between lead wires and body
10 to 500 Hz at the smaller of amplitude 1.5 mm or acceleration 98 m/s
2
(10 G) in X, Y, Z directions for 2 hrs. each (De-energized)
Vibration resistance
Impact resistance
980 m/s
2
(100 G) in X, Y, Z directions 3 times each (De-energized)
In a temperature range of 0 to 50°C,
±2%
F.S. or less of pressure measured at 25°C
Temperature characteristics
01: R 1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc 1/8
C4: With ø4 One-touch fitting, C6: With ø6 One-touch fitting, M5: M5 female threads
5-wire oil resistant heavy-duty cord (0.15 mm
2
)
Lead wire
01/T1 types approx. 60 g, W1 type approx. 80 g, C4/C6/M5 types approx. 92 g (Each including 0.6 m lead wires)
Weight
Note)
Note 1) Equipped with unit switching function
When equipped with auto shift function, the following ranges can be set.
(Types without the unit switching function use SI units (kPa or MPa) only.)
Note 2) For ZSE40 (F)/ISE40--
22
62
Set pressure range
Setting range
Note 3) For ZSE40 (F)/ISE40--
30
70
–100.0 to 100.0 kPa
–100.0 to 100.0 kPa
Note 4) For ZSE40F (compound pressure) with “psi” indication, this is 0.03 to 0.04
10.0 to –101.3 kPa
–101.3 to 101.3 kPa
psi.
– 0.1 to 1.000 MPa
–1.000 to 1.000 MPa
Note 5) For ZSE40F (compound pressure) with “psi” indication, zero clear is in the
range of
±0.01
psi.
Port size
Example of Internal Circuit and Wiring
ZSE40(F)
ISE40--22(L)-(M)
Main circuit
DC (+)
(Brown)
1 kΩ
ZSE40(F)
ISE40--62(L)-(M)
Load
Main circuit
Load
With analog output
DC (–)
(Blue)
DC (–)
(Blue)
Load
ZSE40(F)
ISE40--30(L)-(M)
Main circuit
1.2 kΩ
6.8 kΩ
Main circuit
Load
With auto shift input
DC (–)
(Blue)
DC (–)
(Blue)
16-2-18
Load
Load
DC (+)
(Brown)
Auto shift input
(Gray)
OUT1
(Black)
OUT2
(White)
ZSE40(F)
ISE40--70(L)-(M)
With auto shift input
12 to 24 VDC
1.2 k
Ω
6.8 k
Ω
DC (+)
(Brown)
Auto shift input
(Gray)
OUT1
(Black)
OUT2
(White)
12 to 24 VDC
Load
Analog output
(Gray)
OUT1
(Black)
OUT2
(White)
With analog output
12 to 24 VDC
1 k
Ω
DC (+)
(Brown)
Analog output
(Gray)
OUT1
(Black)
OUT2
(White)
12 to 24 VDC
Load
High Precision,
Digital Pressure Switch
Description
3 1/2-digit LED
Displays present pressure.
Displays each mode.
Displays error mode.
Series
ZSE40/ISE40
kPa
LED (Green)
Displays OUT1 output condition
When it is ON, the LED is
illuminated.
OUT1
OUT2
LED (Red)
SET
Displays OUT2 output condition.
When it is ON, the LED is
illuminated.
UP button
Switching of the mode and set value
DOWN button
Switches the mode and set value.
ZSE
ISE
PSE
Z
I
SET button
Switches to each mode and fixes
the set value.
SE3
PS
Z
I
SE
1
2
ZSP
ISA2
IS
Calibration Procedures
Setting procedure
ZSM
PF2
IF
Manual
pressure setting
Enter the set value of the
pressure to perform switch
output.
Zero clear
Adjusts the zero point of the
atmospheric pressure.
Key lock
mode
Mode is not switched, even if
the button is pressed during
operation.
Data
Initial setting
Set “Output mode”, “Response
time” and “Auto or Manual
mode”.
Auto
preset
Automatically sets the pressure
for the adsorption confirmation
or
supply
pressure
confirmation.
Manual
pressure setting
Allows fine-tuning of the
data set automatically by
auto preset.
Normal operation
Measured pressure is
displayed and the switch
operation begins.
16-2-19