MHI100DI5.7
Series
High Isolation, 1W SIP
Single & Dual Output
DC/DC Converters
Electrical Specifications
Key Features:
•
1W Output Power
•
5.7 kV Isolation
•
15 kV/µS CMTI
•
40 Standard Models
•
Miniature SIP Case
•
-40°C to +85°C Operation
•
Low Cost
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Filter
Min.
5 VDC Input
4.5
12 VDC Input 10.8
15 VDC Input 13.5
24 VDC Input 21.6
Capacitor Filter
Min.
Typ.
5.0
12.0
15.0
24.0
Max.
5.5
13.2
16.5
26.4
Units
VDC
Output
Conditions
Typ.
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 2
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
Max.
±5.0
±1.0
Units
%
%
%
mV P - P
%/°C
•
Industry Standard Pin-Out
Parameter
Dual Output, Balanced Loads
±0.1
For V
IN
Change of 1%
±1.2
See Model Selection Guide
See Note 3
±0.01
Momentary (0.5 Sec Max)
Conditions
Rated For 60 Sec
Tested For 1 Sec
500 VDC
100 kHz, 1V
Min.
5,200
5,700
10
15
100
Conditions
Ambient
Case
Min.
-40
Typ.
+25
Typ.
100
±0.02
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Common Mode Transient Immunity
Switching Frequency
Max.
Units
VDC
G
pF
kV/µS
kHz
Max.
+85
+100
+125
95
Units
°C
°C
%
7
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
-55
Free Air Convection
RH, Non-condensing
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
See Mechanical Diagram (Page 3)
Non-Conductive Black Plastic (UL94-V0)
0.08 Oz (2.4g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
5 VDC Input
12 VDC Input
15 VDC Input
24 VDC Input
1.5 mm From Case for 10 Sec
Min.
2.0
Min.
Typ.
Max.
Units
MHours
Units
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Typ.
Max.
9.0
18.0
20.0
30.0
260
Input Voltage Surge (0.1 Sec)
VDC
Lead Temperature
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MHI105S-03DI5.7
MHI105S-05DI5.7
MHI105S-09DI5.7
MHI105S-12DI5.7
MHI105S-15DI5.7
MHI105D-05DI5.7
MHI105D-09DI5.7
MHI105D-12DI5.7
MHI105D-15DI5.7
MHI105D-1509DI5.7
MHI112S-03DI5.7
MHI112S-05DI5.7
MHI112S-09DI5.7
MHI112S-12DI5.7
MHI112S-15DI5.7
MHI112D-05DI5.7
MHI112D-09DI5.7
MHI112D-12DI5.7
MHI112D-15DI5.7
MHI112D-1509DI5.7
MHI115S-03DI5.7
MHI115S-05DI5.7
MHI115S-09DI5.7
MHI115S-12DI5.7
MHI115S-15DI5.7
MHI115D-05DI5.7
MHI115D-09DI5.7
MHI115D-12DI5.7
MHI115D-15DI5.7
MHI115D-1509DI5.7
MHI124S-03DI5.7
MHI124S-05DI5.7
MHI124S-09DI5.7
MHI124S-12DI5.7
MHI124S-15DI5.7
MHI124D-05DI5.7
MHI124D-09DI5.7
MHI124D-12DI5.7
MHI124D-15DI5.7
MHI124D-1509DI5.7
Voltage
(VDC)
Nominal
5
5
5
5
5
5
5
5
5
5
12
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
15
15
24
24
24
24
24
24
24
24
24
24
Range
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
Current
(mA)
www.micropowerdirect.com
Output
Current
(mA, Min)
Voltage Current
Full-Load No-Load
(VDC) (mA, Max)
286
35
3.3
303
286
35
5.0
200
266
35
9.0
111
261
35
12.0
84
254
35
15.0
66
282
35
±5.0
±100
269
35
±9.0
±56
262
35
±12.0
±42
254
35
±15.0
±33
+15.0
+33
260
35
-9.0
-55
117
17
3.3
303
117
17
5.0
200
110
17
9.0
111
108
17
12.0
84
104
17
15.0
66
116
17
±5.0
±100
111
17
±9.0
±56
108
17
±12.0
±42
104
17
±15.0
±33
+15.0
+33
107
17
-9.0
-55
95
16
3.3
303
95
16
5.0
200
89
16
9.0
111
90
16
12.0
84
84
16
15.0
66
94
16
±5.0
±100
90
16
±9.0
±56
86
16
±12.0
±42
84
16
±15.0
±33
+15.0
+33
87
16
-9.0
-55
60
12
3.3
303
60
12
5.0
200
56
12
9.0
111
53
12
12.0
84
52
12
15.0
66
59
12
±5.0
±100
56
12
±9.0
±56
55
12
±12.0
±42
53
12
±15.0
±33
+15.0
+33
55
12
-9.0
-55
Fuse
Load
Efficiency Regulation Capacitive
Rating
Load
(%, Typ)
Slow-Blow
(%, Max)
(µF, Max)
(mA)
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
±0.0
±0.0
70
70
75
77
78
71
75
77
78
76
71
71
76
78
79
72
75
78
79
77
70
70
75
75
79
71
75
78
79
76
70
70
75
78
80
71
75
77
78
75
±20.0
±15.0
±10.0
±10.0
±10.0
±15.0
±10.0
±10.0
±10.0
±10.0
±20.0
±15.0
±10.0
±10.0
±10.0
±15.0
±10.0
±10.0
±10.0
±10.0
±20.0
±15.0
±10.0
±10.0
±10.0
±15.0
±10.0
±10.0
±10.0
±10.0
±20.0
±15.0
±10.0
±10.0
±10.0
±15.0
±10.0
±10.0
±10.0
±10.0
1,000
470
470
220
220
220
220
100
100
100
220
1,000
470
470
220
220
220
220
100
100
100
220
1,000
470
470
220
220
220
220
100
100
100
220
1,000
470
470
220
220
220
220
100
100
100
220
500
500
500
500
500
500
500
500
500
500
500
250
250
250
250
250
250
250
250
250
250
250
200
200
200
200
200
200
200
200
200
200
200
150
150
150
150
150
150
150
150
150
150
150
Notes:
1. The specified maximum capacitive load is for each output.
2. Load regulation is measured over a range of 20% I
OUT
to 100% I
OUT
.
3. When measuring output ripple & noise, it is recommended that an external capacitor
(1
µF
typ.) be placed from the +V
OUT
to the -V
OUT
pins for single output units and from
each output to common for dual output models.
4. The converter should be connected to a low ac-impedance source. An input
source with a highly inductive impedance may affect the stability of the converter.
In applications where the converter output loading is high and input power is sup-
plied over long lines, it may be necessary to use a capacitor on the input to insure
start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a 2.2
µF
is recom-
mended; for 12V & 15V input units, a 1.0
µF;
and for 24V units a 0.47
µF.
5. Operation at no-load will not damage the unit, but they may not meet all specifica-
tions.
6. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection tables for the correct rating.
Derating Curve
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
IGBT Applications
www.micropowerdirect.com
Notes:
The
MHI100x-xxD
series is a good choice for IGBT
applications. They are designed to withstand the
extra stress caused by the high voltage switching
transients present in IGBT drive circuits.
The
MHI1xxD-1509DI5.7
models are specifi-
cally designed for use with “962” type drivers.
The
IGD962
(available from
MPD)
is a hybrid
integrated circuit specifically designed to drive
N-channel IGBT modules. It provides the I/O
isolation, high speed, drive voltage stability and
fault protection required to control most MOS
gated power devices.
The drawing at right illustrates a typical connec-
tion of the
MHI105D-1509DI5.7
to the
IGD962.
For more information on this connection, please
contact the factory.
Mechanical Dimensions
Pin Connections
Pin
1
2
5
6
7
Pin
1
2
5
6
7
Single Output
+V
IN
-V
IN
-V
OUT
No Pin
+V
OUT
Dual Output
+V
IN
-V
IN
-V
OUT
Common
+V
OUT
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com