Features
Unregulated
Converters
Description
• 6V Output For GaN Driver Applications
• Pot-Core Transformer With Separated Windings
• High 5.2kVDC Isolation In Compact Size
• Low Isolation Capacitance (10pF max.)
• UL And EN Certified
DC/DC Converter
RP-xx06S
1 Watt
3
SIP7 for
GaN Application
3Y
EAR
wa
High slew rate GaN transistor drivers require an isolated 6V supply with high isolation voltage and low
isolation capacitance.
The RP-xx06S series have been specially designed to fulfill this demanding requirement with 5200VDC
isolation and <10pF isolation capacitance. The internal transformer uses a pot-core to physically
separate the input and output windings, yet the converter still fits into an industry standard SIP7 case.
Input voltage options of 5, 12, 15 or 24V are available and the RP-xx06S series is safety certified to the
latest UL/IEC60950 standard.
rranty
Selection Guide
Part
Number
RP-0506S
RP-1206S
RP-1506S
RP-2406S
nom. Input
Voltage
[VDC]
5
12
15
24
Output
Voltage
[VDC]
6
6
6
6
Output
Current
[mA]
167
167
167
167
Efficiency
typ.
(1)
[%]
81
77
83
82
max. Capacitive
Load
(2)
[µF]
1000
1000
1000
1000
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max. Cap. Load is tested at nominal input and full resistive load
Model Numbering
RP- __ 06S
Input Voltage
Output Voltage
Ordering Examples
RP-0506S = 5V Input, 6V Output, Single Output
RP-1506S = 15V Input, 6V Output, Single Output
Single
UL60950-1 certified
IEC/EN60950-1 certified
IEC/EN60601-1 certified
E358085
Specifications
(measured @ Ta= 25°C, nom. Vin, full load unless otherwise specified)
BASIC CHARACTERISTICS
Parameter
Internal Input Filter
Input Voltage Range
nom. Vin =
5VDC
12VDC
15VDC
24VDC
5VDC
12VDC
15VDC
24VDC
5VDC
12VDC
15VDC
24VDC
4.5VDC
10.8VDC
13.5VDC
21.6VDC
5VDC
12VDC
15VDC
24VDC
270mA
120mA
86mA
57mA
20mA
10mA
8mA
7mA
Condition
Min.
Typ.
Max.
capacitors
5.5VDC
13.2VDC
16.5VDC
26.4VDC
Input Current
nom. Vin =
Quiescent Current
nom. Vin =
www.recom-power.com/eval-ref-boards
continued on next page
www.recom-power.com
REV.: 1/2017
ECO-1
RP-xx06S
DC/DC Converter
Specifications
(measured @ Ta= 25°C, nom. Vin, full load unless otherwise specified)
BASIC CHARACTERISTICS
Parameter
Minimum Load
Start-up time
Internal Operating Frequency
Output Ripple and Noise
(3)
20MHz BW
Notes:
Note3: Measurements are made with a 0.1μF MLCC across output (low ESR)
50kHz
75kHz
50mVp-p
Series
Condition
Min.
0%
250ms
120kHz
100mVp-p
Typ.
Max.
Efficiency vs. Load
100
80
Efficiency [%]
60
40
20
0
0
20
RP-2406S
40
60
Output Current [%]
80
100
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
low line to high line, full load
10% to 100% load
5VDC
12VDC
15VDC
24VDC
Condition
Value
±5.0% max.
±1.2% typ.
±8.0% typ. / ±15.0% max.
±7.0% typ. / ±15.0% max.
±4.0% typ. / ±15.0% max.
±3.0% typ. / ±15.0% max.
Accuracy vs. Load
15
10
RP-0506S
Accuracy [%]
5
0
-5
-10
-15
0
20
40
60
80
100
Output Current [%]
ECO-2
REV.: 1/2017
www.recom-power.com
RP-xx06S
DC/DC Converter
Specifications
(measured @ Ta= 25°C, nom. Vin, full load unless otherwise specified)
PROTECTIONS
Parameter
Isolation Voltage
(4)
Isolation Resistance
Isolation Capacitance
Leakage Current
Insulation Grade
according to IEC/EN60950-1 electric strength test
Notes:
Note4: For repeat Hi-Pot testing, reduce the ime and/or the test voltage
I/P to O/P
Series
Type
tested for 1 second
rated for 1 minute
Value
5.2kVDC
2kVAC / 60Hz
15GΩ min.
10pF max.
0.35μA
Basic
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
Operating Altitude
Operating Humidity
Pollution Degree
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
+80°C
0.1m/s, horizontal
according to EN/IEC60601-1 report
non-condensing
Condition
without derating @ natrual convection (0.1m/s, see graph)
Value
-40°C to +80°C
+105°C
±0.03%/°C
53°C/W
3000m
95% RH max.
PD2
10100 x 10
3
hours
6900 x 10
3
hours
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
80
60
40
30
20
0
-40
Output Power [%]
-20
0
20
40
60
80
95
100 120
Ambient Temperature [°C]
www.recom-power.com
REV.: 1/2017
ECO-3
RP-xx06S
DC/DC Converter
Specifications
(measured @ Ta= 25°C, nom. Vin, full load unless otherwise specified)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Information Technology Equipment, General Requirements for Safety
Information Technology Equipment, General Requirements for Safety
Medical Electric Equipment, General Requirements for Safety and Essential
Performance
Risk Management
RoHs 2+
Series
Report / File Number
SPCLVD1602031
E358085-A6-UL
SPCMDD1205098-4
RM120598
Standard
IEC60950-1, 2nd Edition, 2005 + Am2, 2013
EN60950-1, 2006 + Am2, 2013
UL60950-1, 1st Edition, 2007
CAN/CSA C22.2 No. 60950-1, 1st Edition, 2006
IEC60601-1, 2005 + CORR 2, 2007
EN60601-1, 2006
ISO14971:2007
RoHS 10/10, 2011/65/EU + AM-2015/863
EMC Compliance
Information techwnology equipment - Radio disturbance characteristics -
Limits and methods of measurement
Condition
without external filter
Standard / Criterion
EN55022, Class A or B
EMI Filtering according to EN55022 Class A & B
C2
L1
+VIN
+VOUT
C1
-VIN
-VOUT
Component List Class A
C1
22μF
C2
470pF, 6kVDC
L1
N/A
Component List Class B
MODEL
RP-0506S
RP-1206S
RP-1506S
RP-2406S
C1
10μF
4.7μF
2.2μF
C2
470pF, 6kVDC
L1
10μH
22μH
47μH
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
Type
Case
Potting
Value
black plastic, (UL94V-0)
Epoxy, (UL94V-0)
19.65 x 7.05 x 10.2mm
2.6g
continued on next page
ECO-4
REV.: 1/2017
www.recom-power.com
RP-xx06S
DC/DC Converter
Specifications
(measured @ Ta= 25°C, nom. Vin, full load unless otherwise specified)
Dimension Drawing (mm)
embossed logo
Series
19.65
7.05
Pin Connections
10.2
RP-xx06S
4.10
0.5
Pin #
Marking
Single
+Vin
-Vin
-Vout
+Vout
****
1
2
5
7
0.5
Recommended Footprint Details
1.00 Ø +0.15/-0
2.54
XX.X ± 0.5mm
XX.XX ± 0.25mm
0.25
1
2
5
6x2.54 = 15.24
7
2.0
1.27
Bottom View
Top View
2.54
INSTALLATION and APPLICATION
+5V
IC1
6V
C1
0V
R1
C2
GND
6V
IC2
GND
Si8271
VDD
PWM IN
+5V
0V
EN
VI
VDDI
C4
R2
R4
GaN
Vo+
Vo-
GNDA
C3
EN
GNDI
R3
R5
GND
GND
Isolation
PACKAGING INFORMATION
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidity
tube
tube
520.0 x 16.0 x 9.mm
25pcs
-55°C to +125°C
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 1/2017
ECO-5