SmartPro 3kVA Line Interactive Sine Wave UPS,
SNMPWEBCARD option, Tower, USB, Serial, EPO,
120V
MODEL NUMBER:
SMART3000SLT
Highlights
3kVA / 3000VA line interactive
tower UPS; Sine wave output
120V nominal output during
brownouts to 83 and
overvoltages to 145V
USB, RS232, EPO and optional
SNMP/Web card are available
for simultaneous use
Front panel status LEDs with
detailed load and battery
capacity display
NEMA L5-30P input; 6 NEMA
5-15/20R & 1 L5-30R outlets
Package Includes
SMART3000SLT UPS System
PowerAlert Software and cabling
Owner's manual
Description
3000VA line-interactive tower UPS system for server, networking and telecommunications equipment. Upright tower form factor. Offers sine wave 120V
nominal output in both AC and battery modes. Switches to battery-derived AC output during power failures and extreme voltage variations. Line-interactive
automatic voltage regulation (AVR) provides voltage boost/cut during brownouts/overvoltages to maintain regulated 120V nominal output over an input voltage
range of 83-145V. Includes NEMA L5-30P input plug and 7 UPS-supported output receptacles (6 x 5-15/20R, 1 x L5-30R). Network-grade AC surge and noise
suppression. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant
USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed
monitoring of equipment load levels, self-test data and utility power conditions via all three network interfaces. Includes PowerAlert power management
software and complete cabling. Three-stage metered current monitoring and battery charge status LEDs. Utility power and voltage regulation, and battery
warning LEDs. Audible alarm. Self-test. Field-replaceable, hot-swappable internal batteries. Attractive all-black color scheme.
Features
SmartPro line-interactive UPS system is ideal for voice, data, medical and industrial networking applications
Line-interactive voltage regulation maintains selectable 120V nominal output during brownouts as low as 83V and overvoltages to 145V
Enables continuous operation through blackouts, voltage fluctuations and surges
Line-interactive automatic voltage regulation (AVR) provides 12% and 24% voltage boost during brownouts and a 12% voltage cut during overvoltages
Standard internal battery set offers 9 min. runtime at half load (1125W) and 3.5 min. at full load (2250W)
Space-saving upright tower format
Network interfaces support simultaneous communications via built-in USB port, DB9 serial port and SNMPWEBCARD slot
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert power management software supports safe unattended shutdown, monitoring and control via local connected servers, plus any
number of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery
capacity, timed inverter shutoff, activate self-test and output power control
NEMA L5-30P input plug/6 x NEMA 5-15/20R and 1 x NEMA L5-30R output receptacles
1/5
Front panel LEDs provide current monitoring, voltage regulation, battery charge level and battery warning information
UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA capacity (kVA)
Output Watt Capacity (watts)
Output kW capacity
Output power factor
Nominal Output Voltage(s)
Supported
Frequency compatibility
Output voltage regulation (line mode)
Output voltage regulation (Battery
mode)
Built-in UPS output receptacles
Output circuit breaker
Output AC waveform (AC mode)
Output AC waveform (battery mode)
3000
3
2250
2.2
0.8
120V
60 Hz
-18% / +8%
+/- 5%
6 5-15/20R outlet(s); 1 L5-30R outlet(s)
20A branch rated (x2) - each breaker protects 3 5-15/20R outlets, L5-30R is unbreakered
Sine wave
Pure Sine wave
INPUT
Rated input current (at maximum
load)
Nominal Input Voltage(s) Supported
UPS input connection type
Input circuit breaker
UPS Input cord length (ft.)
UPS Input cord length (m)
Recommended Electrical Service
Phase
20A
120V AC
L5-30P
30A
10
3
30A 120V
Single-Phase
BATTERY
Full load runtime (minutes)
Half load runtime (minutes)
DC system voltage (VDC)
3.5 min. (2250w)
9 min. (1125w)
48
2/5
Battery recharge rate (included
batteries)
Replacement battery cartridge
(internal UPS battery replacement)
Battery Access
Battery replacement description
Less than 4.5 hours from 10% to 90%
RBC54
Battery access door
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description
Overvoltage correction
Undervoltage correction
Severe undervoltage correction
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Input voltages between 127 and 145 are reduced by 12%
Input voltages between 96 and 108V are boosted by 12%
Input voltages between 83 and 95V are boosted by 24%
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for
load and battery charge level
Audible alarm indicates power failure and overload conditions
Power-fail alarm can be silenced using alarm-cancel switch
2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating
UPS AC suppression response time
EMI / RFI AC noise suppression
570
Instantaneous
Yes
PHYSICAL
Installation form factors supported
with included accessories
Primary form factor
UPS / Power Module dimensions in
primary form factor (height x width x
depth / inches)
UPS / Power Module dimensions in
primary form factor (height x width x
depth / cm)
UPS / Power Module weight (lbs)
UPS / Power Module weight (kg)
UPS Shipping dimensions (height x
width x depth / inches)
UPS Shipping dimensions (height x
width x depth / cm)
Tower
Tower
10.5 x 8.9 x 12.5
26.7 x 22.5 x 31.8
57
25.9
14.5 x 13.8 x 18
36.8 x 34.9 x 45.7
3/5
Shipping weight (kg)
Cooling method
UPS housing material
0
Fan
Steel
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC mode BTU / hr. (full load)
Battery mode BTU / hr. (full load)
AC mode efficiency rating (100%
load)
Audible Noise
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
318.8
1245.3
96%
Audible Noise < 50 dBA at Front Side 1 Meter
COMMUNICATIONS
Communications interface
Network monitoring port description
PowerAlert software
Communications cable
WatchDog compatibility
USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Supports detailed monitoring of UPS and site power conditions
Included
USB and DB9 cabling included
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
Low voltage transfer to battery
power (setpoint)
High voltage transfer to battery
power (setpoint)
2-4 milliseconds
83
145
SPECIAL FEATURES
Cold Start (startup in battery mode
during a power failure)
High availability UPS features
Green & high efficiency features
Cold-start operation supported
Hot swappable batteries
Greater than 95% efficiency - GREEN UPS
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty Period (Worldwide)
2-year warranty, 3 year with registration. Note:
Registration is required
for 3-year warranty.
4/5
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000
Ultimate Lifetime Insurance
Related Items
Optional Products
Model Number
DCATV
DNET1
DTEL2
ENVIROSENSE
PDUNV
PDU1215
SNMPWEBCARD
U022-010
WATCHDOGSW
WEXT5-2200-3000
Description
Network Surge Suppressor - Essential protection for TV/VCR coaxial lines
Network Surge Suppressor - Essential protection for data and communication lines
Network Surge Suppressor - Essential protection for data and communication lines
Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD or switched
PDU.)
Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical networking
equipment
Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical networking
equipment
For remote monitoring and control via SNMP, Web, or Telnet.
10-ft. USB2.0 A/B Gold Device Cable
(A Male to B Male)
WatchDog Service Monitoring / Reboot Software
5-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack models,
2200-3000VA or less
Qty.
1
1
1
1
1
1
1
1
1
1
More information, including related products, owner's manuals, and additional technical specifications, can be found online at:
http://www.tripplite.com/sku/SMART3000SLT.
© 2014 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
5/5