OM1805NMM OM1815NMM
OM1812NMM
HERMETIC SURFACE MOUNT FIXED VOLTAGE POSITIVE
REGULATORS APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Positive Regulators In Hermetic
Surface Mount Package
FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Output Voltages: +5V, +12V, +15V
Output Voltages Set Internally To ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Hi-Rel Screening Available
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed surface
mount package. All protective features are designed into the circuit including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are +5V, +12V, and +15V.
These units are ideally suited for Military applications where a hermetic surface
mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8778201 NX
5962-8777601 NX
5962-8855301 NX
Omnirel Part Number
OM1805NMM
OM1812NMM
OM1815NMM
3.5
4 11 R0
3.5 - 37
OM1805NMM - OM1815NMM
ABSOLUTE MAXIMUM RATINGS
@ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance
θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
θ
JA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120°C/W
a
ELECTRICAL CHARACTERISTICS 5 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= 10V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Min.
4.92
Max.
5.08
5.15
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= 7.5V to 20V
I
O
= 5mA to 1.0A, P < 15 W
•
4.85
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= 7.5V to 20V
5
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= 8.0V to 12V
12
4
•
Load Regulation
(Note 1)
V
RLOAD
I
O
= 5mA to 1.5 Amp
I
O
= 5mA to 1.0Amp
I
O
= 250mA to 750 mA
10
12
•
•
25
6
15
6
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
N
O
∆V
OUT
∆t
T
A
= 25°C,
∆V
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= 35V
1.5
I
O
= 5mA to 1000mA
V
IN
= 7.5V to 20V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
6.5
0.8
0.5
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= 10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
68
2.8
•
60
40
Output Noise Voltage
(Note 3)
Long Term Stability
µV/V
RMS
75
mV
3.5
(Note 3)
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5 - 38
OM1805NMM - OM1815NMM
ELECTRICAL CHARACTERISTICS 12 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= 19V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Min.
11.88
Max.
12.12
12.36
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= 14.5V to 27V
I
O
= 5mA to 1.0 A, P < 15W
•
11.64
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= 14.5V to 27V
18
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= 16V to 22V
50
9
•
Load Regulation
(Note 1)
V
RLOAD
I
O
= 5mA to 1.5 Amp
I
O
= 5mA to 1.0 Amp
I
O
= 250mA to 750 mA
30
32
•
•
60
20
40
6.0
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
N
O
∆V
OUT
∆t
∆V
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= 35V
I
O
= 5mA to 1000mA
V
IN
= 15V to 30V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
•
1.5
6.5
0.8
0.5
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= 10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
61
2.8
•
54
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
MECHANICAL OUTLINE
.140
.015
.075
.140
1
CONNECTION
.075
.140
2
.157
.030
MIN.
Pin 1 Input
Pin 2 Output
Pin 3 Ground
3.5
3
.415
.062
.375
3.5 - 39
OM1805NMM - OM1815NMM
ELECTRICAL CHARACTERISTICS 15 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= 23V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Min.
14.8
Max.
15.2
15.4
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= 18.5V to 30V
I
O
= 5mA to 1.0 A, P < 15W
•
14.6
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= 17.5V to 30V
20
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= 20V to 26V
50
15
•
Load Regulation
(Note 1)
V
RLOAD
I
O
= 5mA to 1.5 Amp
I
O
= 5mA to 1.0 Amp
I
O
= 250mA to 750 mA
25
35
•
•
75
21
45
6.0
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
N
O
∆V
OUT
∆t
T
A
= 25°C,
∆V
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= 35V
1.5
I
O
= 5mA to 1000mA
V
IN
= 18.5V to 30V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
6.5
0.8
0.5
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= 10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
54
2.8
•
52
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
150
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
TYPICAL PERFORMANCE CHARACTERISTICS
3.5
3
T
j
= -55°C
2.5
100
2
2.5
1.5
2
T
j
= 25°C
I
OUT
= 500mA
Ripple Rejection (dB)
I
OUT
= 1A
80
V
OUT
= 5V
Output Current (A)
3.5
60
1.5
1
T
j
= 150°C
1
I
OUT
= 0A
40
V
IN
- V = 8V
DC
+3.5V
rms
I
OUT
= 1A
T
j
= 25°C
0.5
∆V
OUT
= 100MV
0.5
0
0
20
∆V
OUT
= 100mV
5
10
15
20
25
30
35
0
-75-50 -25 0
2 5 5 0 7 5 100 125150
0
10
100
1k
10k
Input To Output Differential (V)
Junction Temperature (°C)
Frequency (Hz)