STANDARD RF INDUCTORS - SURFACE MOUNT
MG1008
COMPLIANT
RoHS
Wirewound, Non-Magnetic, Open Construction
PART
NUMBER
MG1008-010*
1
MG1008-012*
1
MG1008-015*
1
MG1008-018*
1
MG1008-022*
1
MG1008-024*
1
MG1008-027*
1
MG1008-033*
1
MG1008-039*
1
MG1008-047*
1
MG1008-056*
1
MG1008-068*
1
MG1008-082*
1
MG1008-100*
1
MG1008-120*
1
MG1008-150*
1
MG1008-180*
1
MG1008-220*
1
MG1008-270*
1
MG1008-330*
1
MG1008-390*
1
MG1008-470*
1
MG1008-560*
1
MG1008-620*
1
MG1008-680*
1
MG1008-750*
1
MG1008-820*
1
MG1008-910*
2
MG1008-101*
2
MG1008-121*
2
MG1008-151*
2
L
nH
10
12
15
18
22
24
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
620
680
750
820
910
1000
1200
1500
L
TEST
FREQ MHz
50
50
50
50
50
50
50
50
50
50
50
50
50
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
7.9
7.9
Q
MIN
50
53
70
50
55
50
58
65
60
65
65
67
63
63
60
50
45
46
48
51
47
54
56
49
46
46
52
37
36
35
35
Q
TEST
FREQ MHz
CERAMIC CORE
500
500
500
350
350
350
350
350
350
350
350
350
350
350
350
100
100
100
100
100
100
100
100
100
100
100
100
100
100
50
50
SRF
MHz
MIN
4100
3300
2500
2500
2400
1600
1600
1600
1500
1500
1300
1300
1000
1000
950
850
750
700
600
570
500
450
415
375
375
360
350
320
290
250
200
DCR
OHMS
MAX
0.080
0.090
0.100
0.110
0.120
0.130
0.130
0.140
0.150
0.160
0.180
0.200
0.220
0.560
0.630
0.700
0.770
0.840
0.910
1.05
1.12
1.19
1.33
1.40
1.47
1.54
1.61
1.68
1.75
2.00
2.30
CURRENT
RATING
mA DC
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
650
650
620
620
620
600
470
470
470
400
400
400
400
400
380
370
310
330
*
1
Substitute “J” for 5% tolerance or “G” for 2% tolerance
*
2
Substitute “K” for 10% tolerance, “J” for 5% tolerance or “G” for 2% tolerance
continued next page
These RoHS components meet the ≤ 0.1% lead requirement and they are compatible with 260° soldering processes.
NOTES:
• Operating Temperature Range:
-40°C to +150°C
• Current Rating is based on a 30°C temperature
rise at an ambient temperature of 120°C
• Relative Permeability: ≤0.00003 µr
• Medical Grade
• Terminations are Silver, spot welded
• Specifically designed for use in imaging
equipment where non-magnetic coils are required
• No internal solder connection increases reliability
• Extremely high SRF
• Applications include: electronic test equipment,
medical equipment, telecommunications,
disk drives, computers and modems, aviation
equipment, navigation equipment and cable TV
TAPE AND REEL SPECS:
in. (mm)
0.114
(2.90)
MAX
0.047
(1.20)
REF
0.083
(2.10)
MAX
0.097
(2.47)
REF
0.020
(0.51)
REF
0.057
(1.45)
REF
0.006/0.016
(0.15/0.40)
0.020
(0.51)
REF
0.110
(2.80)
MAX
RECOMMENDED FOOTPRINT
0.039
(1.0)
0.051
(1.3)
0.098
(2.5)
0.080
(2.03)
REF
0.039
(1.0)
Pcs./Reel maximum
Pitch between parts:
Tape width:
Reel diameter:
1000 or 2000
4 mm
8 mm
7 in.
One Magnetics Pkwy, Gowanda, NY 14070 • (t) 1-716-532-2234 • (f) 1-716-532-2702 • sales@gowanda.com
www.gowanda.com
A n A f f i l i a t e o f G o w a n d a C o m p o n e n t s G r o u p • w w w. G o w a n d a C o m p o n e n t s G r o u p . c o m
071918
STANDARD RF INDUCTORS - SURFACE MOUNT
MG1008
COMPLIANT
RoHS
Wirewound, Non-Magnetic, Open Construction
PART
NUMBER
MG1008-181*
2
MG1008-221*
2
MG1008-271*
2
MG1008-331*
2
MG1008-391*
2
MG1008-471*
2
MG1008-561*
2
MG1008-681*
2
MG1008-821*
2
L
nH
1800
2200
2700
3300
3900
4700
5600
6800
8200
L
TEST
FREQ MHz
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
Q
MIN
34
28
23
22
27
20
22
22
24
Q
TEST
FREQ MHz
CERAMIC CORE
50
50
25
25
25
25
7.9
7.9
7.9
SRF
MHz
MIN
160
160
140
110
100
65
55
48
44
DCR
OHMS
MAX
2.60
2.80
4.80
5.10
5.40
6.00
6.50
7.50
8.40
CURRENT
RATING
mA DC
300
280
120
120
110
110
110
110
110
*
1
Substitute “J” for 5% tolerance or “G” for 2% tolerance
*
2
Substitute “K” for 10% tolerance, “J” for 5% tolerance or “G” for 2% tolerance
continued next page
These RoHS components meet the ≤ 0.1% lead requirement and they are compatible with 260° soldering processes.
0.114
(2.90)
MAX
0.047
(1.20)
REF
0.083
(2.10)
MAX
0.097
(2.47)
REF
0.020
(0.51)
REF
0.057
(1.45)
REF
0.006/0.016
(0.15/0.40)
0.020
(0.51)
REF
0.110
(2.80)
MAX
RECOMMENDED FOOTPRINT
0.039
(1.0)
0.051
(1.3)
0.098
(2.5)
0.080
(2.03)
REF
0.039
(1.0)
NOTES:
• Operating Temperature Range:
-40°C to +150°C
• Current Rating is based on a 30°C temperature
rise at an ambient temperature of 120°C
• Relative Permeability: ≤0.00003 µr
• Medical Grade
• Terminations are Silver, spot welded
• Specifically designed for use in imaging
equipment where non-magnetic coils are required
• No internal solder connection increases reliability
• Extremely high SRF
• Applications include: electronic test equipment,
medical equipment, telecommunications,
disk drives, computers and modems, aviation
equipment, navigation equipment and cable TV
TAPE AND REEL SPECS:
in. (mm)
Pcs./Reel maximum
Pitch between parts:
Tape width:
Reel diameter:
1000 or 2000
4 mm
8 mm
7 in.
One Magnetics Pkwy, Gowanda, NY 14070 • (t) 1-716-532-2234 • (f) 1-716-532-2702 • sales@gowanda.com
www.gowanda.com
A n A f f i l i a t e o f G o w a n d a C o m p o n e n t s G r o u p • w w w. G o w a n d a C o m p o n e n t s G r o u p . c o m
071918
STANDARD RF INDUCTORS - SURFACE MOUNT
continued from previous page
MG1008
COMPLIANT
RoHS
Wirewound, Non-Magnetic, Open Construction
Typical Q vs. Frequency
!
Typical Ls vs. Frequency
!
!
One Magnetics Pkwy, Gowanda, NY 14070 • (t) 1-716-532-2234 • (f) 1-716-532-2702 • sales@gowanda.com
www.gowanda.com
A n A f f i l i a t e o f G o w a n d a C o m p o n e n t s G r o u p • w w w. G o w a n d a C o m p o n e n t s G r o u p . c o m
071918