Tadiran HLC (Hybrid Layer Capacitor)
Model HLC-1520A
1.
Scope
This data sheet describes the mechanical design and performance of Tadiran HLC (Hybrid Layer
Capacitor) model HLC-1520A, optimized for extreme temperatures, used in a Pulses Plus battery.
2.
Characteristics
2.1.
Physical
Length:
Diameter:
Weight:
Discharge
Discharge capacity (at RT):
When charged to 3.67V:
When charged to 3.90V:
Discharge end voltage:
140 A*sec
210 A*sec
2.5V (discharge below 2.5V at RT and
discharge below 2 V at –40
o
C may increase
the HLC internal impedance)
Continuous: 500 mA
Pulse: 2 A
2.2.2.
Charge (constant current)
Max. charge voltage:
Max. charging current:
3.95 V
25 mA
19.7 ± 0.3 mm.
15.1 mm. max.
7.7 ± 0.2 gr.
2.1.1.
2.1.2.
2.1.3.
2.2.
2.2.1.
Electrical
Maximum discharge current:
Rev. D, April 05.
Page 1 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS,
OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS
BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE.
TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
2.2.3. Shelf life (Reversible Capacity):
The table below describes the shelf life at different storage temperatures to 80% of initial
capacity specified at paragraph 2.2.1.
Temperature
RT
60°C
85°C
2.2.4.
HLC used
independently
3 years
4 weeks
1 week
HLC in Pulses Plus battery
10 years
7 years
At least 1 year
Self discharge current in Pulses Plus™ battery:
At RT:
At 80
o
C:
1µA
5µA
2.2.5.
Number of charge-discharge cycles to 80% of initial capacity :
100% DOD
Charged to
3.67V
Charged to
3.90V
4000
1000
10% DOD
40,000
10,000
1% DOD
400,000
100,000
DOD (Depth Of Discharge)
2.2.6.
Cell impedance:
Less than 250 mOhm (at RT @ 1kHz)
Rev. D, April 05.
Page 2 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS,
OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS
BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE.
TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
2.2.7.
Performance Data:
VOLTAGE vs. TIME CURVES for HLC-1520A at Li/SOCl2 potential, 200 mA.
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1
10
100
1000
10000
VOLTAGE V
TIME [msec.]
-40°C
-25°C
RT
72°C
VOLTAGE vs. TIME CURVES for HLC-1520A at Li/SOCl2 potential, 350 mA.
3.8
3.6
3.4
VOLTAGE V
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1
10
100
1000
10000
TIME [msec.]
-40°C
-25°C
RT
72°C
Rev. D, April 05.
Page 3 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS,
OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS
BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE.
TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
VOLTAGE vs. TIME CURVES for HLC-1520A at Li/SO2Cl2 potential, 200 mA.
4.0
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1
10
100
1000
10000
VOLTAGE V
TIME [msec.]
-40°C
-25°C
RT
72°C
VOLTAGE vs. TIME CURVES for HLC-1520A at Li/SO2Cl2 potential, 350 mA.
4.0
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1
10
100
TIME [msec.]
-40°C
-25°C
RT
72°C
1000
10000
Rev. D, April 05.
Page 4 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS,
OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS
BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE.
TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
VOLTAGE V
Discharge capacity vs. OCV for HLC-1520A (at RT, 50mA discharge)
4.0
3.8
3.5
V
OCV
3.3
3.0
2.8
2.5
0.1
1
10
CAPACITY [A*sec]
100
1000
2.3.
Safety:
The HLC successfully passed the following tests:
Short circuit at RT
Short circuit at 55°C
Compression
Impact
Overcharge
High temperature exposure
Shock and vibration
Forced discharge
2.3.1.
Tadiran Batteries performed the tests according to UL 1642 specification for lithium
batteries. The HLC was approved by UL under file no. MH12193 issued on December 7,
2000.
2.3.2.
The HLC is not restricted for air transportation.
Rev. D, April 05.
Page 5 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS,
OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS
BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE.
TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.