Si2312CDS-T1-GE3 (Lead (Pb)-free and Halogen-free)
S
N-Channel
MOSFET
ABSOLUTE MAXIMUM RATINGS
T
A
= 25 °C, unless otherwise noted
Parameter
Drain-Source Voltage
Gate-Source Voltage
T
C
= 25 °C
T
C
= 70 °C
T
A
= 25 °C
T
A
= 70 °C
Pulsed Drain Current
Continuous Source-Drain Diode Current
T
C
= 25 °C
T
A
= 25 °C
T
C
= 25 °C
T
C
= 70 °C
T
A
= 25 °C
I
DM
I
S
Symbol
V
DS
V
GS
Limit
20
±8
6
a
5.1
5
b, c
4
b, c
20
1.75
1.04
b, c
2.1
1.3
1.25
b, c
0.8
b, c
- 55 to 150
260
A
Unit
V
Continuous Drain Current (T
J
= 150 °C)
I
D
Maximum Power Dissipation
P
D
W
T
A
= 70 °C
Operating Junction and Storage Temperature Range
Soldering Recommendations (Peak Temperature)
T
J
, T
stg
°C
THERMAL RESISTANCE RATINGS
Parameter
Maximum Junction-to-Ambient
b, d
Maximum Junction-to-Foot (Drain)
t
≤
5s
Steady State
Symbol
R
thJA
R
thJF
Typical
80
40
Maximum
100
60
Unit
°C/W
Notes:
a. Package limited
b. Surface Mounted on 1" x 1" FR4 board.
c. t = 5 s.
d. Maximum under steady state conditions is 125 °C/W.
e. Based on T
C
= 25 °C.
Document Number: 65900
S10-0641-Rev. A, 22-Mar-10
www.vishay.com
1
New Product
Si2312CDS
Vishay Siliconix
SPECIFICATIONS
T
J
= 25 °C, unless otherwise noted
Parameter
Static
Drain-Source Breakdown Voltage
V
DS
Temperature Coefficient
V
GS(th)
Temperature Coefficient
Gate-Source Threshold Voltage
Gate-Source Leakage
Zero Gate Voltage Drain Current
On-State Drain Current
a
Drain-Source On-State Resistance
a
Forward Transconductance
a
Dynamic
b
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Total Gate Charge
Gate-Source Charge
Gate-Drain Charge
Gate Resistance
Turn-On Delay Time
Rise Time
Turn-Off Delay Time
Fall Time
Turn-On Delay Time
Rise Time
Turn-Off Delay Time
Fall Time
Drain-Source Body Diode Characteristics
Continuous Source-Drain Diode Current
Pulse Diode Forward Current
Body Diode Voltage
Body Diode Reverse Recovery Time
Body Diode Reverse Recovery Charge
Reverse Recovery Fall Time
Reverse Recovery Rise Time
I
S
I
SM
V
SD
t
rr
Q
rr
t
a
t
b
I
F
= 4 A, dI/dt = 100 A/µs, T
J
= 25 °C
I
S
= 4 A, V
GS
=
0 V
0.75
12
5
7
5
T
C
= 25 °C
1.75
20
1.2
20
10
A
V
ns
nC
ns
C
iss
C
oss
C
rss
Q
g
Q
gs
Q
gd
R
g
t
d(on)
t
r
t
d(off)
t
f
t
d(on)
t
r
t
d(off)
t
f
V
DD
= 10 V, R
L
= 2.2
Ω
I
D
≅
4 A, V
GEN
= 5 V, R
g
= 1
Ω
V
DD
= 10 V, R
L
= 2.2
Ω
I
D
≅
4 A, V
GEN
= 4.5 V, R
g
= 1
Ω
f = 1 MHz
0.5
V
DS
= 10 V, V
GS
= 5 V, I
D
= 5.0 A
V
DS
= 10 V, V
GS
= 4.5 V, I
D
= 5.0 A
V
DS
= 10 V, V
GS
= 0 V, f = 1 MHz
865
105
55
12
8.8
1.1
0.7
2.4
8
17
31
8
5
13
21
6
4.8
16
26
47
16
10
20
32
12
ns
Ω
18
14
nC
pF
V
DS
ΔV
DS
/T
J
ΔV
GS(th)
/T
J
V
GS(th)
I
GSS
I
DSS
I
D(on)
R
DS(on)
g
fs
V
GS
= 0 V, I
D
= 250 µA
I
D
= 250 µA
V
DS
= V
GS
, I
D
= 250 µA
V
DS
= 0 V, V
GS
= ± 8 V
V
DS
= 20 V, V
GS
= 0 V
V
DS
= 20 V, V
GS
= 0 V, T
J
= 70 °C
V
DS
≤
5 V, V
GS
= 4.5 V
V
GS
=
4.5 V, I
D
= 5.0 A
V
GS
=
2.5 V, I
D
= 4.7 A
V
GS
=
1.8 V, I
D
= 4.3 A
V
DS
= 10 V, I
D
= 5.0 A
20
0.0265
0.0296
0.0345
24
0.0318
0.0356
0.0414
S
Ω
0.45
20
25
- 2.6
1.0
± 100
1
10
V
mV/°C
V
nA
µA
A
Symbol
Test Conditions
Min.
Typ.
Max.
Unit
Notes:
a. Pulse test; pulse width
≤
300 µs, duty cycle
≤
2 %
b. Guaranteed by design, not subject to production testing.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
2
Document Number: 65900
S10-0641-Rev. A, 22-Mar-10
New Product
Si2312CDS
Vishay Siliconix
TYPICAL CHARACTERISTICS
25 °C, unless otherwise noted
20
V
GS
= 5 V thru 2 V
4
15
I
D
- Drain Current (A)
I
D
- Drain Current (A)
V
GS
= 1.5 V
5
3
10
2
T
C
= 25 °C
1
T
C
= 125 °C
5
V
GS
= 1 V
0
0.0
0
0.0
T
C
= - 55 °C
2.0
0.3
0.6
0.9
1.2
1.5
0.5
1.0
1.5
V
DS
- Drain-to-Source Voltage (V)
V
GS
- Gate-to-Source Voltage (V)
Output Characteristics
0.045
1200
Transfer Characteristics
R
DS(on)
- On-Resistance (Ω)
0.040
900
V
GS
= 1.8 V
0.035
V
GS
= 2.5 V
0.030
V
GS
= 4.5 V
0.025
C - Capacitance (pF)
C
iss
600
300
C
oss
C
rss
0
5
10
15
20
0.020
0
5
10
I
D
- Drain Current (A)
15
20
0
V
DS
- Drain-to-Source Voltage (V)
On-Resistance vs. Drain Current and Gate Voltage
5
I
D
= 5 A
V
GS
- Gate-to-Source Voltage (V)
4
V
DS
= 10 V
3
V
DS
= 5 V
2
V
DS
= 16 V
1
R
DS(on)
- On-Resistance
1.45
(Normalized)
1.70
Capacitance
V
GS
= 2.5 V, I
D
= 4.7 A
1.20
V
GS
= 4.5 V, I
D
= 5 A
0.95
0
0
2
4
6
8
10
0.70
- 50
- 25
0
25
50
75
100
125
150
Q
g
- Total Gate Charge (nC)
T
J
- Junction Temperature (°C)
Gate Charge
On-Resistance vs. Junction Temperature
Document Number: 65900
S10-0641-Rev. A, 22-Mar-10
www.vishay.com
3
New Product
Si2312CDS
Vishay Siliconix
TYPICAL CHARACTERISTICS
25 °C, unless otherwise noted
100
0.06
I
D
= 5 A
R
DS(on)
- On-Resistance (Ω)
I
S
- Source Current (A)
T
J
= 150 °C
0.05
10
0.04
T
J
= 125 °C
T
J
= 25 °C
1
0.03
T
J
= 25 °C
0.1
0.0
0.02
0.3
0.6
0.9
1.2
0
2
4
6
8
V
GS
- Gate-to-Source Voltage (V)
V
SD
- Source-to-Drain Voltage (V)
Source-Drain Diode Forward Voltage
0.9
32
On-Resistance vs. Gate-to-Source Voltage
0.7
I
D
= 250 μA
Power (W)
- 25
0
25
50
75
100
125
150
V
GS(th)
(V)
24
0.5
16
0.3
8
0.1
- 50
0
0.001
0.01
0.1
Time (s)
1
10
100
T
J
- Temperature (°C)
Threshold Voltage
100
Limited by R
DS(on)
*
10
Single Pulse Power (Junction-to-Ambient)
I
D
- Drain Current (A)
100 μs
1 ms
1
10 ms
T
A
= 25 °C
Single Pulse
0.1
BVDSS Limited
0.01
0.1
100 ms
1 s, 10 s
DC
1
10
100
V
DS
- Drain-to-Source Voltage (V)
* V
GS
> minimum V
GS
at which R
DS(on)
is specified
Safe Operating Area, Junction-to-Ambient
www.vishay.com
4
Document Number: 65900
S10-0641-Rev. A, 22-Mar-10
New Product
Si2312CDS
Vishay Siliconix
TYPICAL CHARACTERISTICS
25 °C, unless otherwise noted
7.5
6.0
I
D
- Drain Current (A)
Package Limited
4.5
3.0
1.5
0.0
0
25
50
75
100
125
150
T
C
- Case Temperature (°C)
Current Derating*
2.5
1.2
2.0
0.9
Power (W)
Power (W)
0
25
50
75
100
125
150
1.5
0.6
1.0
0.3
0.5
0.0
0.0
0
25
50
75
100
125
150
T
C
- Case Temperature (°C)
T
A
- Ambient Temperature (°C)
Power Derating, Junction-to-Foot
Power Derating, Junction-to-Ambient
* The power dissipation P
D
is based on T
J(max.)
= 150 °C, using junction-to-case thermal resistance, and is more useful in settling the upper
dissipation limit for cases where additional heatsinking is used. It is used to determine the current rating, when this rating falls below the package
SynQor推出超小的病人全接触型400W医疗电源模块,该电源模块的封装为3×5×1.44,功率密度高达18.3W/立方英寸,转换效率达91%。 SynQor通过推出首款专门针对医疗应用而研制的AC/DC电源模块,使得公司的多元化战略持续成功地延伸至新的医疗领域。ACuQor模块系列实现了在3×5×1.44有限尺寸上提供400W的有用功率。SynQor可以提供48V,36V or 24V的...[详细]
便携式医疗设备的特殊性决定了它们应该是对用户友好的、必须工作在无菌环境下,并且空间占用小、耗能低。 同时,便携式医疗设备还需要足够的计算能力以便处理医疗数据,能够连接到无线或有线接口以便记录和发送数据。从设计人员的角度考虑,上述需求需要低功耗的单片机(MCU)和数字信号控制器(Digital Signal Controller,DSC)。 正是有了嵌入式处理器,设计人员才有可能设...[详细]
控制器局部网CAN(Controller Area Network)属于现场总线的一种,是一种有效支持分布式控制或实时控制的串行通信网络,被公认为是最有前途的现场总线之一。 在工业控制系统中,电动执行器是电动单元组合仪表中一个很重要的执行单元。它由控制电路和执行机构两个在电路上完全独立的部分组成,可接收来自调节器的电控信号,将其线性地转换成机械转角或直线位移,用来操纵风门、挡板、阀门等...[详细]