804-022-DD0ZNU14-235PA-72

产品描述Interconnection Device
产品类别连接器    连接器   
文件大小508KB,共4页
制造商Glenair
官网地址http://www.glenair.com/
下载文档 详细参数 全文预览

804-022-DD0ZNU14-235PA-72概述

Interconnection Device

804-022-DD0ZNU14-235PA-72规格参数

参数名称属性值
厂商名称Glenair
Reach Compliance Codecompliant
其他特性GENDER: FEMALE
连接器类型INTERCONNECTION DEVICE

文档预览

下载PDF文档
804-015
Glenair’s ASAP Mighty Mouse
Overmolded Cordsets
offer
environmental protection and
excellent cold temperature flexibility.
These cables are 100% tested and
ready to use. Standard overmolded
cables feature low smoke zero
halogen polyurethane jackets.
Tired of set-up charges and factory
minimums?
Glenair’s Mighty Mouse ASAP
cordsets have no minimum order quantity
and no lot charges.
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 804 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
G
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 750 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
G-21
Rev. 01-JANUARY-2010
Series 804
Series 804 Push-Pull Mighty Mouse
Overmolded ASAP Cordset Ordering Information
TI 430打折了
四款MSP430热门开发工具! 8月21日到9月8日! 全球500套,数量有限,售完即止 还等什么? 立刻下单! 本次促销优惠活动每位客户的每张折扣券只允许使用一次,活动截止日期是9 月 8日。 ......
568760310 淘e淘
1
1...
han0602 嵌入式系统
Zigbee,无线传感网WSN,CC2530的休眠怎么实现的?
Zigbee,无线传感网WSN,CC2530的休眠怎么实现的?电源供电是太阳能模块,能提供给大概200mw。...
dingshidong TI技术论坛
基于msp430g2553+nrf24L01
求一个基于msp430g2553和nrf24L01制作的一个接受、发射器程序代码;ccs5.0的编程软件、...
junggle 微控制器 MCU
J-link无法使用的解决方法,更新固件,基本可以解决大多问题
前几天,自己用的J-link莫名的不能使用了,指示灯不亮,正常状态是保持绿灯,后来听说更新固件可以解决大部分的问题,就试了一次,果然又可以重新使用了,希望有遇到同样问题的朋友,少走弯路, ......
zyc1 微控制器 MCU
Broad-Band Diode Phase Shifters
Abstract—Design figures are presented for four types of diodephase shifters: switched line, reflection, loaded line, and a new typeusing lumped-element high-pass and low-pass circ ......
JasonYoo 测试/测量

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 219  2352  12  359  983  5  48  1  8  20 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved