Halogen and Antimony Free. “Green” Device (Note 3)
SOT553
3. OUTPUT
2. GND
1. V
DD
SIP-3 (Bulk Pack)
Applications
Doors, Lids, Covers and Trays Position Detect Switches
Display Switch for Portable PCs and Tablets
On/Off Switch for PDAs and Digital Cameras
Liquid Level Detection for Coffee Machines
Smart Meters
Position, Proximity and Level Detection Contact-Less Switch in
Battery Powered Consumer, Home Appliances and Industrial
Applications
Notes:
1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS), 2011/65/EU (RoHS 2) & 2015/863/EU (RoHS 3) compliant.
2. See https://www.diodes.com/quality/lead-free/ for more information about Diodes Incorporated‘s definitions of Halogen- and Antimony-free, "Green" and
Lead-free.
3. Halogen- and Antimony-free "Green‖ products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may
be affected by exposure to absolute maximum rating conditions for extended periods of time.
7. The absolute maximum V
DD
of 7V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to
operate the device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions
(@T
A
= +25° unless otherwise specified.)
C,
Symbol
V
DD
V
OUT_MAX
T
A
Characteristic
Supply Voltage
Maximum Output Pin Voltage
Operating Temperature Range
Operating
Operating
Operating
Conditions
Rating
2.5 to 5.5
5.5
-40 to +85
Unit
V
V
°
C
Electrical Characteristics
Symbol
V
OUT_ON
I
OFF
Output On Voltage
(@T
A
= +25° V
DD
= 3V, unless otherwise specified.)
C,
Conditions
I
OUT
= 1mA
V
OUT
= 5.5V, Output off
During ‗awake‘ period,
T
A
= +25° V
DD
= 3V
C,
During ‗awake‘ period,
T
A
= -40° to +85° V
DD
= 2.5V to 5.5V
C
C,
During ‗sleep‘ period,
T
A
= +25° V
DD
= 3V
C,
During ‗sleep‘ period,
T
A
= -40° to +85° V
DD
= 2.5V to 5.5V
C
C,
Min
—
—
—
—
—
—
—
—
—
—
—
—
Typ
0.1
<
0.1
3
3
5
—
8
—
75
75
0.1
Max
0.3
1
6
12
10
28
16
40
125
125
—
Unit
V
µA
mA
mA
µA
µA
µA
µA
µs
ms
%
Characteristic
Output Leakage Current
I
DD
(awake)
Supply Current
I
DD
(sleep)
I
DD
(sleep)
I
DD
(avg)
t
AWAKE
t
PERIOD
D.C.
Note:
Average Supply Current
Awake Time
Period
Duty Cycle
T
A
= +25° V
DD
= 3V
C,
T
A
= -40° to +85° V
DD
= 2.5V to 5.5V
C
C,
(Note 8)
(Note 8)
8. When power is initially turned on, the operating V
DD
must be within its correct operating range (2.5V to 5.5V) to guarantee the output sampling.
The output state is valid after the second operating cycle (typical 150ms).