Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
5502UG Multi-Conductor - Residential, Light Commercial and Institutional Applications
For more Information
please call
1-800-Belden1
Description:
22 AWG stranded (7x30) bare copper conductors, polypropylene insulation, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
4
22
7x30
BC - Bare Copper
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PP - Polypropylene .006
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .015
Overall Cable
Overall Cabling Color Code Chart:
Color
Black
Red
White
Green
Overall Nominal Diameter:
0.131 in.
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-20°C To +75°C
75°C
13 lbs/1000 ft.
36.400 lbs.
1.300 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
NEC Articles:
CEC/C(UL) Specification:
EU CE Mark:
CM
800
CM
Yes
Page 1 of 3
02-24-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
5502UG Multi-Conductor - Residential, Light Commercial and Institutional Applications
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
CSA Flame Test:
UL1685 UL Loading
FT1
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
20
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
16.2
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
2.2 Amps per conductor @ 25°C
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
5502UG U4FC500
5502UG U4FU1000
5502UG 001C500
5502UG 001U1000
5502UG 003C1000
5502UG 003C500
5502UG 004C1000
5502UG 004C500
5502UG 004U1000
5502UG 005C500
5502UG 006C1000
5502UG 006C500
5502UG 006U1000
5502UG 007C1000
5502UG 007C500
5502UG 007U1000
5502UG 008C1000
5502UG 008C500
5502UG 008U1000
5502UG 008U500
5502UG 009C1000
Putup
500 FT
1,000 FT
500 FT
1,000 FT
1,000 FT
500 FT
1,000 FT
500 FT
1,000 FT
500 FT
1,000 FT
500 FT
1,000 FT
1,000 FT
500 FT
1,000 FT
1,000 FT
500 FT
1,000 FT
500 FT
1,000 FT
Ship Weight
6.500 LB
14.000 LB
6.500 LB
14.000 LB
13.000 LB
6.500 LB
13.000 LB
6.500 LB
14.000 LB
6.500 LB
13.000 LB
6.500 LB
14.000 LB
13.000 LB
6.500 LB
14.000 LB
13.000 LB
6.500 LB
14.000 LB
7.500 LB
13.000 LB
Color
BEIGE U4F
BEIGE U4F
BROWN
BROWN
ORANGE
ORANGE
YELLOW
YELLOW
YELLOW
GREEN, DARK
BLUE, LIGHT
BLUE, LIGHT
BLUE, LIGHT
VIOLET
VIOLET
VIOLET
GRAY
GRAY
GRAY
GRAY
WHITE
Notes
Item Desc
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
4 #22 PP FRPVC
Page 2 of 3
02-24-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
5502UG Multi-Conductor - Residential, Light Commercial and Institutional Applications
5502UG 009C500
5502UG 009U1000
500 FT
1,000 FT
6.500 LB
14.000 LB
WHITE
WHITE
4 #22 PP FRPVC
4 #22 PP FRPVC
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 05-14-2007
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
02-24-2012