OLM100-1005 | OLM100
LINEAR MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
OLM100-1005
Other models and accessories
www.sick.com/OLM100
Part no.
1046580
Detailed technical data
Performance
Resolution
Repeatability
Output time
Light source
Measurement range
Max. movement speed
Sensing distance
Bar code width
1)
2)
0.1 mm, 1 mm
1 mm
1)
5 ms
LED, red
0 m ... 10,000 m
2)
4 m/s
100 mm, ± 20 mm
30 mm
Statistical error 1 σ.
Dependent on the set resolution and transfer protocol.
Interfaces
Data interface
RS-485
Mechanics/electronics
Supply voltage V
s
Ripple
Power consumption
Initialization time
Housing material
Weight
1)
2)
DC 10 V ... 30 V
1)
≤ 5 V
pp
2)
< 3 W
< 3 s
Magnesium
Zinc
Approx. 168 g
Limit values, reverse-polarity protected.
May not exceed or fall below U
v
tolerances.
Ambient data
Enclosure rating
1)
2)
3)
IP 65 (EN 60 529)
Temperatures < –20 °C with 5 min warm up time.
Max. 95 % humidity, non-condensing.
Typ. value at +25 °C ambient temperature.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-05-02 22:08:07
Subject to change without notice
LINEAR MEASUREMENT SENSORS
Protection class
Electromagnetic compatibility (EMC)
Ambient temperature
Typ. Ambient light immunity
Vibration resistance
Shock resistance
1)
2)
3)
OLM100-1005 | OLM100
III
EN 61000-6-2
EN 61000-6-4
Operation: –30 °C ... +60 °C
≤ 30,000 lx
3)
DIN/EN 60068-2-6, DIN/EN 60068-2-64
DIN/EN 60068-2-27
Storage: –40 °C ... +75 °C
1)
2)
Temperatures < –20 °C with 5 min warm up time.
Max. 95 % humidity, non-condensing.
Typ. value at +25 °C ambient temperature.
Dimensional drawing
(Dimensions in mm (inch))
64.6
(2.54)
Ø
(Ø
0.2
5 .5
2)
1
2
44.4
(1.75)
31.9
(1.26)
3
21
(0.83)
4
24.3
(0.96)
74.4
(2.93
)
5.8
(0.23)
13.8
(0.54)
22
(0.87)
6
5
6
2
(0.08)
42
(1.65)
① Reference
axis position measurement
② Mounting
holes, Ø 5.5 mm
③ Connector
M12, 5-pin
④ Ethernet M12
female connector, 4-pin
⑤ Status
LED [status]
⑥ T-slot
⑦ Adjustment
aid (slot)
2016-05-02 22:08:07 | Online data sheet
Subject to change without notice
24
(0.94)
69.4
(2.73)
7
DISTANCE SENSORS | SICK
3
OLM100-1005 | OLM100
LINEAR MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Connection type
OLM100-10x5 1 x socket M12, 4-pin 1 x connector M12, 5-pin
1
4
1
5
2
4
1
2
3
4
3
① RS-485
④ Ethernet
Connection diagram
OLM100-10x5 1 x socket M12, 4-pin 1 x connector M12, 5-pin
1
brn
wht
blu
blk
gra
4
1
2
3
4
5
L+
(+10 ... 30 V DC)
Data + *
M
(0 V)
Data – *
FE
(shield)
M12 (D-coded)
1 Tx+
2 Rx+
3 Tx–
4 Rx–
M12 (A-coded)
* Termination resistors
integrated in sensor
① RS-485
④ Ethernet
Recommended accessories
Other models and accessories
www.sick.com/OLM100
Brief description
Type
Part no.
Other mounting accessories
4 pieces, Sliding nut set, M5, 4x, Included in delivery
Sliding nuts
2017550
Plug connectors and cables
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: cable
Cable: Power, drag chain use, PUR, halogen-free, shielded, 5 m
Head A: male connector, M12, 4-pin, straight, D-coded
Head B: male connector, RJ45, 8-pin, straight
Cable: Ethernet, drag chain use, PUR, shielded, 2 m
Head A: male connector, M12, 4-pin, angled, D-coded
Head B: male connector, RJ45, 8-pin, straight
Cable: EtherNet/IP, PUR, halogen-free, shielded, 2 m
DOL-1205-G05MAC
6036384
SSL-2J04-G02ME
6034414
SSL-2J04-H02ME
6047911
4
DISTANCE SENSORS | SICK
Online data sheet | 2016-05-02 22:08:07
Subject to change without notice
LINEAR MEASUREMENT SENSORS
Brief description
Head A: male connector, M12, 5-pin, straight, A-coded
Cable: CANopen, DeviceNet, shielded
OLM100-1005 | OLM100
Type
STE-1205-GA
Part no.
6027533
2016-05-02 22:08:07 | Online data sheet
Subject to change without notice
DISTANCE SENSORS | SICK
5