SP339E
RS-232/RS-485/RS-422 TRANSCEIVER WITH INTERNAL TERMINATION
DECEMBER 2013
REV. 1.0.4
GENERAL DESCRIPTION
The SP339 is an advanced multiprotocol transceiver
supporting RS-232, RS-485, and RS-422 serial
standards in a 40 pin QFN package. Integrated cable
termination and four configuration modes allow all
three protocols to be used interchangeably over a
single cable or connector with no additional switching
components. Full operation requires only four
external charge pump capacitors.
The RS-485/422 modes feature one driver and one
receiver (1TX/1RX) in both half and full duplex
configurations. The RS-232 mode (3TX/5RX)
provides full support of all eight signals commonly
used with the DB9 RS-232 connector. A dedicated
diagnostic loopback mode is also provided.
The high speed drivers operate up to 20Mbps in RS-
485/422 modes, and up to 1Mbps in RS-232 mode.
All drivers can be slew limited to 250kbps in any
mode to minimize electromagnetic interference (EMI).
All transmitter outputs and receiver inputs feature
robust electrostatic discharge (ESD) protection to
±15kV IEC-61000-4-2 Air Gap, ±8kV IEC-61000-4-2
Contact, and ±15kV Human Body Model (HBM).
Each receiver output has full fail-safe protection to
avoid system lockup, oscillation, or indeterminate
states by defaulting to logic-high output level when
the inputs are open, shorted, or terminated but
undriven. No external biasing resistors are required.
The RS-232 receiver inputs include a 5k pull-down
to ground. The RS-485/422 receiver inputs are high
impedance (>96k when termination is disabled),
allowing up to 256 devices on a single communication
bus (1/8th unit load).
The SP339 operates from a single power supply,
either 3.3V or 5V, with low idle current (2mA typical in
all modes). The shutdown mode consumes less than
10µA for low power standby operation.
FEATURES
Pin selectable Cable Termination
No external resistors required for RS-485/422
termination and biasing
3.3V or 5V Single Supply Operation
Robust ESD Protection on bus pins
■
■
■
±15kV IEC 61000-4-2 (Air Gap)
± 8kV IEC 61000-4-2 (Contact)
±15kV Human Body Model (HBM)
Max Data Rate of 20Mbps in RS-485/422 Modes
and up to 1Mbps in RS-232 Modes
Pin selectable 250kbps Slew Limiting
3 Drivers, 5 Receivers RS-232/V.28
1 Driver, 1 Receiver RS-485/422
■
■
Full and Half Duplex Configuration
1/8th Unit Load, up to 256 receivers on bus
RS-485/422 Enhanced Failsafe for open, shorted,
or terminated but idle inputs
Space saving 6mm x 6mm QFN-40 Package
Pin compatible with SP338E
TYPICAL APPLICATIONS
Dual Protocol Serial Ports (RS-232 or RS-485/422)
Industrial Computers
Industrial and Process Control Equipment
Point-Of-Sale Equipment
Networking Equipment
HVAC Controls Equipment
Building Security and Automation Equipment
ORDERING INFORMATION
P
ART
N
UMBER
SP339EER1-L
SP339EER1-L/TR
SP339ECR1-L
SP339ECR1-L/TR
P
ACKAGE
40-pin QFN
40-pin QFN
40-pin QFN
40-pin QFN
O
PERATING
T
EMPERATURE
R
ANGE
-40°C to +85°C
-40°C to +85°C
0°C to +70°C
0°C to +70°C
D
EVICE
S
TATUS
Active
Active
Active
Active
N
OTE
:
-L = Green / RoHS Compliant, /TR = Tape and Reel
Exar
Corporation 48720 Kato Road, Fremont CA, 94538
•
(510) 668-7000
•
FAX (510) 668-7017
•
www.exar.com
SP339E
RS-232/RS-485/RS-422 TRANSCEIVER WITH INTERNAL TERMINATION
REV. 1.0.4
ABSOLUTE MAXIMUM RATINGS
These are stress ratings only and functional operation of the device at these ratings or any other above those indicated in
the operation sections to the specifications below is not implied. Exposure to absolute maximum rating conditions for
extended periods of time may affect reliability and cause permanent damage to the device.
Supply Voltage V
CC
Receiver Input Voltage (from Ground)
Driver Output Voltage (from Ground)
Short Circuit Duration, TX out to Ground
Voltage at TTL Input Pins
Storage Temperature Range
Lead Temperature (soldering, 10s)
Power Dissipation 40-pin QFN
(derate 17mW/°C above +70°C)
-0.3V to +6.0V
±18V
±18V
Continuous
-0.3V to (V
CC
+ 0.5V)
-65°C to +150°C
+300°C
500mW
CAUTION:
ESD (ElectroStatic Discharge) sensitive device. Permanent damage may occur on unconnected devices subject to high
energy electrostatic fields. Unused devices must be stored in conductive foam or shunts. Personnel should be properly
grounded prior to handling this device. The protective foam should be discharged to the destination socket before devices
are removed.
ESD PROTECTION
M
IN
.
T
YP
.
±15
R1-R9
Tx Output & Rx Input Pins
±8
±15
All Other Pins
±4
M
AX
.
U
NITS
kV
kV
kV
kV
Human Body Model (HBM)
IEC 61000-4-2 (Contact)
IEC 61000-4-2 (Air Gap)
Human Body Model (HBM)
2