2020-23T-C3FLF概述

Surge Protection Circuit, ROHS COMPLIANT PACKAGE-3

2020-23T-C3FLF规格参数

参数名称属性值
是否无铅不含铅
是否Rohs认证符合
零件包装代码MODULE
包装说明,
针数3
Reach Compliance Codecompli
JESD-30 代码X-XXSS-X3
JESD-609代码e3
湿度敏感等级1
功能数量1
端子数量3
最高工作温度90 °C
最低工作温度-40 °C
封装主体材料UNSPECIFIED
封装形状UNSPECIFIED
封装形式SPECIAL SHAPE
峰值回流温度(摄氏度)NOT SPECIFIED
表面贴装NO
电信集成电路类型SURGE PROTECTION CIRCUIT
温度等级INDUSTRIAL
端子面层TIN
端子形式UNSPECIFIED
端子位置UNSPECIFIED
处于峰值回流温度下的最长时间NOT SPECIFIED
Base Number Matches1

文档预览

下载PDF文档
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Fast acting
Balanced
Stable breakdown throughout life
Designed to operate with TBU devices
®
Applications
Telecommunications
Industrial electronics
Avionics
RoHS compliant* versions available
2020 T Series - 3-Pole Fast Gas Discharge Tube
Characteristics
Model No.
2020-15T
2020-23T
2020-42T
Characteristic
Minimum DC Sparkover
(100 V/s)
Throughout Service Life
60 V
500 V
180 V
650 V
360 V
850 V
Maximum Impulse Sparkover (5k V 1.2/50 µs)
Throughout Service Life
Impulse Transverse Delay...................1000 V/µs ............................................................................... < 75 ns
Insulation Resistance (IR) ...................50 V / 100 V ............................................................................ > 10
9
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................>1 A ........................................................................................ ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance .......................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage (Network Applied per ITU-T K.12)
2020-15T .......................................52 V ........................................................................................ < 150 ms
2020-23T .......................................80 V ........................................................................................ < 150 ms
2020-42T .......................................135 V ...................................................................................... < 150 ms
Service Life
1
.......................................8/20 µs, 5 kA .......................................................................... 1 operation
10/1000 µs, 1 kV, 100 A.......................................................... 100 operations
2
2/10 µs, 5 kV, 1000 A.............................................................. 10 operations
2
10/700 µs, 6 kV, 150 A............................................................ 50 operations
2
8/20 µs, 500 A, 1.2/50 µs, 500 V ............................................ 150 operations
2
600 V, 5 Arms, 0.2 sec. ........................................................... 10 operations
600 Vrms, 0.5 A - 60 A ........................................................... Fail-Short activates
3
230 Vrms, 0.5 A-25 A ............................................................. Fail-Short activates
3
Operating and Storage Temperature .................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) ....................................................................................................... 40 / 90 / 21
Notes:
1 Applied per conductor to center pin.
2 Surge polarity should be reversed between consecutive surges (+,-,+,-)
3 Applies only to GDT with optional Fail-Short. GDT operates and will survive with Fail-Short activation.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
Applications
Port Protection
CanBus
RS232
RS422
RS485
RS485
SDI
VDSL
GDT Device P/N
2020-23T
2020-23T
2020-23T
2020-23T
2020-42T
2020-23T
2020-15T
TBU
®
Device P/N
TBU-CA065-100-WH
TBU-CA065-200-WH
TBU-CA065-200-WH
TBU-CA065-200-WH
TBU-CA085-200-WH
TBU-CA065-100-WH
TBU-CA050-500-WH
“TBU” is a registered trademark of Bourns, Inc. in the U.S., Taiwan and European Community.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
无线病房呼叫系统硬件设计原理
  无线病房呼叫系统是由主机与从机两部分构成,在对其进行设计时,应根据其不同的侧重功能而有所不同。下面就对无线病房呼叫系统的主机与从机设计原理图做简单的介绍。   无线病房呼叫系统 ......
sairvee 医疗电子
印制电路板的一般分类:
印制板一般按用途、基材和结构来进行分类: 1、以用途分类民用印制板(消费类)-------电视机用印制板、音响设备用印制板、电子玩具用印制板、照像机用印制板等;工业用印制板(装备类)---- ......
pa2792 PCB设计
MSP430定时器 实现DAC????
如题, 1.如果PWM信号的占空比随时间变化,那么通过滤波之后的输出信号将是幅度变化的模拟信号。 2.由于PWM信号是数字信号,但是由于它的占空比是变化的,根据信号分析的原理知道该信号经过滤 ......
在路上的旁观者 微控制器 MCU
嵌入式流媒体服务器的设计与实现(太原理工硕士论文)
本帖最后由 paulhyde 于 2014-9-15 09:33 编辑 计算 机 网 络技术和多媒体技术的不断进步成为网络多媒体应用日益普及和发展的强大动力。人们在生产和生活中,也早已不满足单一的媒体形式,使得 ......
clark 电子竞赛
请问现在 的 wm 2003 ,WM5 , WM6 的智能系统 是不是都已经默认安装了 .NET 框架????
请问现在 的 wm 2003 ,WM5 , WM6 的智能系统 是不是都已经默认安装了 .NET 框架???? 是不是用 vb .net 开发的 智能系统应用程序放到 智能系统 就可以运行了...
shenzao 嵌入式系统
单片机读写多路U盘C程序1
/* CH375作为USB主机接口的程序示例,中断方式 */ /* MCS-51单片机C语言的示例程序, U盘数据读写 */ #include #include #include #ifndef TRUE #define TRUE 1 #define ......
TSB61 单片机

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1395  831  1295  1085  1423  29  17  27  22  49 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved