2026-30A1FLF

产品描述Surge Protection Circuit, ROHS COMPLIANT PACKAGE
产品类别无线/射频/通信    电信电路   
文件大小536KB,共3页
制造商Bourns
官网地址http://www.bourns.com
标准
下载文档 详细参数 全文预览

2026-30A1FLF概述

Surge Protection Circuit, ROHS COMPLIANT PACKAGE

2026-30A1FLF规格参数

参数名称属性值
是否无铅不含铅
是否Rohs认证符合
零件包装代码MODULE
包装说明,
针数3
Reach Compliance Codecompli
JESD-30 代码O-XXSS-P3
JESD-609代码e3
湿度敏感等级1
功能数量1
端子数量3
最高工作温度90 °C
最低工作温度-40 °C
封装主体材料UNSPECIFIED
封装形状ROUND
封装形式SPECIAL SHAPE
峰值回流温度(摄氏度)NOT SPECIFIED
认证状态Not Qualified
表面贴装NO
电信集成电路类型SURGE PROTECTION CIRCUIT
温度等级INDUSTRIAL
端子面层Tin (Sn)
端子形式PIN/PEG
端子位置UNSPECIFIED
处于峰值回流温度下的最长时间NOT SPECIFIED
Base Number Matches1

文档预览

下载PDF文档
*R
oH
V E S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced TRIGARD
®
Approximately 8 mm diameter, 11 mm long
UL recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Model No.
2026-20
200 V
425 V
625 V
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2026-07
75 V
275 V
700 V
2026-09
90 V
275 V
600 V
2026-15
150 V
350 V
575 V
2026-23
230 V
450 V
650 V
2026-25
250 V
475 V
700 V
2026-26
260V
1
475 V
700 V
2026-30
300 V
500 V
775 V
2026-35
350 V
625 V
875 V
Model No.
2026-40
2026-42
400 V
420 V
675 V
925 V
725 V
1000 V
2026-47
470 V
800 V
1100 V
2026-60
600 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/µs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
2
.................................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20 µs
3
.................................................... 1 operation minimum
20000 A, 8/20 µs ...................................................... > 10 operations
5000 A, 10/350 µs ................................................... 1 operation
1000 A, 10/1000 µs ................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
3
............................................... 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Optional Switch-Grade Fail-short device available.
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >10
8
Ω
(-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
1
2
3
Tube meets BT requirement Type 14 A/1 (210-310 V).
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
大侠门帮帮忙!为什么总蓝屏啊!
大侠门帮帮忙!为什么总蓝屏啊!我自己想写个通过eprocess来查找进程路径的程序!可是几翻努力,换来的还是蓝屏,请你们帮帮我,我把我的实验代码附上!!! #include PCWSTR Get ......
msy2009 嵌入式系统
PCB 手册:《利用自动验证消除原理图设计错误》|Mentor 有奖活动
关于手册 当今的复杂设计已经不允许手动评审和验证原理图。Xpedition 原理图完整性分析可在进行原理图输入的同时,提供全自动原理图验证,因此可确保对原理图上的所有网络执行完整的检查,减少 ......
EEWORLD社区 PCB设计
【求助】430F1232无法debug
log文件显示write flash completed,但是无法debug。每次进入debug界面之前,提示无法设置断点,必须单步执行程序。可是我并没有设置断点,而且就算单步执行程序,也会报错:Una××e to execute ......
charlin 微控制器 MCU
6ull mini板尺寸
A:6ull mini板的具体尺寸数值有吗? B: 6.5*9cm ...
明远智睿Lan 工业自动化与控制
来给这个“新宝宝”起个名字吧~~~~
购物体验专区:https://bbs.eeworld.com.cn/forum-117-1.html 觉得目前的“购物体验专区”不够酷,大家给给建议 抛抛你的神奇点子。:victory: ...
soso 聊聊、笑笑、闹闹
PCB封装该
刚学习PCB画图,我自己画好一个元件的封装后,怎么调用该封装。...
inpopup PCB设计

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1286  1704  1512  1384  2680  27  16  51  1  3 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved