Technical specification:
Rated voltage:
IEC 60664-1
Overvoltage category:
IEC 60664-1
300 V
2
2,7 kV
0,75mm²
8A
>=100 M
1,5mm²
10 A
A
Ø26
Ø14,05
Overvoltage:
IEC 60664-1
Current rating:
IEC 60512-3 at 40°C
Insulation resistance:
IEC 60512
Pollution degree:
IEC 60664-1
3/2
IP 68, in mated
condition
-30° ... +80°
C
C
>=100
crimped
54
Degree of protection:
IEC 60529
L
3
Temperature range:
Mating cycles:
IEC 60512-9a
Termination:
Materials:
Contact:
Contact plating:
Contact carrier:
Contact assignment:
n
19
D
CuZn
Nickel, gold plated
TPU, UL 94
CuZn, nickel plated
TPU, UL 94, grey
A
3
1
1
2
3
4
brown
white
blue
black
Coupling nut:
Moulding body:
4
2
Part no:
41-01036
41-01037
41-01038
41-01039
41-xxxxx
41-01133
41-01134
41-01135
41-01136
Description:
SAL - 7/8 - RK4 - 2 / K1
SAL - 7/8 - RK4 - 3 / K1
SAL - 7/8 - RK4 - 5 / K1
SAL - 7/8 - RK4 - 10 / K1
SAL - 7/8 - RK4 - ... / K1
SAL - 7/8 - RK4 - 2 / K1 / 150
SAL - 7/8 - RK4 - 3 / K1 / 150
SAL - 7/8 - RK4 - 5 / K1 / 150
SAL - 7/8 - RK4 - 10 / K1 / 150
SAL - 7/8 - RK4 - ... / K1 / 150
Length L: Cable:
2m
3m
5m
10m
x
2m
3m
5m
10m
x
TPU, UL 20549,
black, 4x1,50mm²
Cable: 781-K1840G
TPU, UL 20549,
black, 4x0,75mm²
Cable: 781-K1740G
D see data sheet cable
DO NOT ALTER CAD DRAWING BY HAND
41-xxxxx
dim. in mm
date
drawn
19.10.07
appd.
Directive 2011/65/EU RoHS compliant
Index: d 24.04.14 MG Ä5178
Cable 781-K18400 superseded by
781-K1840G, data sheet revised,
temperature range: IEC removed
tolerance of cable:
title:
name
Female connector 7/8" axial
dwg no:
R
L <= 4m: L + 40mm
L > 4m: L + 1%
0
0,0
0,00
± 0,50mm
± 0,25mm
± 0,10mm
Mankopf
Franz
19.10.07
general tolerance:
41K1A318
part no:
THIS DRAWING MAY NOT BE COPIED OR REPRODUCED IN ANY WAY, AND
MAY NOT BE PASSED ON TO A THIRD PARTY WITHOUT WRITTEN PERMISSION.
OWNERSHIP AND COPYRIGHT OF CONEC GmbH
see table