The MINMAX MDW1 series is a range of isolated 2W DC/DC converter modules featuring fully regulated output voltages and wide 2:1 input voltage ranges.
The products come in a compact DIP-16 package with a low height of just 7.60 mm (0.30 inch). An excellent efficiency allows an operating temperature
range of –40°C to +80°C.
These DC/DC converters offer an economical solution for many cost critical applications in battery-powered equipment and instrumentation.
Model Selection Guide
Model
Number
Input
Voltage
(Range)
VDC
Output
Voltage
VDC
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
Output Current
Max.
mA
500
400
167
134
±200
±83
±67
500
400
167
134
±200
±83
±67
500
400
167
134
±200
±83
±67
500
400
167
134
±200
±83
±67
Min.
mA
125
100
42
33
±50
±21
±17
125
100
42
33
±50
±21
±17
125
100
42
33
±50
±21
±17
125
100
42
33
±50
±21
±17
Input Current
@Max. Load
mA(typ.)
471
548
534
582
667
615
598
184
217
209
220
242
224
226
96
109
109
108
119
112
110
49
57
53
55
62
57
57
@No Load
mA(typ.)
Reflected
Ripple
Current
mA(typ.)
Max. capacitive
Load
uF
2200
1000
170
110
470#
100#
47#
2200
1000
170
110
470#
100#
47#
2200
1000
170
110
470#
100#
47#
2200
1000
170
110
470#
100#
47#
# For each output
Efficiency
(typ.)
@Max. Load
%
70
73
75
73
64
69
71
73
77
80
80
73
78
78
72
77
80
81
74
78
80
71
73
79
79
71
77
77
MDW1011
MDW1012
MDW1013
MDW1014
MDW1015
MDW1016
MDW1017
MDW1021
MDW1022
MDW1023
MDW1024
MDW1025
MDW1026
MDW1027
MDW1031
MDW1032
MDW1033
MDW1034
MDW1035
MDW1036
MDW1037
MDW1041
MDW1042
MDW1043
MDW1044
MDW1045
MDW1046
MDW1047
5
(4.5 ~ 9)
40
100
12
(9 ~ 18)
20
25
24
(18 ~ 36)
10
15
48
(36 ~ 75)
8
10
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/08/11 REV:6
Page 1 of 4
®
MDW1000 SERIES
DC/DC CONVERTER 2W,
DIP-Package
Input Specifications
Parameter
Model
5V Input Models
12V Input Models
24V Input Models
48V Input Models
5V Input Models
12V Input Models
24V Input Models
48V Input Models
5V Input Models
12V Input Models
24V Input Models
48V Input Models
Min.
-0.7
-0.7
-0.7
-0.7
3.5
4.5
8
16
---
---
---
---
---
---
---
Typ.
---
---
---
---
4
7
12
24
3.5
6.5
11
22
---
---
---
Max.
11
25
50
100
4.5
9
18
36
4
8.5
17
34
1
1500
1800
VDC
Unit
Input Surge Voltage (1 sec. max.)
Start-Up Voltage
Under Voltage Shutdown
Reverse Polarity Input Current
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI
All Models
A
mW
mW
Compliance to EN 55022,class A and FCC part 15,class A
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Short Circuit Protection
25% Load Step Change
Over Line, Load & Temp.
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=25% to 100%
Conditions
Min.
---
---
---
---
---
---
---
---
---
---
Continuous
Typ.
±1.0
±1.0
±0.3
±0.5
30
---
---
100
±3
±0.01
Max.
±2.0
±2.0
±0.5
±0.75
50
75
15
300
±5
±0.02
Unit
%
%
%
%
mV
P-P
mV
P-P
mV rms
uS
%
%/℃
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Conditions
60 Seconds
500 VDC
100KHz, 1V
Min.
1500
1000
---
---
1,000,000
Typ.
---
---
250
300
---
Max.
---
---
420
---
---
Unit
VDC
MΩ
pF
KHz
Hours
Input Fuse
5V Input Models
1000mA Slow-Blow Type
12V Input Models
500mA Slow-Blow Type
24V Input Models
250mA Slow-Blow Type
48V Input Models
120mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
---
Conditions
Ambient
Min.
-40
---
-55
---
Free-Air convection
260
℃
Max.
+80
+90
+105
95
Unit
℃
℃
℃
% rel. H
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/08/11 REV:6
Page 2 of 4
®
MDW1000 SERIES
DC/DC CONVERTER 2W,
DIP-Package
Power Derating Curve
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
Ripple & Noise measurement bandwidth is 0-20 MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however, they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
Specifications subject to change without notice.
Package Specifications
Mechanical Dimensions
0.5 [0.02]
8.0 [0.31]
Output Power (%)
0.50 [0.02]
Pin Connections
Pin
Single Output
1
-Vin
7
NC
8
NC
9
+Vout
10
-Vout
16
+Vin
NC: No Connection
Dual Output
-Vin
NC
Common
+Vout
-Vout
+Vin
1
7
8
10.16 [0.40]
10
9
[0.15]
13.7 [0.54]
Bottom View
16
3.8
23.8 [0.94]
Physical Characteristics
Case Size
Case Material
Weight
:
:
:
23.8x13.7x8.0 mm (0.94x0.54x0.31 inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
5.1g
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/08/11 REV:6
Page 3 of 4
[0.07]
1.77
3.0
[0.12]
15.24 [0.60]
2.54
[0.10]
►All
dimensions in mm (inches)
►Tolerance:
X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
diameter
0.5 ±0.05 (0.02±0.002)
®
Test Configurations
Input Reflected-Ripple Current Test Setup
MDW1000 SERIES
DC/DC CONVERTER 2W,
DIP-Package
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance.
Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
Battery
+
Lin
Current
Probe
+Vin
+Out
Load
DC / DC
Converter
-Vin
-Out
Cin
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
Single Output
DC / DC
Converter
-Vin
-Out
+Out
Copper Strip
Cout
Copper Strip
Resistive
Scope
Load
+Vin
Dual Output
DC / DC
Converter
-Vin
+Out
Com.
-Out
Copper Strip
Cout
Copper Strip
Cout
Copper Strip
Scope
Scope
Resistive
Load
Design & Feature Considerations
Maximum Capacitive Load
The MDW1000 series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup.
By using a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 8.2uF for the 5V input devices, a 3.3uF for the 12V input devices
and a 1.5uF for the 24V and 48V devices, capacitor mounted close to the power module helps ensure stability of the unit.
+
DC Power
Source
-
+
Cin
-Vin
-Out
+Vin
DC / DC
Converter
+Out
Load
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3uF capacitors at the output.
+
DC Power
Source
-
-Vin
+Vin
Single Output
DC / DC
Converter
-Out
+Out
+
DC Power
Source
-
+Vin
+Out
Dual Output
DC / DC
Com.
Converter
Cout
Cout
Load
Load
Cout
Load
-Vin
-Out
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT