40W AC-DC High Reliability Slim Wall-mounted Adaptor
SGA40U
series
UL60950-1
IEC60950-1
■
Features
•
Ultra slim
•
Universal AC input / Full range
•
2 pole USA plug, Class
Ⅱ
power unit
•
No load power consumption <0.075W
•
Energy efficiency Level
Ⅵ
•
Comply with EISA 2007/DoE
•
Protections: Short circuit / Overload / Over voltage
•
Fully enclosed plastic case
•
Pass LPS
•
3 years warranty
■
Description
■
Applications
•
Consumer electronic devices
•
Telecommunication devices
•
Office facilities
•
Industrial equipments
SGA40U is a 40W ultra slim wall-mounted style single-output green adaptor series, which is compact and
convenient for carry. SGA40U is a class
Ⅱ
power unit (no FG) equipped with the standard 2-Pin U.S.
plug, accepting the input range from 90VAC to 264VAC. The whole series provides different models with
output voltages ranging between 5VDC and 48VDC that it can satisfy the demands for various types of
consumer electronic devices.
With the efficiency up to 89% and the extremely low no-load power consumption below 0.075W, SGA40U
is compliant with the latest U.S. energy regulation EISA 2007/DoE(Level
Ⅵ
). The supreme feature allows
the adaptor to save the energy when it is under either the operating mode or the standby mode. The entire
series is approved for international safety regulations; moreover, it adopts the 94V-0 flame retardant plastic
case that it can effectively prevent users from electric hazards.
■
Model Encoding
SGA 40 U 05 - P1J
P1J: Plug for standard model, 2.1
ψ×
5
.
5
ψ×
11mm,
DC plug type
C+ tuning fork type
Output voltage
US 2 pin AC plug
Rated wattage
Series name
Other options available by customer requested (see Page 4~5)
{
File Name:SGA40U-SPEC 2018-03-27
40W AC-DC High Reliability Slim Wall-mounted Adaptor
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
SGA40U05-P1J
SGA40U05
Note.2
5V
SGA40U
SGA40U18-P1J
SGA40U18
18V
2.22A
0 ~ 2.22A
40W
120mVp-p
±2.0%
±1.0%
±2.0%
SGA40U24-P1J
SGA40U24
24V
1.67A
0 ~ 1.67A
40W
150mVp-p
±2.0%
±1.0%
±2.0%
series
SGA40U09-P1J
SGA40U09
9V
4.44A
0 ~ 4.44A
40W
120mVp-p
±5.0%
±1.0%
±5.0%
SGA40U12-P1J
SGA40U12
12V
3.33A
0 ~ 3.33A
40W
120mVp-p
±3.0%
±1.0%
±3.0%
SGA40U15-P1J
SGA40U15
15V
2.66A
0 ~ 2.66A
40W
120mVp-p
±2.0%
±1.0%
±2.0%
SGA40U48-P1J
SGA40U48
48V
0.84A
0 ~ 0.84A
40W
150mVp-p
±2.0%
±1.0%
±2.0%
5A
0 ~ 5A
25W
RIPPLE & NOISE (max.)
Note.3
120mVp-p
VOLTAGE TOLERANCE
Note.4
±5.0%
LINE REGULATION
LOAD REGULATION
Note.5
±1.0%
Note.6
±5.0%
SETUP, RISE, HOLD UP TIME
500ms, 100ms, 12ms/230VAC
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
EMC
(Note. 8)
Note.7
90 ~ 264VAC
500ms, 100ms, 12ms/115VAC at full load
47 ~ 63Hz
84%
1A / 115VAC
0.25mA / 240VAC
110 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
-20 ~ +50
℃
(Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85
℃
, 10 ~ 95% RH non-condensing
±
0.03% /
℃
(0 ~ 40
℃
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2,
EAC TP TC 004
approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance
Standard
Parameter
to FCC PART15/CISPR22 Class B
87%
0.5A / 230VAC
70A / 230VAC
86.5%
86.5%
87%
88%
89%
Cold start 40A / 115VAC
Test Level / Note
Class B
Class B
Conducted emission
EMC EMISSION
Radiated emission
LIFE
OTHERS
MTBF
DIMENSION
PACKING
PLUG
CABLE
FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
3 years : 100% load 40
℃
, 12hours / day
400Khrs min. MIL-HDBK-217F(25
℃
)
75.5*32*47.5mm (L*W*H)
165g ; 60pcs / 13kg / CARTON
See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
CONNECTOR
1.All parameters are specified at 115VAC input, rated load, 25
℃
70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1
μ
f & 47
μ
f capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
NOTE
File Name:SGA40U-SPEC 2018-03-27
40W AC-DC High Reliability Slim Wall-mounted Adaptor
SGA40U
Pin Assignment
Output
PIN No.
+Vo
1
-Vo
2
3
-Vo
4
+Vo
Pin Assignment
Output
PIN No.
+Vo
1
-Vo
2
3
-Vo
4
+Vo
Pin Assignment
Output
PIN No.
series
Min. DIN 4 Pin with Lock (male)
2 3
1 4
KYCON
KPPX
-
4P equivalent
Type No.
R7B
Min. DIN 4 Pin with Lock (female)
Type No.
23
14
KYCON KPJX-CM-4S equivalent
R7BF
Stripped and tinned leads
L
Type No.
1
2
L1
Length of Land L1 by request
( MW’s standard length, L: 25 mm, L1: 10 mm)
1
(Ribbed or
White)
by customer
2
(Letter or
Black)
+Vo
-Vo
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:SGA40U-SPEC 2018-03-27