2. Specifications (Plug-in Standard type and TM type)
Characteristics
Arrangement
Contact
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Rating
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*
1
Insulation resistance (Initial)
Between open contacts
Breakdown voltage
Between contact sets
(Initial)
Between contact and coil
Temperature rise (coil) (at 70°C
158°F)
Operate time (at 20°C
68°F)*
2
Release time (at 20°C
68°F)*
2
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical (at nominal switching capacity)
Conditions for operation, transport and storage*
3
(Not freezing and condensing at low temperature)
Shock resistance
Mechanical
characteristics
Max. Operating speed
Unit weight
Item
1 Form C
Specifications
2 Form C
1 Form A (TM type)
Electrical
characteristics
Expected life
Conditions
Max. 100 mΩ
Max. 50 mΩ
Max. 100 mΩ
(By voltage drop 6 V DC 1A)
(By voltage drop 6 V DC 1A)
(By voltage drop 6 V DC 1A)
AgNi type
AgSnO
2
type
AgSnO
2
type
10A 250V AC, 10A 30V DC
5A 250V AC, 5A 30V DC
16A 250V AC, 16A 30V DC
4,000VA, 300W
1,250VA, 150W
4,000VA, 480W
250V AC, 30V DC
16A (at AC load),
5A
16A
10A (at DC load)
0.53W, 0.9VA
100mA 5V DC
1mA 1V DC
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
3,000 Vrms for 1min.
—
—
(Detection current: 10mA.)
5,000 Vrms for 1min. (Detection current: 10mA.)
Max. 60°C
140°F
(By resistive method, nominal coil voltage)
Max. 15ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 5ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without
diode)/Max. 20ms (with diode)
Min. 100 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 1.5 mm
AC: Min. 10
7
; DC: Min. 2×10
7
(at 300 times/min.)
Min. 10
5
(at 20 times/min.)
Min. 10
5
(at 10 times/min.)
Ambient temperature: –40°C to +70°C
–40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
10 times/min.
20 times/min. (at nominal switching capacity)
(at nominal switching capacity)
Approx. 19 g
.67 oz
Approx. 17 g
.60 oz
Approx. 19 g
.67 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB5E 201212-T
HN (AHN)
REFERENCE DATA
1-(1). Max. switching capacity
(1 Form C and 1 Form A)
1-(2). Max. switching capacity (2 Form C)
2-(1). Coil temperature rise (1 Form C/AC and
1 Form A/AC types)
Measured portion: Inside the coil
Ambient temperature: 70°C
158°F
100
50
30
20
16
10
5
1 Form C type
DC resistive load
1
0.5
20
0
1 Form A type DC resistive load
1 Form A and
1 Form C types
AC resistive load
10
Temperature rise,
°C
5
Contact current, A
120
100
80
60
40
Contact current, A
16A
0A
1
0.5
0.4
0.3
0.2 DC resistive load
AC resistive load
10
20 30 50
100
250
10
Contact voltage, V
20 30 50
100
250
Contact voltage, V
80
90 100 110 120 130 140
Coil applied voltage, %V
2-(2). Coil temperature rise (1 Form C/DC and
1 Form A/DC types)
Measured portion: Inside the coil
Ambient temperature: 70°C
158°F
70
Temperature rise,
°C
2-(3). Coil temperature rise (2 Form C/AC type)
Measured portion: Inside the coil
Ambient temperature: 70°C
158°F
2-(4). Coil temperature rise (2 Form C/DC type)
Measured portion: Inside the coil
Ambient temperature: 70°C
158°F
120
Temperature rise,
°C
100
80
60
40
20
0
Temperature rise,
°C
70
60
50
40
30
20
10
0
5A
0A
60
50
40
0A
30
20
10
0
16A
5A
0A
80
90 100 110 120 130 140
Coil applied voltage, %V
80
90 100 110 120 130 140
Coil applied voltage, %V
80
90 100 110 120 130 140
Coil applied voltage, %V
DIMENSIONS
(mm
inch)
1. Plug-in type 1 Form C