MI2500RU
Series
Compact, 1 x 1 Inch
25W, 4:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
25W Output Power
•
4:1 Input Voltage Range
•
Compact 1 x 1 Inch Case
•
1,500 VDC Isolation
•
12 Standard Models
•
Efficiency to 90%
•
Wide Temp Operation
Input
Parameter
Input Start Voltage
Input Filter
Start-Up Time
Conditions
Min.
24 VDC Input
48 VDC Input
LC Filter
See Note 1
Conditions
Dual Output, Balanced Loads
V
IN
= Min to Max
Single Output
Dual Output
Asymmetrical Load 25%/100%
3.3 & 5.0 Vout Models
12, 15 & Dual Output Models
25% Load Step Change
250
±3.0
Min.
Typ.
Max.
9.0
18.0
30
Typ.
Max.
±1.0
±2.0
±0.2
±0.2
±1.0
±5.0
100
150
±5.0
±0.02
Units
VDC
mS
Units
%
%
%
%
%
mV P - P
µSec
%
%/°C
%
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
•
Industry Standard Pin-Out
Load Regulation, Min Load to Full Load
Cross Regulation, Dual Outputs
Ripple & Noise, See Note 2
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Power Protection
Output Short Circuit, See Note 4
150
Continuous (Autorecovery)
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Units
VDC
M
pF
kHz
Units
2,000
285
Environmental
Parameter
Conditions
MI2548S-03RU
MI2524S-15RU, MI2548S-05RU
MI2548S-12RU, MI2548S-15RU
MI2524S-03RU
MI2524S-05RU, MI2524S-12RU
MI2524D-12RU, MI2524D-15RU
MI2548D-12RU, MI2448D-15RU
Case
Min.
Max
No Hsink
Max.
Heatsink
+57
+56
-40
+53
+50
+65
+64
+61
+59
+105
+125
95
°C
°C
%
°C
Operating Temperature Range,
Ambient Without Heatsink
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
-50
Free Air Convection
RH, Non-condensing
See Mechanical Diagrams (Page 4)
Metal with Non-Conductive Base
0.58 Oz (16.5g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
315
Min.
-0.7
-0.7
Typ.
Max.
Units
kHours
Units
VDC
°C
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Typ.
Max.
50.0
100.0
260.0
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MI2524S-03RU
MI2524S-05RU
MI2524S-12RU
MI2524S-15RU
MI2524D-12RU
MI2524D-15RU
MI2548S-03RU
MI2548S-05RU
MI2548S-12RU
MI2548S-15RU
MI2548D-12RU
MI2548D-15RU
Voltage
(VDC)
Nominal
24
24
24
24
24
24
48
48
48
48
48
48
Range
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
Current
(mA)
Full-Load No-Load
950
1,170
1,175
1,160
1,170
1,180
470
580
580
580
585
590
85
85
85
85
85
85
45
45
45
45
45
45
Voltage
(VDC)
www.micropowerdirect.com
Output
Current
(mA, Max)
Current
(mA, Min)
Efficiency
(%, Typ)
Over
Fuse
Voltage Capacitive
Rating
Load
Protection
(µF Max)
Slow-Blow
(VDC)
(mA)
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±12.0
±15.0
6,000
5,000
2,090
1,670
±1,040
±840
6,000
5,000
2,090
1,670
±1,040
±840
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
87
89
89
90
89
89
88
90
90
90
89
89
3.9
6.2
15.0
18.0
±15.0
±18.0
3.9
6.2
15.0
18.0
±15.0
±18.0
10,300
6,800
1,200
750
±680
±380
10,300
6,800
1,200
750
±680
±380
5,000
5,000
5,000
5,000
5,000
5,000
2,500
2,500
2,500
2,500
2,500
2,500
Notes:
1. Start up time is measured at nominal input and with a constant resistive load.
2. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor
be connected in parallel from the +V
OUT
to the -V
OUT
pin for single output unis; or from each output to
common for dual output units..
3. Transient recovery is measured to within a 1% error band for a load step change of 25%.
4. Short circuit protection is provided by a “hiccup mode” circuit.
5. Operation at no-load will not damage these units.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model
Selection table above for the correct rating.
For heatsink option, add suffix “H” to model number (i.e.
MI2548S-05RU-H)
External Trim
MI25xxS-03RU
Trim Down
Vout
R
DOWN
Trim Up
Vout
R
UP
MI25xxS-05RU
Trim Down
Vout
R
DOWN
Trim Up
Vout
R
UP
V
O
x 1.01 V
O
x 1.02 V
O
x 1.03 V
O
x 1.04 V
O
x 1.05 V
O
x 1.06 V
O
x 1.07 V
O
x 1.08 V
O
x 1.09 V
O
x 1.10
106.87
47.76
28.06
18.21
12.30
8.36
5.55
3.44
1.79
0.48
Volts
k
V
O
x 0.99 V
O
x 0.98 V
O
x 0.97 V
O
x 0.96 V
O
x 0.95 V
O
x 0.94 V
O
x 0.93 V
O
x 0.92 V
O
x 0.91 V
O
x 0.90
138.88
62.41
36.92
24.18
16.53
11.44
7.79
5.06
2.94
1.24
Volts
k
V
O
x 1.01 V
O
x 1.02 V
O
x 1.03 V
O
x 1.04 V
O
x 1.05 V
O
x 1.06 V
O
x 1.07 V
O
x 1.08 V
O
x 1.09 V
O
x 1.10
60.84
27.40
16.25
10.68
7.34
5.11
3.51
2.32
1.39
0.65
Volts
k
V
O
x 0.99 V
O
x 0.98 V
O
x 0.97 V
O
x 0.96 V
O
x 0.95 V
O
x 0.94 V
O
x 0.93 V
O
x 0.92 V
O
x 0.91 V
O
x 0.90
72.61
32.55
19.20
12.52
8.51
5.84
3.94
2.51
1.39
0.50
Volts
k
MI25xxS-12RU
Trim Down
Vout
R
DOWN
Trim Up
Vout
R
UP
V
O
x 1.01 V
O
x 1.02 V
O
x 1.03 V
O
x 1.04 V
O
x 1.05 V
O
x 1.06 V
O
x 1.07 V
O
x 1.08 V
O
x 1.09 V
O
x 1.10
351.00
157.50
93.00
60.75
41.40
28.50
19.29
12.37
7.00
2.70
Volts
k
V
O
x 0.99 V
O
x 0.98 V
O
x 0.97 V
O
x 0.96 V
O
x 0.95 V
O
x 0.94 V
O
x 0.93 V
O
x 0.92 V
O
x 0.91 V
O
x 0.90
413.55
184.55
108.22
70.05
47.15
31.88
20.98
12.80
6.44
1.35
Volts
k
An external resister may be added to adjust the converter
output on single output units.
To adjust the output UP, connect a 5%, 3W resistor
between the minus output pin (5) and the Vout trim
pin (6). To adjust the output DOWN, connect a 5%, 3W
resistor between the plus output pin (4) and the Vout
trim pin (6).
The trim table at left gives suggested resistor values
for this adjustment.
MB25xxS-15RU
Trim Down
Vout
R
DOWN
Trim Up
Vout
R
UP
V
O
x 1.01 V
O
x 1.02 V
O
x 1.03 V
O
x 1.04 V
O
x 1.05 V
O
x 1.06 V
O
x 1.07 V
O
x 1.08 V
O
x 1.09 V
O
x 1.10
422.77
189.89
112.26
73.44
50.15
34.63
23.54
15.22
8.75
3.58
Volts
k
V
O
x 0.99 V
O
x 0.98 V
O
x 0.97 V
O
x 0.96 V
O
x 0.95 V
O
x 0.94 V
O
x 0.93 V
O
x 0.92 V
O
x 0.91 V
O
x 0.90
530.73
238.61
141.24
92.56
63.35
43.87
29.96
19.53
11.41
4.92
Volts
k
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
EMC Specifications
All units should meet EN 55022 (CE/RE) class A/B
with the simple external circuit shown; using the
component values given in the table.
To meet the requirements of EN 61000-4-4 and
EN 61000-4-5, the value of C
1
should be changed
to 220
µF/100V.
Contact the factory for more
information.
Standard
EN55022 Class A
EN55022 Class B
Model
MI2524x-xxRU
MI2548x-xxRU
MI2524x-xxRU
C
1
---
---
www.micropowerdirect.com
C
2
3.3 µF/50V 1210 MLCC
3.3 µF/100V 1210 MLCC
3.3 µF/50V 1210 MLCC
L
1
2.2
µH
4.7
µH
2.2
µH
4.7
µH
C
3
---
---
3.3 µF/50V 1210 MLCC
C
4
/ C
5
---
---
1,800 pF/2kV 1206 MLCC
3.3 µF/50V 1210 MLCC
MI2548x-xxRU
3.3 µF/100V 1210 MLCC 3.3 µF/100V 1210 MLCC
3.3 µF/100V 1210 MLCC 1,800 pF/2kV 1206 MLCC
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT, See Notes
Surge, See Notes
CS
Standard
EN 55022
Class A/B
EN 55022
Class A/B
EN 61000-4-2 Criteria A; ±8 kV Air, ±6 kV Contact
EN 61000-4-3
Criteria A; 10V/m
EN 61000-4-4
Criteria A; ±2 kV
EN 61000-4-5
Criteria A; ±1 kV
EN 61000-4-6
Criteria A; 10 V/rms
Derating Curves
MI2548S-03RU Without Heatsink
MI2548S-03RU With Heatsink
MI2524S-15RU, MI2548S-05RU, -12RU, -15RU Without Heatsink
MI2524S-15RU, MI2548S-05RU, -12RU, -15RU With Heatsink
MI2524S-03RU Without Heatsink
MI2524S-03RU With Heatsink
MI2524S-05RU, -12RU, MI25xxD-xxRU Without Heatsink
MI2524S-05RU, -12RU, MI25xxD-xxRU With Heatsink
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
Remote On/Off
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Control Input Current (ON)
Control Input Current (OFF)
www.micropowerdirect.com
Min
3.5
0.0
Typ
Max
12.0
1.2
Units
Applying a signal to pin 3 will turn the unit ON/OFF. If the
pin is left open, the unit operates. If grounded, the unit will
shut off. The specifications for the ON/OFF function are
given in the table at left.
VDC
VDC
3.0
mA
Referenced to Negative Input (pin 2)
0.5
mA
-0.5
mA
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
Single
+V
IN
-V
IN
+V
OUT
Trim
-V
OUT
Remote On/Off
Pin
1
2
3
4
5
6
Dual
+V
IN
-V
IN
+V
OUT
Common
-V
OUT
Remote On/Off
Mechanical Dimensions:
With Optional Heatsink
For the heatsink option, add suffix “H” to the
model number (i.e.
MI2524S-12RU-H)
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx = ±0.02 (±0.50)
•
Heatsink is black, anodized aluminum
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com