The MINMAX MIHW3000 series is a range of high performance DC/DC converter modules with a reinforced insulation system .The I/O- isolation voltage is
specified for 4000VACrms.The product comes in a small DIP-24 package. All 12 models features wide 2:1 input voltage range and fully regulated output
voltage.
The MIHW3000 DC/DC converters offer an economical solution for demanding applications in industrial and medical instrumentation requesting a certified
high supplementary or reinforced insulation system to comply with relative industrial or medical safety standards.
Model Selection Guide
Model
Number
Input
Voltage
(Range)
VDC
MIHW3022
MIHW3023
MIHW3026
MIHW3027
MIHW3032
MIHW3033
MIHW3036
MIHW3037
MIHW3042
MIHW3043
MIHW3046
MIHW3047
12
(9 ~ 18)
Output
Voltage
VDC
5
12
±12
±15
5
12
±12
±15
5
12
±12
±15
Output Current
Max.
mA
1000
500
±250
±200
1000
500
±250
±200
1000
500
±250
±200
Min.
mA
200
100
±50
±40
200
100
±50
±40
200
100
±50
±40
Input Current
@Max. Load
mA(typ.)
570
641
641
641
278
313
313
313
139
156
156
156
@No Load
mA(typ.)
Reflected
Ripple
Current
mA (typ.)
Max. capacitive
Load
uF
1000
470
220#
220#
1000
470
220#
220#
1000
470
220#
220#
# For each output
Efficiency
(typ.)
@Max. Load
%
75
78
78
78
77
80
80
80
77
80
80
80
30
60
24
(18 ~ 36)
20
30
48
(36 ~ 75)
10
15
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Model
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
Min.
-0.7
-0.7
-0.7
7
13
30
---
---
---
---
Typ.
---
---
---
8
15
33
---
---
---
---
Pi Filter
---
---
2500
mW
Compliance to EN55022,class A and FCC part 15,class A
Max.
25
50
100
9
18
36
8.5
16
34
3000
Unit
Start-Up Voltage
VDC
Under Voltage Shutdown
Short Circuit Input Power
Input Filter
Internal Power Dissipation
Conducted EMI
mW
All Models
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/05/18 REV:8
Page 1 of 4
®
MIHW3000 SERIES
DC/DC CONVERTER 6W,
Reinforced Insulation, Medical Safety
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Foldback
25% Load Step Change
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=25% to 100%
5V Output Models
Other Output Models
Over Line, Load & Temp.
Conditions
Min.
---
---
---
---
---
---
---
---
---
---
---
120
Continuous
Typ.
±0.5
±0.5
±0.3
±0.5
75
100
---
---
300
±3
±0.02
150
Max.
±1.0
±2.0
±0.5
±1.0
100
150
180
25
500
±6
±0.05
---
Unit
%
%
%
%
mV
P-P
mV
P-P
mV
P-P
mV rms
uS
%
%/℃
%
Isolation, Safety Standards
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Test Voltage
Leakage Current
I/O Isolation Resistance
I/O Isolation Capacitance
Safety Standards
Conditions
60 Seconds
Flash tested for 1 Second
240VAC, 60Hz
500 VDC
100KHz, 1V
Min.
4000
6000
---
10
Typ.
---
---
---
---
Max.
---
---
2
---
13
Unit
VACrms
V
PK
uA
G
pF
Approvals
---
7
cUL/UL60950-1, CSA C22.2 No. 60950-1-03
UL60601-1,CSA C22.2 No.601-1,
IEC/EN 60950-1, IEC/EN 60601-1
IEC60950-1 CB report, cUL/UL 60950-1 certificate
UL60601-1 UL certificate
General Specifications
Parameter
Switching Frequency
MTBF(calculated)
MIL-HDBK-217F@25℃, Ground Benign
Conditions
Min.
---
700,000
Typ.
150
-----
Max.
---
-----
Unit
KHz
Hours
Input Fuse
12V Input Models
1200mA Slow-Blow Type
24V Input Models
600mA Slow-Blow Type
48V Input Models
300mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
-40
---
-50
---
Free-Air convection
---
260
℃
Max.
+75
+95
+125
95
Unit
℃
℃
℃
% rel. H
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/05/18 REV:8
Page 2 of 4
®
MIHW3000 SERIES
DC/DC CONVERTER 6W,
Reinforced Insulation, Medical Safety
Power Derating Curve
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
Ripple & Noise measurement bandwidth is 0-20 MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however, they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
Specifications subject to change without notice.
Package Specifications
Mechanical Dimensions
3.8 12.0 [0.47]
[0.15]
0.5 [0.02]
Output Power (%)
Pin Connections
Pin
1
11
12
13
15
23
24
1
11
12
Single Output
+Vin
No Pin
-Vout
+Vout
No Pin
-Vin
-Vin
Dual Output
+Vin
Common
On Pin
-Vout
+Vout
--Vin
-Vin
0.60 [0.024]
15.22 [0.60]
15
13
Bottom View
24
23
20.3 [0.80]
►
All dimensions in mm
(inches)
2.54
[0.10]
2.54
[0.10]
20.32 [0.80]
31.8 [1.25]
5.08
[0.20]
2.0
[0.08]
►
Tolerance: X.X±0.25
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►
Pin
►
Pin
pitch tolerance: ±0.25 (0.01)
tolerance: ±0.05 (0.002)
Physical Characteristics
Case Size
Case Material
Weight
:
:
:
31.8x20.3x12.0mm (1.25x0.8x0.47 Inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
18g
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/05/18 REV:8
Page 3 of 4
®
MIHW3000 SERIES
DC/DC CONVERTER 6W,
Reinforced Insulation, Medical Safety
Test Configurations
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0 at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
Battery
+
Lin
+Vin
Current
Probe
+Out
Load
DC / DC
Converter
-Vin
-Out
Cin
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
Single Output
DC / DC
Converter
-Vin
-Out
+Out
Copper Strip
Cout
Copper Strip
Resistive
Scope
Load
+Vin
Dual Output
DC / DC
Converter
-Vin
+Out
Com.
-Out
Copper Strip
Cout
Copper Strip
Cout
Copper Strip
Scope
Scope
Resistive
Load
Design & Feature Considerations
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. By using a
good quality low Equivalent Series Resistance (ESR < 1.0 at 100 kHz) capacitor of a 10uF for the 12V input devices and a 4.7uF for the 24V input devices and a
2.2uF for the 48V devices, capacitor mounted close to the power module helps ensure stability of the unit.
+
DC Power
Source
-
+
Cin
-Vin
-Out
+Vin
DC / DC
Converter
+Out
Load
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3uF capacitors at the output.
+
DC Power
Source
-
-Vin
+Vin
Single Output
DC / DC
Converter
-Out
+Out
+
DC Power
Source
-
-Vin
+Vin
+Out
Dual Output
DC / DC
Com.
Converter
-Out
Cout
Cout
Load
Load
Cout
Load
Maximum Capacitive Load
The MIHW3000 series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up,
affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data
sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
Design & Feature Considerations
Conducted and radiated emissions < A
with external coupling capacitor Cio=1 nF < B
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
EtherCAT(Ethernet for Control Automation Technology)是一种基于以太网的开发构架的实时工业现场总线通讯协议,EtherCAT是最快的工业以太网技术之一,同时它提供纳秒级精确同步。相对于设置了相同循环时间的其他总线系统,EtherCAT系统结构通常能减少25%-30%的CPU负载,EtherCAT的出现为系统的实时性能和拓扑的灵活性树立了新的标准。...[详细]