Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1510C Multi-Conductor - Flexible, CM Rated Cable
For more Information
please call
1-800-Belden1
Description:
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil® (100%
coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall
Beldfoil shield and 24 AWG TC drain wire.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
4
24
7x32
TC - Tinned Copper .024
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.) Dia. (in.)
PO - Polyolefin
.008
.040
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
24
Inner Shield Drain Wire Stranding:
Inner Shield Drain Wire Conductor Material:
7x32
TC - Tinned Copper
Inner Jacket
Inner Jacket Material:
Inner Jacket Material
Nom Wall (in.) Nom. Dia. (in.)
.111
PVC - Polyvinyl Chloride .014
Inner Jacket Color Code Chart:
Number Color
1
2
3
4
Brown
Red
Orange
Yellow
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
18
7x26
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
Page 1 of 3
06-23-2009
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1510C Multi-Conductor - Flexible, CM Rated Cable
PVC - Polyvinyl Chloride .037
Outer Jacket Ripcord:
Yes
Overall Cabling
Overall Nominal Diameter:
0.352 in.
Pair
Pair Color Code Chart:
Color
Red & Black
Pair Lay Length & Direction:
Lay Length (in.) Twists/ft. (twist/ft)
1.750
6.850
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-35°C To +75°C
51.900 lbs/1000 ft.
88.400 lbs.
3.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CM
CM
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/ft)
.18
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
31
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
58
Nominal Velocity of Propagation:
VP (%)
66
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
23.3
Page 2 of 3
06-23-2009
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1510C Multi-Conductor - Flexible, CM Rated Cable
Ind. Pair Nominal Shield DC Resistance @ 20
Deg. C:
Max. Operating Voltage - UL:
Voltage
300 V RMS
15.900 Ohm/1000 ft
Max. Recommended Current:
Current
1.05 Amps per conductor @ 25°C
Put Ups and Colors:
Item #
1510C B591000
1510C B59500
Notes:
C = CRATE REEL PUT-UP.
Putup
1,000 FT
500 FT
Ship Weight
72.000 LB
35.500 LB
Color
BLACK, MATTE
BLACK, MATTE
Notes
C
C
Item Desc
4 PR #24 PP FS PVC FS PVC
4 PR #24 PP FS PVC FS PVC
Revision Number: 1
© 2008 Belden, Inc
All Rights Reserved.
Revision Date: 04-18-2008
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
06-23-2009