W1G200-HH01-52
EC axial compact fan
sickled blades (S series)
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Nominal data
Type
Motor
W1G200-HH01-52
M1G074-BF
VDC
VDC
Hz
min
-1
W
A
Pa
°C
°C
48
36 .. 57
-
fa
2950
55
1.3
120
- 25
+60
Nominal voltage
Nominal voltage range
Frequency
Type of data definition
Speed
Power input
Current draw
Max. back pressure
Min. ambient temperature
Max. ambient temperature
ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit
Subject to alterations
Item no. 50290-5-9980 · Revision 76790 · Release 2012-08-27 · Page 1 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W1G200-HH01-52
EC axial compact fan
sickled blades (S series)
Technical features
Mass
Size
Surface of rotor
Material of blades
Material of wall ring
Number of blades
Direction of air flow
Direction of rotation
Type of protection
Insulation class
Humidity class
Max. permissible ambient motor
temp. (transp./ storage)
Min. permissible ambient motor
temp. (transp./storage)
Mounting position
Condensate discharge holes
Operation mode
Motor bearing
Technical features
2.15 kg
200 mm
Coated in black
Sheet steel, coated in black
Die-cast aluminium
9
"V"
Counter-clockwise, seen on rotor
IP 42
"B"
F0
+ 80 °C
- 40 °C
Any
None
S1
Ball bearing
- Control input 0-10 VDC / PWM
- Line undervoltage detection
- Motor current limit
- Soft start
Acc. to EN 61000-6-2 (industrial environment)
Acc. to EN 55022 (Class B)
Via terminal strip
Reverse polarity and locked-rotor protection
I (if protective earth is connected by customer)
EN 60335-1
CCC; UL 1004-1; CSA C22.2 Nr.77
EMC interference immunity
EMC interference emission
Electrical leads
Motor protection
Protection class
Product conforming to standard
Approval
Item no. 50290-5-9980 · Revision 76790 · Release 2012-08-27 · Page 2 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W1G200-HH01-52
EC axial compact fan
sickled blades (S series)
Product drawing
1
1.1
1.2
1.3
1.4
2
Connection: terminal strip with 5 terminals.
UN +48 VDC (red)
GND (blue)
DUE (white)
0-10 VDC (yellow)
Direction of air flow "V"
Item no. 50290-5-9980 · Revision 76790 · Release 2012-08-27 · Page 3 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W1G200-HH01-52
EC axial compact fan
sickled blades (S series)
Connection screen
Line
1
1
1
1
No.
1
2
3
4
Signal
Un +48 VDC
0-10 VDC
Tach
GND
Colour
red
yellow
white
blue
Function / assignment
Power supply 48 VDC, residual ripple 3.5 %
Control input Re > 100 K
Speed monitoring output, 3 pulses per rotation, Isink max = 10 mA
Reference mass
Item no. 50290-5-9980 · Revision 76790 · Release 2012-08-27 · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W1G200-HH01-52
EC axial compact fan
sickled blades (S series)
Charts: Air flow
Druck p f s[Pa]für Rho=1,2kg/m^3
320
310
300
290
280
270
260
250
240
230
220
210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0
100
200
300
qv[cfm]
400
500
600
700
800
1,25
1,2
1,15
1,1
1,05
1
0,95
0,9
0,85
0,8
0,75
0,7
0,65
0,6
0,55
Measurement: LU-122619
Measurement: LU-122613
Measurement: LU-122617
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
4
8
7
12
11
6
10
]
Pa
f [
ps
]
Pa
f [
ps
]
[Pa
f
ps
0,5
0,45
3
0,4
0,35
0,3
0,25
2
0,2
0,15
0,1
0,05
1.300
0
1.400
9
5
1
0
100
200
300
400
500
600
700
800
qv[m^3/h]
900
1.000
1.100
1.200
Measured values
U
V
1
2
3
4
5
6
7
8
9
10
11
12
57
57
57
57
48
48
48
48
36
36
36
36
n
min
-1
3320
3225
3130
3070
2950
2880
2810
2755
2500
2420
2360
2310
P
ed
W
72
76
80
83
55
56
59
61
34
35
36
37
I
A
1.42
1.49
1.57
1.62
1.30
1.31
1.38
1.42
1.11
1.14
1.16
1.18
qv
m
3
/h
1205
1090
935
775
1090
985
850
700
900
815
705
580
p
fs
Pa
0
50
97
123
0
40
80
100
0
28
55
69
U = Supply voltage · n = Speed · P
ed
= Power input · I = Current draw · qv = Air flow · p
fs
= Pressure increase
Item no. 50290-5-9980 · Revision 76790 · Release 2012-08-27 · Page 5 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
p fs_E[IN H2O]
p s[Pa]
f