SB6G, SBT6G SERIES
Single Phase 6.0 AMPS. Glass Passivated Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
6.0 Amperes
SBT-6
SB-6
Features
UL Recognized File # E-96005
Glass passivated junction
Surge overload rating 175 amperes peak
Low forward voltage drop
Mounting position: Any
High temperature soldering guaranteed:
260℃ / 10 seconds / 0.375” ( 9.5mm )
lead length at 5 lbs., ( 2.3 kg ) tension
Small size, simple installation
Leads solderable per MIL-STD-202
Method 208
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number
SB
SB
SB
SB
SB
SB
SB
601G 602G 603G 604G 605G 606G 607G
Symbol
SBT SBT SBT SBT SBT SBT SBT
601G 602G 603G 604G 605G 606G 607G
Units
V
V
V
A
A
V
uA
uA
℃/W
℃
℃
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
@T
A
= 50℃
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 3.0A
Maximum DC Reverse Current @ T
A
=25℃
at Rated DC Blocking Voltage @ T
A
=125℃
Typical Thermal Resistance (Note 1)
(Note 2)
Operating Temperature Range
Storage Temperature Range
V
RRM
V
RMS
V
DC
I
(AV)
I
FSM
V
F
I
R
R
θ
JA
R
θ
JL
T
J
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
6.0
175
1.1
10
500
22
7.3
-55 to +150
-55 to +150
T
STG
Notes: 1. Unit Mounted on P.C.B. at 0.375” (9.5mm) Lead Length with 0.5 x 0.5” (12 x 12mm)
Copper Pads.
2. Unit Mounted on 2” x 3” x 0.25” Al. Plate.
- 740 -
RATINGS AND CHARACTERISTIC CURVES ( SB601G THRU SB607G )
SBT601G
SBT607G
FIG.1- MAXIMUM NON-REPETITIVE FORWARD SURGE
CURRENT PER BRIDGE ELEMENT
FIG.2- TYPICAL FORWARD CURRENT DERATING
CURVE
250
10
PEAK FORWARD SURGE CURRENT. (A)
AVERAGE FORWARD OUTPUT
CURRENT AMPERES
60 80 100
200
175
150
8
6
100
4
50
2
0
1
2
4
6
8 10
20
40
0
0
50
o
100
150
NUMBER OF CYCLES AT 60Hz
AMBIENT TEMPERATURE. ( C)
FIG.3- TYPICAL FORWARD CHARACTERISTICS
PER BRIDGE ELEMENT
100
FIG.4- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
100
INSTANTANEOUS FORWARD CURRENT AMPERES
INSTANTANEOUS REVERSE CURRENT, MICROAMPERES
10
TJ=125
0
C
10
1
Tj=25 C
PULSE WIDTH-300 S
1% DUTY CYCLE
0.1
0
1
TJ=25
0
C
0.01
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0.1
FORWARD VOLTAGE. VOLTS
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
140
- 741 -