●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●Please request for a specification sheet for detailed product data prior to the purchase.
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
2010.11.8 9565SCAVOL12E
FOR CORRECT USE OF SUPER CAPACITORS
1. Please confirm the operating conditions and the specifications of the
Super Capacitors befor using them.
2. The electrolyte of these Super Capacitors is sealed with material such as rubber.
When you use the capacitors for a long time at high temperature, the moisture of
the eleotrolyte evaporates and the equivalent series resistance (E.S.R.) increases.
The fundamental failure mode is the open mode depending on E.S.R. increase.
When using a capacitor, please introduce a safe design assuming unex-
pected capacitor failure, such as redundancy in design and protection from
fire and erroneous operation.
3. Please read 'Notes on Using the Super Capacitor' on page 60 when you design
the circuits using the Super Capacitors.
●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●Please request for a specification sheet for detailed product data prior to the purchase.
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
2010.11.8 9565SCAVOL12E
CONTENTS
page
1. Organization of Super Capacitor Series
……………………………………………………………
2. Performance for Selection
……………………………………………………………………………
…………………………………………………………………
4
5
5
6
7
9
9
3. Characteristics of Super Capacitor
4. Typical Applications
5. Part Number System
6. Rated Specifications
……………………………………………………………………………………
……………………………………………………………………………………
……………………………………………………………………………………
6.1 FC Series(SMD Type)
…………………………………………………………………………
6.2 FM Series
6.3 FG Series
6.4 FT Series
6.5 FY Series
6.6 FR Series
6.7 FS Series
…………………………………………………………………………………………
13
…………………………………………………………………………………………
20
…………………………………………………………………………………………
22
…………………………………………………………………………………………
24
…………………………………………………………………………………………
26
…………………………………………………………………………………………
28
6.8 FA,FE Series
……………………………………………………………………………………
30
6.9 HV Series(High Capacitance Type)
…………………………………………………………
32
7. Packing
……………………………………………………………………………………………………
33
………………………………………………………………
34
8. List of Plating Type and Sleeve Type
9. Measurement Conditions
………………………………………………………………………………
35
10. Notes on Using Super Capacitor
(Electric
Double-Layer Capacitor)
………………………
36
●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●Please request for a specification sheet for detailed product data prior to the purchase.
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
2010.11.8 9565SCAVOL12E
1. Organization of Super Capacitor Series
−25
to 70℃
guaranteed
mA order
back-up
μA
order
back-up
−40
to 85℃
guaranteed
For automatic
mounting
(SMD)
(embossad
taping)
series
3.5 to 5.5V
FC
For automatic
mounting
(radial
taping)
FME
FML
Type
5.5V
series
3.5 to 6.5V
FM
Type
3.5 to 5.5V
FMR
−40
to 85℃
guaranteed
Can Case type
(self-supporting
Type)
series
5.5V
FT
series
3.5 to 5.5V
FG
FGR
Type
5.5V
series
5.5 to 11V
FS
series
3.5 to 5.5V
FY
series
5.5V
FR
series
5.5V
FE
series
5.5 to 11V
FA
For A order
current
series
2.7V
10 to 100F
HV
4 Super Capacitors Vol.12
●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●Please request for a specification sheet for detailed product data prior to the purchase.
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
2010.11.8 9565SCAVOL12E
2. Performance for Selection
Low ESR
kA
Backup current depends on SuperCapacitor
equivalent series resistance (ESR)
Backup current
A
High power
SuperCapacitor
BOX type
High power
SuperCapacitor
HV Series
Low impedance application use
FA, FE, FS, FT, FM Series
mA
High ESR
μ
A
0.01
0.1
1
10
10
2
High impedance application use
FG, FY, FC, FM, FR Series
10
3
1 hour
10
4
10
5
10
6
1 minute
1 day 1 week
10
8
Backup time
1 month
( sec )
10
7
Backup time depends on capacitance
3. Characteristics of Super Capacitor
Super Capacitor can not be used for applications in AC circuit such as ripple absorption because it has high internal resistance
(several hundred mΩ to a hundred
Ω)
compared to aluminum electrolysis capacitor. Thus its main use would be similar to that
of secondary battery such as power back-up in DC circuit. The following list shows the characteristics of Super Capacitors as
compared to aluminum electrolyses capacitors for power back-up and secondary batteries.
Secondary battery
NiCd battery
Back-up ability
Eco-hazard
Operating temperature range
Charge time
Charge/discharge life time
Restrictions on charge/discharge
Flow soldering
Automatic mounting
Safety risks
◎
Cd
−20
to 60
℃
few hours
approx. 500 times
yes
not applicable
not applicable
leakage, explosion
Lithium ion battery
◎
− −
−
−20
to 50
℃
few hours
approx. 500 to 1000 times
yes
not applicable
not applicable
leakage, combustion, explosion, ignition
Capacitor
Aluminum electrolysis capacito
△
− −
−
−55
to 105
℃
few minutes
limitless (*1)
none
applicable
applicable
heat-up, explosion
Super Capacitor
○
− −
−
−40
to 85
℃(FR,FT)
few minutes
limitless (*1)
none
applicable
applicable (FM and FC series)
gas emission (*2)
(*1) Aluminum electrolysis capacitor and Super Capacitor has limited lifetime. However, when used under proper conditions, both can operate
sufficiently within the designed lifetime of the set they are built in.
(*2) There is no harm as it is a mere leak of water vapor which transitioned from water contained in the electrolyte (diluted sulfuric acid).
However, application of abnormal voltage surge exceeding maximum operating voltage may result in leakage and explosion.
Super Capacitors Vol.12 5
●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●Please request for a specification sheet for detailed product data prior to the purchase.
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
SynQor推出超小的病人全接触型400W医疗电源模块,该电源模块的封装为3×5×1.44,功率密度高达18.3W/立方英寸,转换效率达91%。 SynQor通过推出首款专门针对医疗应用而研制的AC/DC电源模块,使得公司的多元化战略持续成功地延伸至新的医疗领域。ACuQor模块系列实现了在3×5×1.44有限尺寸上提供400W的有用功率。SynQor可以提供48V,36V or 24V的...[详细]
随着阅读器与标签价格的降低和全球市场的扩大,射频标识 RFID(以下简称RFID)的应用与日俱增。标签既可由阅读器供电(无源标签),也可以由标签的板上电源供电(半有源标签和有源标签)。由于亚微型无源 CMOS 标签的成本降低,库存和其他应用迅速增加。一些评估表明,随着无源标签的价格持续下降,几乎每一个售出产品的内部都将有一个 RFID 标签。由于无源 RFID 标签的重要性及其独特的工程实现...[详细]