C O A X I A L
C A B L E S
6.38
Standard Analog Video Cable
RG-6/U Type
Description
Part
No.
Standard
Nominal
Conductor
UL NEC/ Standard Lengths Unit Weight
Core OD
(stranding)
C(UL) CEC
Diameter
Type
Ft.
m
Lbs.
kg Nom. DCR Inch mm
Shielding Nominal OD
Materials
Nom. DCR Inch mm
Nominal
Nom. Nom. Capacitance
Vel.
Imp.
of
(Ω) Prop. pF/Ft. pF/m
Nominal
Attenuation
dB/
dB/
MHz 100 Ft. 100m
21 AWG
Solid .028″ Bare Copper-covered Steel • Two Bare Copper Braids (97% Shield Coverage)
Polyethylene Insulation • Black Polyethylene Jacket
MATV Cable
80°C
8215
1000
304.8
74.0 33.6
21 AWG .185
(solid)
.028″
BCCS
32.0Ω/M′
105.0Ω/km
4.70
(2) BC
.332 8.43
75
66% 20.5 67.2
Braids
97% Shield
Coverage
100% Sweep tested. 5 MHz to 450 MHz.
1.1Ω/M′
3.6Ω/km
1
10
50
100
200
400
700
900
1000
.4
.8
1.9
2.7
4.1
5.9
8.1
9.4
9.8
1.3
2.6
6.2
8.9
13.4
19.4
26.6
30.8
32.1
18 AWG
Solid .037″ Bare Copper • Two Bare Copper Braids (98% Shield Coverage)
Foam Polyethylene Insulation • Black PVC Jacket
80°C
9290
NEC:
CM
CEC:
CM
1000
2000
304.8 60.0 27.3
609.6 120.0 54.5
18 AWG .180
(solid)
.037″
BC
7.5Ω/M′
24.6Ω/km
4.57
(2) BC
.288 7.32
75
78% 17.3 56.7
Braids
98% Shield
Coverage
100% Sweep tested. 5 MHz to 450 MHz.
2.0Ω/M′
6.6Ω/km
1
10
50
100
200
400
700
900
1000
.2
.7
1.7
2.5
3.6
5.3
7.2
8.3
8.8
.7
2.3
5.6
8.2
11.8
17.4
23.6
27.2
28.9
18 AWG
Solid .040″ Bare Copper • Duofoil
®
+ Tinned Copper Braid Shield
Gas-injected Foam HDPE Insulation • Black PVC Jacket
UL AWM
Style 1354
(30V 80°C)
9248
NEC:
CM
CEC:
CM
U-500
500
U-1000
1000
1640
3280
U-152.4 17.0
152.4 18.0
U-304.8 33.0
304.8 33.0
500.0 55.8
1000.0 108.2
7.7
8.2
15.0
15.0
25.3
49.2
18 AWG .180
(solid)
.040″
BC
6.4Ω/M′
21.0Ω/km
4.57
Duofoil
+ 60% TC
Braid
5.6Ω/M′
18.4Ω/km
.270
6.86
75
82%
16.2
53.1
1
10
50
100
200
400
700
900
1000
1
10
50
100
200
400
700
900
1000
1
10
50
100
200
400
700
900
1000
.3
.7
1.5
2.0
2.8
4.0
5.3
6.1
6.5
.3
.66
1.5
2.1
3.1
4.5
6.0
6.9
7.3
.3
.7
1.6
2.2
3.0
4.6
6.6
7.7
8.2
1.0
2.3
4.9
6.6
9.2
13.1
17.4
20.0
21.3
1.0
2.2
4.9
6.9
10.2
14.8
19.7
22.6
23.9
1.0
2.3
5.2
7.2
9.8
15.1
21.6
25.3
26.9
For Plenum versions of 9248,
see 89248 or 82248.
100% Sweep tested. 5 MHz to 450 MHz.
Plenum • Foam FEP Insulation • Black FEP Jacket
200°C
89248
NEC:
CMP
CEC:
CMP FT6
500
†
1000
†
2000
†
152.4
304.8
609.6
18.0 8.2
36.0 16.4
70.0 31.8
18 AWG .170
(solid)
.040″
BC
6.4Ω/M′
21.0Ω/km
4.32
Duofoil
+ 65% TC
Braid
5.1Ω/M′
16.7Ω/km
.222
5.64
75
82%
16.2
53.1
100% Sweep tested. 5 MHz to 450 MHz.
Suitable for Outdoor and Direct Burial applications.
Plenum • Foam FEP Insulation • Natural Flamarrest
®
Jacket
75°C
82248
NEC:
U-1000
†
U-304.8
304.8
CMP
1000
†
CEC:
CMP FT6
32.0 14.5
33.0 15.0
18 AWG .170
(solid)
.040″
BC
6.4Ω/M′
21.0Ω/km
4.32
Duofoil
+ 65% TC
Braid
5.1Ω/M′
16.7Ω/km
.222
5.64
75
82%
16.2
53.1
100% Sweep tested. 5 MHz to 450 MHz.
BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • HDPE = High-density Polyethylene • TC = Tinned Copper
Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference.
1-800-BELDEN-1.
Request quotations of RG/U cables not listed.
†
Spools and/or UnReel
®
cartons are one piece, but length may vary ±10% from length shown.
B e l d e n E l e c t r o n i c s D i v i s i o n
Te c h n i c a l S u p p o r t :
1 - 8 0 0 - B E L D E N - 1
o r
1 - 8 0 0 - B E L D E N - 3
•