*Results may vary. Additional terms and conditions, including the limited warranty, apply at the time of purchase.
See the warranty details and enclosed information for applicable operating and use requirements.
Page 1
Document number: 3000246.5
maxwell.com
DATASHEET
160V MODULE
PRODUCT SPECIFICATIONS (Cont’d)
MONITORING / CELL VOLTAGE MANAGEMENT
Internal Temperature Sensor
Temperature Interface
Cell Voltage Monitoring
Connector
Cell Voltage Management
BMOD0006 E160 B02
N/A
N/A
Voltage Center Tap
M4
Passive
2,500 W/kg
5,100 W/kg
4 Wh/kg
21 Wh
POWER AND ENERGY
Usable Specific Power, P
d 4
Impedance Match Specific Power, P
max5
Specific Energy, E
max6
Stored Energy, E
stored
7
SAFETY
Short Circuit Current, typical
(Current possible with short circuit from rated voltage.
Do not use as an operating current.)
670 A
RoHS
5,600 VDC
Certifications
High-Pot Capability
10
TYPICAL CHARACTERISTICS
THERMAL CHARACTERISTICS
Thermal Resistance (R
ca
, All Cell Cases to Ambient), typical
8
Thermal Capacitance (C
th
), typical
Maximum Continuous Current (∆T = 15 °C)
8
Maximum Continuous Current (∆T = 40 °C)
8
1.1°C/W
4,800 J/°C
7 A
RMS
12 A
RMS
LIFE
DC Life at High Temperature
1
(held continuously at Rated Voltage and Maximum Operating Temperature)
1,500 hours
20%
100%
10 years
20%
100%
4 years
Capacitance Change
(% decrease from minimum initial value)
ESR Change
(% increase from maximum initial value)
Projected DC Life at 25°C
1
(held continuously at Rated Voltage)
Capacitance Change
(% decrease from minimum initial value)
ESR Change
(% increase from maximum initial value)
Shelf Life
(Stored uncharged at 25°C)
Page 2
Document number: 3000246.5
maxwell.com
DATASHEET
160V MODULE
ESR AND CAPACITANCE VS TEMPERATURE
180%
170%
160%
150%
140%
130%
120%
110%
100%
90%
80%
-60
-40
-20
0
20
40
60
80
Temperature (°C)
Capacitance
DC ESR
NOTES
1. Capacitance and ESR
DC
measured at 25°C using specified
test current per waveform below.
2. Absolute maximum voltage, non-repeated. Not to exceed
1 second.
3. After 72 hours at rated voltage. Initial leakage current can
be higher.
4. Per IEC 62391-2, P
d
=
5. P
max
=
6. E
max
=
V
2
4 x ESR
DC
x mass
½ CV
3,600 x mass
2
2
7. E
stored
= ½ CV
3,600
Percentage change from value at 25°C
8. ∆T=I
RMS2
x ESR x R
ca
9. Per United Nations material classification UN3499, all
Maxwell ultracapacitors have less than 10 Wh capacity
to meet the requirements of Special Provisions 361.
Both individual ultracapacitors and modules composed
of those ultracapacitors shipped by Maxwell can be
transported without being treated as dangerous goods
(hazardous materials) under transportation regulations.
10. Duration = 60 seconds. Not intended as an operating
parameter.
0.12V
2
ESR
DC
x mass
Page 3
Document number: 3000246.5
maxwell.com
DATASHEET
160V MODULE
MARKINGS
MOUNTING RECOMMENDATIONS
Please refer to the user manual for installation recommendations. Products are marked with the following information:
Rated capacitance, rated voltage, product number, name of
manufacturer, positive and negative terminal, warning marking,
serial number.
BMOD0006 E160 B02
Part Description
BMOD0006 E160 B02
L (
±
0.5mm)
367
Dimensions (mm)
W (
±
0.2mm)
235
H (
±
0.7mm)
79
Package Quantity
3
Product dimensions are for reference only unless otherwise identified. Product dimensions and specifications may change without notice.
Please contact Maxwell Technologies directly for any technical specifications critical to application. All products featured on this datasheet are covered by the following
U.S. patents and their respective foreign counterparts: 6643119, 7295423, 7307830, 7342770, 7352558, 7384433, 7440258 , 7492571, 7508651, 7791860, 7791861, 7859826,
7883553, 7935155, 8072734, 8279580, and patents pending.
Maxwell Technologies, Inc.
Global Headquarters
3888 Calle Fortunada
San Diego, CA 92123
USA
Tel: +1 858 503 3300
Fax: +1 858 503 3301
Maxwell Technologies SA
Route de Montena 65
CH-1728 Rossens
Switzerland
Tel: +41 (0)26 411 85 00
Fax: +41 (0)26 411 85 05
Maxwell Technologies, GmbH
Leopoldstrasse 244
80807 München
Germany
Tel: +49 (0)89 / 4161403 0
Fax: +49 (0)89 / 4161403 99
Maxwell Technologies
Shanghai Trading Co. Ltd.
Unit A2,C 12th Floor
Huarun Times Square
500 Zhangyang Road,
Pudong New Area
Shanghai 200122,
P.R. China
Phone: +86 21 3852 4000
Fax: +86 21 3852 4099
Maxwell Technologies Korea Co., Ltd.
Room 1524, D-Cube City
Office Tower, 15F #662
Gyeongin-Ro, Guro-Gu,
Seoul, 152-706
South Korea
Phone: +82 10 4518 9829
MAXWELL TECHNOLOGIES, MAXWELL, MAXWELL CERTIFIED INTEGRATOR, ENABLING ENERGY’S FUTURE, BOOSTCAP, C CELL, D CELL and their respective
designs and/or logos are either trademarks or registered trademarks of Maxwell Technologies, Inc. and may not be copied, imitated or used, in whole or in
SynQor推出超小的病人全接触型400W医疗电源模块,该电源模块的封装为3×5×1.44,功率密度高达18.3W/立方英寸,转换效率达91%。 SynQor通过推出首款专门针对医疗应用而研制的AC/DC电源模块,使得公司的多元化战略持续成功地延伸至新的医疗领域。ACuQor模块系列实现了在3×5×1.44有限尺寸上提供400W的有用功率。SynQor可以提供48V,36V or 24V的...[详细]