VER :
A_2
update :
2015.03.05
AC-DC Switching Power Supply
SZA60U SERIES
KEY FEATURES
U Bracket Switching Power Supply
Universal Input: 90-264 VAC
Single Output
<0.3W No Load Input Power
5 VDC to 48 VDC Output
3000 VAC Input to Output Isolation
Ultra Compact Size: 3.15 x 2.35 x 1.5 Inches
3-Year Product Warranty
60 Watts
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Max Output Wattage (W)
Voltage
Frequency (Hz)
Input
Current (Full load)
Inrush Current (Cold Start)
Leakage Current
No Load Input Power (<230 VAC)
Voltage (V.DC.)
Voltage Accuracy
Current (mA) max
Line Regulation (LL-HL) (typ.)
Load Regulation (5-100%) (typ.)
Output
Maximum Capacitive Load (at 230 VAC)
Ripple
Noise
Efficiency (at 230V)
Trim
Hold-up Time (>115 VAC)
Over Power Protection
Protection
Over Voltage Protection
Short Circuit Protection
Input-Output
Isolation
Input-FG
Output-FG
(V.AC)
.(V.AC)
(Note.3)
SZA60U-5S
50W
47-63 Hz
2 A max. (115 VAC) / 1 A max. (230 VAC)
35 A max. (115 VAC) / 70 A max. (230 VAC)
0.75 mA max.
<0.3W
5V
±2%
10,000
±1%
±1%
10,000 uF
5,000 uF
4,000 uF
2,000 uF
1,000 uF
<0.2% Vout +40mV max (Vp-p)
<0.5% Vout +50mV max (Vp-p)
81%
±5%
10 ms min.
Auto recovery
Zener diode clamp
Auto recovery
3000VAC or 4242VDC
1500V
500V
-30°C…+70°C (with derating)
-50°C…+85°C
±0.02%/°C
95% RH
>130,000 h @ 25°C (MIL-HDBK-217F)
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
3.15 x 2.35 x 1.5 Inches
220 g
Free air convection
CE, UL60950
EN 55022 Class B
EN 55024
( 80.0 x 59.7 x 38.0 mm ) Tolerance
0.5
mm
87%
87%
88%
88%
5,000
4,000
2,500
1,250
12V
15V
24V
48V
SZA60U-12S
60W
SZA60U-15S
SZA60U-24S
SZA60U-48S
90-264 VAC or 120-370 VDC
Operating Temperature
Storage Temperature
Environment
Temperature coefficient
Humidity
MTBF
Vibration
Dimension (L x W x H)
Physical
Safety
EMC
Weight
Cooling Method
Agency Approvals
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER :
A_2
update :
2015.03.05
AC-DC Switching Power Supply
SZA60U SERIES
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. It's necessary 10R / 15φ thermistor at L input side in series connection.
3. Strongly recommend to conduct this test with DC Voltage. If customer wishes to test with AC Voltage,
please disconnect all Y-Capacitors within Arch power supply.
60 Watts
MECHANICAL DIMENSION
( Top View )
PIN#
1
2
3
4
5
Single
AC IN (N)
AC IN (L)
FG
+DC OUT
-DC OUT
DERATING
BLOCK DIAGRAMG
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-