GBU601
THRU
GBU607
SINGLE PHASE 6.0 AMP BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
6.0 Amperes
GBU
.880(22.3)
.860(21.8)
.161(4.1)
.134(3.4)
FEATURES
* Ideal for printed circuit board
* Low forward voltage
* Low leakage current
* Polarity: marked on body
* Mounting position: Any
.100(2.54)
.085(2.16)
.047(1.2)
.035(0.9)
.139(3.5)
.133(3.4)
.232(5.9)
.213(5.4)
.073(1.85)
.057(1.45)
.752(19.1)
.720(18.3)
+
.720(18.29)
.680(17.27)
.024(0.6)
.016(0.4)
.106(2.7)
.091(2.3)
AC
.210(5.33)
SPACING
.190(4.83)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Tc=100 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 3.0A D.C.
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Operating Temperature Range, T
J
Storage Temperature Range, T
STG
Ta=100 C
GBU601 GBU602 GBU603 GBU604 GBU605 GBU606 GBU607
UNITS
50
35
50
100
70
100
200
140
200
400
280
400
6.0
175
1.1
5.0
500
-65 +150
-65 +150
600
420
600
800
560
800
1000
700
1000
V
V
V
A
A
V
A
A
C
C
288
RATING AND CHARACTERISTIC CURVES (GBU601 THRU GBU607)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
AVERAGE FORWARD CURRENT,(A)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
PEAK FORWARD SURGE CURRENT,(A)
9
8
7
6
5
4
3
2
1
0
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
250
200
175
150
Tj=25 C
8.3ms Single Half
Sine Wave
JEDEC method
100
50
0
1
5
10
NUMBER OF CYCLES AT 60Hz
0
20
40
60
80
100
120 140
160
CASE TEMPERATURE,( C)
50
100
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
50
INSTANTANEOUS FORWARD CURRENT,(A)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
50
3.0
1.0
Tj=25 C
Pulse Width 300us
1% Duty Cycle
REVERSE LEAKAGE CURRENT, ( A)
10
10
3.0
1.0
Tj=100 C
0.1
0.1
Tj=25 C
.01
0
.2
.4
.6
.8
1.0
1.2
1.4
.01
0
20
40
60
80
100 120 140
FORWARD VOLT
AGE,(V)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
289