电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

27-0002-182ATL

产品描述Interconnection Device
产品类别连接器    连接器   
文件大小184KB,共3页
制造商Aries Electronics
下载文档 详细参数 全文预览

27-0002-182ATL概述

Interconnection Device

27-0002-182ATL规格参数

参数名称属性值
Reach Compliance Codecompli
连接器类型INTERCONNECTION DEVICE
Base Number Matches1

文档预览

下载PDF文档
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Cable Length:
“L” in inches
(2” min. length)
Ex: -0002- = 2”
-02.5 = 2.5”
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
“HT”=High temperature cable insulation
“TL” = Tin/Lead Plating
“P”=Polarization stripe included
Bend Options:
“A” = Both ends bent 90?, same direction
“B” = One male end bent 90?
“C” = Both ends bent 90?, opposite direction
“D” = One female end bent 90?
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-186APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
http://www.arieselec.com • info@arieselec.com
NORTH AMERICA
Frenchtown, NJ USA
TEL:(908) 996-6841
FAX:(908) 996-3891
abc
EUROPE
TEL: +44 870 240 0249
FAX: +44 871 919 6033
europe@arieselec.com
11019
REV.H
Page
1 of 3
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
如何自动识别变送器类型?
如果有输出信号4-20mA和0-10V的变送器,如何设计电路自动识别类型,并转换至匹配电路。...
ovo 工业自动化与控制
关于8962产生PWM
请问哪位大哥,我用EasyArm8962编写了下面这个程序,想试着通过按键KEY1改变PWM的输出方式,为什么我的GEN0能够实现按键就正常翻转,而GEN1输出是翻转了,但是幅值变得小的很多,现在纠结中。 ......
zengweitotty 微控制器 MCU
第六届
本帖最后由 paulhyde 于 2014-9-15 09:49 编辑 一、任务   设计并制作一个电压控制LC振荡器。 二、要求   1、基本要求   (1)振荡器输出为正弦波,波形无明显失真。   (2 ......
songbo 电子竞赛
ANT基础原理 没有不能通信 的玩意儿
5G毫米波天线 MIMO视频 超好看 一看就会 看完就忘记那种 rfid低频和高频天线技术-~--这个一般没有归类在天线里 RFID天线接头分类 这个主要记住连接器 匹配ANT运用 请问大家,无 ......
btty038 无线连接
请求帮助
下载 (26.06 KB) 2011-2-12 16:55 ...
wc8114994 stm32/stm8
关于SensorTag设计实现阶段延期的正式说明,请参与者都注意了啊!!
有的网友已经开始发心得,同时每天群里也在如火如荼地对SensorTag进行着讨论交流,看见这些,我们真的非常高兴。:loveliness: 春节即将来临,提前祝大家节日快乐,同时,由于过年,休假、旅 ......
EEWORLD社区 无线连接

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1494  1137  707  1266  1042  6  28  41  51  8 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved