RD6R1A
Rotary Type
Long-life sensor supporting absolute linearity
■
Typical Specifications
Items
Rated Voltage
Operating life
Total resistance
Operating temperature range
Specifications
5V DC
500,000 cycles
3.8kΩ
ー40℃ to +85℃
Product Line
Mounting method
Connector type
Linearity
guarantee range
310°
Linearity
±2%
Hollow shaft
variation
φ3.53
Minimum order unit(pcs.)
Japan
1,800
Export
1,800
Model No.
RD6R1A0008
Note
Please ask about linearity with variable ranges other than 320°
.
Resistive
Position Sensors
Packing Specifications
Tray
Number of packages(pcs.)
1 case /Japan
1,800
1 case /export packing
1,800
Export package
measurements(mm)
540×360×250
Dimensions
½状
Unit:mm
Circuit Diagram
#1
Ø
3.53
#3
#2
Y
2.9
Ø
5.5
3.5
0.7
2-R10
Ø
CCW
4
CW
Ø
15
.5
R8
3
5
15.5
X
34
25.5
17.5
15.9
7.6
X
24.4
7
1.7
1.5
1.
7
ho
3-0.64
1.4
2-1.05
2
1.08
8.6
#1
9.8
#2 #3
Ø
le
1.5
16
Y
4.4
1.9
R1.6
.6
R1
20
24
10.6
°
75
Refer to P.477 for product specifications.
470
Resistive Position Sensors / Product Specifications
Method for Regulating the Linearity
Model RDC40
Output voltage ratio(%)
Output voltage ratio
(%)
1. Reference taper 90%/13rotations
1. Reference taper :: 90%/13rotations
2. VA is measured output value
2. VA is measured output value
100
100
VA
VA
±1%
±1%
Model RDC80
Output voltage ratio(%)
1. Reference taper : 100% /
340˚
2. The center is in the configuration diagram condition
2T output
4T output
100
50
±3%
0
180˚(phase difference)
±3%
±165˚
±165˚
5
5
0
0
0
0
13 rotations
13 rotations
0˚
center
Model RDC50 / RDC90 / RD6R1A / RDCC0
1. Reference taper:100%/A
2. Index point is 50% output point(RDC50/RDC90/RDCC0)
The center is in the configuration diagram condition
100
Output voltage ratio(%)
C
Model RDC10 / RD7
With rated voltage applied between terminals 1 and 3, the straight line which
connects the measured output values VB and VA at specified reference positions
B and A is assumed to be an ideal straight line, so that deviation against the ideal
straight line when the voltage applied between terminals 1 and 3 is assumed to be
100% can be expressed as a percentage.
V
A
50
Resistive
Position Sensors
0
0˚
B
Position B
Position A
(Mecha stroke)
V
B
B
A
Series
A
333.3°
80°
260°
320°
30°
B
±
160°
±30°
±
122°
±
155°
±
15°
C
±2%
±3%
±2%
±2%
RDC50
RDC90
RD6R1A
RDCC0
Resistive Position Sensors / Measurement and Test Methods
Resistive Position Sensor
〔Total
Resistance〕
The total resistance, with the shaft(lever)placed at the end of terminal 1 or 3, shall be determined by
measuring the resistance between the resistor terminals 1 and 3 unless otherwise specified.
〔Rating Voltage〕
The rating voltage corresponding to the rated power shall be determined by the following equation. When the
resulting rated voltage exceeds the maximum operating voltage of a specific resistor, the maximum operating
voltage shall be taken as the rated voltage.
E=√ P・R
E:Rated voltage
(V)
P:Rated power W)
(
R:Total nominal resistance
Ω)
(
477
Resistive Position Sensors
List of Varieties
Type
Series
Rotary Type
Magnetic Rotary Type
RDC40
RDC50
RDC90
RDC80
RD6R1A
RDCC0
NEW
Photo
Direction of lever
Effective electrical angle(°
)
Linearity guarantee range(°
)
Horizontal
5,400
(15 rotations)
4,680
(13 rotations)
Vertical
Horizontal
333.3
320
80, 260
60, 244
Vertical
340
(1-phase)
360
(2-phase)
330
(1-phase)
360
(2-phase)
320
310
30
±
15
Travel
ー
ー
ー
ー
ー
ー
Operating temperature range
Operating life
Available for automotive use
Life cycle (availability)
Operating force
Rotational torque
Total resistance
tolerance
Electrical
performance
Linearity(%)
Rated voltage
(V DC)
Cold
Environmental
performance
Dry heat
Damp heat
Terminal style
Page
−30℃ to +80℃
100,000 cycles
●
1,000,000 cycles
●
−40℃ to +
120℃
10,000,000
cycles
●
100,000 cycles
●
−40℃ to +85℃
500,000 cycles
●
0℃ to +50℃
10,000,000
cycles
ー
Resistive
Position Sensors
Mechanical
performance
ー
1.96mN m max.
・
ー
2mN½m max.
±30%
ー
ー
10mN m max.
・
ー
100mN m
・
±20%
ー
5mN m max.
・
ー
±2
±
1
±2
±3
5
±2 (320°
)
−30℃ 240h
80℃ 240h
60℃,
90 to 95%RH 240h
Connector
−40℃ 168h
120℃ 168h
60℃, 90 to 95%RH 96h
Insertion / Reflow
466
Reflow
469
470
85℃ 168h
−40℃ 240h
85℃ 240h
80℃,
60℃,
90 to 95%RH 96h 90 to 95%RH 240h
Connector
471
Resistive Position Sensors Measurement and Test Methods ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 477
Resistive Position Sensors Soldering Conditions・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 478
Resistive Position Sensors Cautions ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 479
Note
●
Indicates applicability to all products in the series.
464
Resistive Position Sensors / Soldering Conditions
Reference for Manual Soldering
Series
RDC50, RDC90, RDC80
RDC10, RD7
Tip temperature
350±5℃
350℃ max.
Soldering time
3
+1
s
0
3s max.
Reference for Dip Soldering
Series
Preheating
Soldering surface
temperature
100 to 150℃
100℃ max.
Dip soldering
Soldering
temperature
260±5℃
260℃ max.
Heating time
1minute max.
1minute max.
Soldering time
10±
1s
5s max.
No. of solders
1 time
1 time
RDC501, RDC502
RD7
Example of Reflow Soldering Condition
1. Cleaning Cleaning should not be attempted.
2. Type of solder to be used Use cream solder that contains 10 to 15 %wt flux.
3. Number of solder applications - apply solder only once
4. Recommended reflow conditions
Resistive
Position Sensors
Temperature
(℃)
300
A
B
200
C
D
100
Room
temperature
Pre-heating
E max.
F max.
I max.
G max.
Time s)
(
H max.
Series
RDC503
RDC506
RDC90
RDC80
A
250℃
255℃
250℃
B
230℃
230℃
ー
C
180℃
ー
180℃
D
150℃
ー
150℃
E
2min.
ー
90±30s
F
ー
2min.
ー
G
5s
10s
10±
1s
H
40s
1min.
ー
I
4min.
4min.
ー
No. of
reflows
1 time
1 time
1 time
Notes
1. When using an infrared reflow oven, solder may not always be applied as intended.
Be sure to use a hot air reflow oven or a type that uses infrared rays in combination with hot air.
2. The temperatures given above are the maximum temperatures at the terminals of the sensor when employing a hot air
reflow method. The temperature of the PC board and the surface temperature of the sensor may vary greatly depending
on the PC board material, its size and thickness. Ensure that the surface temperature of the sensor does not rise to 250℃
or greater.
3. Conditions vary to some extent depending on the type of reflow bath used. Be sure to give due consideration to this prior to use.
478