电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

A308425

产品描述Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
产品类别连接器   
文件大小239KB,共6页
制造商Eaton
下载文档 详细参数 全文预览

A308425概述

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

A308425规格参数

参数名称属性值
厂商名称Eaton
Reach Compliance Codecompliant
ECCN代码EAR99
其他特性SAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
紧固方法SCREW
制造商序列号A3000
安装类型BOARD
层数1
行数1
通路数25
额定电流30 A
额定电压600 V
安全认证UL; CSA; CE; IEC
端子和端子排类型BARRIER STRIP TERMINAL BLOCK
线规12 AWG

文档预览

下载PDF文档
MAGNUM
®
A31940707WR
Series A3000, LP3000 & CB3000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A3:
30A, 600V* #12-22 AWG
LP3: 30A, 150V #12-22 AWG
CB3: 30A, 600V #12-22 AWG
Wire Range:
#12-22 AWG CU
Center Spacing:
.437” or 7/16” (11.10 mm)
Screw Size:
#6-32 zinc plated philslot screws.
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing.
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature:
105°C (221°F) max., -40°C
(-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3500V (A3 & LP3); 8200V (CB3)
Agency Information:
UL/CSA; IEC Compliance,
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal;
20 Rating without ring terminal.
LP301105
CB31420807
A3000 & LP3000 Series
.437
(11.10)
.15
(3.8)
dia.
.65
(16.5)
Base & Rail Mount
Connectors
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.75
9.18
9.62
10.06
10.50
10.93
11.37
11.81
1.73
2.17
2.61
3.05
3.48
3.92
4.36
4.80
5.23
5.67
6.11
6.55
6.98
7.42
7.86
8.30
8.73
9.17
9.60
10.05
10.48
10.92
11.36
11.80
12.23
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.43
.87
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.50
9.18
9.62
10.06
10.50
10.93
11.37
11.81
BARRIER
ENDS
ONLY
C
Length
.98
1.43
1.87
2.31
2.75
3.18
3.62
4.06
4.50
4.93
5.37
5.81
6.25
6.68
7.12
7.56
8.00
8.43
8.87
9.31
9.75
10.18
10.62
11.06
11.50
11.93
12.37
.40
(10.2)
C
Mount End
Barrier End
.565
(19.3)
.76
(14.35)
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB3000 Series
.437
(11.10)
.19
(4.8)
dia.
.32
(8.1)
C
Mount End
Barrier End
Power Distribution Blocks
.70
(17.8)
.61
(15.5)
WIRE MANAGEMENT PRODUCTS
Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
12
M8+LCD1602+LM35的电池容量测试仪
http://www.ouravr.com/bbs/bbs_upload23560/files_5/armok01104426.JPG http://www.ouravr.com/bbs/bbs_upload23560/files_5/armok01104427.JPG http://www.ouravr.com/bbs/bbs_upload2356 ......
bigcat1980 单片机
四旋翼
想做四旋翼,求各位大大给推荐几款单片机...
刘123 单片机
嵌入式USB主机,有经验的开发者给点意见,谢!
我最近查了些资料 现在把我的需求在整理一下:我想做一个嵌入式USB主机(强调是主机端host,不是USB设备),这是第一次做一个完整的系统,不知从何入手,有这样几个问题,首先是主控芯片,如果 ......
yishengbubian 嵌入式系统
求大神帮我看看这个电路
本帖最后由 xinmeng_wit 于 2016-11-2 12:41 编辑 正常情况下A,B两点应该是有正弦波的,C点应该是方波,求大神帮忙分析一下原理。L是线圈。265178...
xinmeng_wit 模拟电子
ARM板开发触摸屏程序,出现飘屏!急求解决办法!
我用ARM板测试一个触摸屏程序,偶尔出现飘屏! 源码如下: #include "def1.h" #include "2440addr.h" #include "2440lib.h" #include "config.h" #define REQCNT 30 #define ADC ......
lyzj321 ARM技术
立式、卧式、陶磁晶振的区别
谁能告诉我立式、卧式、陶磁晶振的区别是什么?非常感谢!...
xiaoyu123 测试/测量

技术资料推荐更多

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1297  2719  250  2738  2422  27  55  6  56  49 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved