CMLT8099
w w w. c e n t r a l s e m i . c o m
SURFACE MOUNT SILICON
DUAL NPN TRANSISTOR
DESCRIPTION:
The CENTRAL SEMICONDUCTOR CMLT8099
consists of two individual, isolated 8099 NPN silicon
transistors, manufactured by the epitaxial planar
process and epoxy molded in an SOT-563 surface
mount package. This device has been designed for
small signal general purpose amplifier applications.
MARKING CODE: C89
SOT-563 CASE
APPLICATIONS:
• Small signal general purpose amplifiers
MAXIMUM RATINGS:
(TA=25°C)
Collector-Base Voltage
Collector-Emitter Voltage
Emitter-Base Voltage
Continous Collector Current
Power Dissipation
Operating and Storage Junction Temperature
Thermal Resistance
FEATURES:
• Device is
Halogen Free
by design
• Current IC=500mA
• Voltage VCEO=80V
SYMBOL
VCBO
VCEO
VEBO
IC
PD
TJ, Tstg
Θ
JA
80
80
6.0
500
350
-65 to +150
357
UNITS
V
V
V
mA
mW
°C
°C/W
ELECTRICAL CHARACTERISTICS PER TRANSISTOR:
(TA=25°C unless otherwise noted)
SYMBOL
TEST CONDITIONS
MIN
MAX
ICBO
VCB=80V
0.1
IEBO
VBE=6.0V
0.1
BVCBO
BVCEO
BVEBO
VCE(SAT)
VCE(SAT)
VBE(ON)
hFE
hFE
hFE
fT
Cob
Cib
IC=100μA
IC=10mA
IE=10μA
IC=100mA, IB=5.0mA
IC=100mA, IB=10mA
VCE=5.0V,
VCE=5.0V,
IC=10mA
IC=1.0mA
0.6
100
100
75
150
6.0
25
80
80
6.0
0.4
0.3
0.8
300
UNITS
μA
μA
V
V
V
V
V
V
VCE=5.0V, IC=10mA
VCE=5.0V, IC=100mA
VCE=5.0V, IC=10mA, f=100MHz
VCB=10V, IE=0, f=1.0MHz
VBE=0.5V, IC=0, f=1.0MHz
MHz
pF
pF
R3 (29-June 2015)
CMLT8099
SURFACE MOUNT SILICON
DUAL NPN TRANSISTOR
SERVICES
• Bonded Inventory
• Custom Electrical Screening
• Custom Electrical Characteristic Curves
• SPICE Models
• Custom Packaging
• Package Base Options
• Custom Device Development / Multi Discrete Modules (MDM™)
• Bare Die Available for Hybrid Applications
LIMITATIONS AND DAMAGES DISCLAIMER:
In no event shall Central be liable for any collateral, indirect,
punitive, incidental, consequential, or exemplary damages in connection with or arising out of a purchase order
or contract or the use of products provided hereunder, regardless of whether Central has been advised of
the possibility of such damages. Excluded damages shall include, but not be restricted to: cost of removal or
reinstallation, rework, ancillary costs to the procurement of substitute products, loss of profits, loss of savings, loss
of use, loss of data, or business interruption. No claim, suit, or action shall be brought against Central more than
two (2) years after the related cause of action has occurred.
In no event shall Central’s aggregate liability from any warranty, indemnity, or other obligation arising out of or in
connection with a purchase order or contract, or any use of any Central product provided hereunder, exceed the
total amount paid to Central for the specific products sold under a purchase order or contract with respect to which
losses or damages are claimed. The existence of more than one (1) claim against the specific products sold to
Buyer under a purchase order or contract shall not enlarge or extend this limit.
Buyer understands and agrees that the foregoing liability limitations are essential elements of a purchase order
or contract and that in the absence of such limitations, the material and economic terms of the purchase order or
contract would be substantially different.
R3 (29-June 2015)
w w w. c e n t r a l s e m i . c o m