760241065 | C-012-LA-8G-M12BK/20G/B
TeraSPEED® Indoor/Outdoor, Single Jacket/Single Armor, Low Smoke
Zero Halogen (LSZH), Gel Filled , Stranded Loose Tube Cable
l
Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber indoor/outdoor cable
EMEA
Standards And Qualifications
EN50575 CPR Cable EuroClass
Cable Qualification Standards
B2ca | s1 | s1a | d0
EN 187105 | IEC 60794-1-2
Representative Image
General Specifications
Construction Type
Cable Type
Subunit Type
Armored
Stranded loose tube
Gel-filled
Construction Materials
Fiber Type Solution
Total Fiber Count
G.657.A2
12
page 1 of 3
March 30, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 9, 2019
760241065 | C-012-LA-8G-M12BK/20G/B
Armor Type
Fiber Type
Fiber Type, quantity
Fibers per Subunit, quantity
Jacket Color
Jacket UV Resistance
Corrugated steel
G.657.A2
12
12
Black
UV stabilized
Dimensions
Buffer Tube/Subunit Diameter
Cable Weight
Diameter Over Jacket
Subunit, quantity
2.00 mm | 0.08 in
199.4 kg/km | 134.0 lb/kft
12.30 mm | 0.48 in
6
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
20.0 cm | 7.9 in
13.3 cm | 5.2 in
Tensile Load, long term, maximum
800 N | 180 lbf
Tensile Load, short term, maximum
2700 N | 607 lbf
Vertical Rise, maximum
432.0 m | 1416.0 ft
Flame Test Specifications
Flame Test Method
IEC 60332-1-2 | IEC 60754-2 | IEC 61034-2
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Aerial, lashed | Buried | Low Smoke Zero Halogen (LSZH)
-30 °C to +60 °C (-22 °F to +140 °F)
-40 °C to +70 °C (-40 °F to +158 °F)
-40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
Impact Test Method
Strain
Strain Test Method
250 lb/in | 44 N/mm
IEC 60794-1 E3
35 cycles
IEC 60794-1 E6
7.38 ft lb | 10.00 N-m
IEC 60794-1 E4
See long and short term tensile loads
FOTP-33 | IEC 60794-1 E1
page 2 of 3
March 30, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 9, 2019
760241065 | C-012-LA-8G-M12BK/20G/B
Twist
Twist Test Method
Water Penentration
Water Penentration Test Method
10 cycles
IEC 60794-1 E7
24 h
IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze
Cable Freeze Test Method
Heat Age
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-2 °C | 28 °F
IEC 60794-1 F15
-40 °C to +85 °C (-40 °F to +185 °F)
IEC 60794-1 F9
-30 °C to +60 °C (-22 °F to +140 °F)
IEC 60794-1 E11
-40 °C to +70 °C (-40 °F to +158 °F)
IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
CENELEC
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
EN 50575 compliant, Declaration of Performance (DoP) available
Included Products
CS -8G-LT (Product Component—not orderable)
—
Enhanced Low Macrobending, Zero Water Peak, Dispersion-Unshifted Singlemode
CS-8G-
Component—
Dispersion-
Fiber (ITU-T G.657.A2, B2)
(ITU-
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 30, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 9, 2019